Sale!

STBART0200K – standard analog input kit STB

Original price was: $280.00.Current price is: $170.00.

The STBART0200K features two independent analog input channels, allowing it to process signals from two separate analog devices simultaneously.

1 in stock

Free shipping on orders over $5000!

  • Check Mark Satisfaction Guaranteed
  • Check Mark No Hassle Refunds
  • Check Mark Secure Payments
GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
Category:

Description

Main
range of product Modicon STB distributed an I/O solution.
product or component type Standard analog input kit.
kit composition STBART0200 module.
STBXTS1100, 6-terminal screw-type connector.
STBXBA1000 base.
STBXTS2100, 6-terminal spring clamp connector.
analogue input type Voltage: +/- 80 mV.
Temperature probe -100…+260 .°C Cu 10 2, 3 or 4 wires IEC.
Temperature probe -100…+450. °C Pt 100 2, 3 or 4 wires US/JIS.
Temperature probe -100…+450 .°C Pt 1000 2, 3 or 4 wires US/JIS.
Temperature probe -200…+850. °C Pt 100 2, 3 or 4 wires IEC.
Temperature probe -200…+850.°C Pt 1000 2, 3 or 4 wires IEC.
Temperature probe -60…+180 °C Ni 100 2, 3 or 4 wires IEC.
Temperature probe -60…+180. °C Ni 1000 2, 3 or 4 wires IEC..
Thermocouple +130… +1820. °C thermocouple B.
Thermocouple: -200…+760 °C thermocouple J.
Thermocouple: -270…+1000 °C thermocouple E.
Thermocouple: -270…+1370 °C thermocouple K.
Thermocouple -270…+400 °C thermocouple T.
Thermocouple: -50…+1665 °C thermocouple R.
Thermocouple: -50…+1665 °C thermocouple S.
analogue input number 2
analogue input resolution 15 bits + sign
type of filter Single low-pass input filter at 25 Hz.
Complementary
absolute maximum input +/- 7.5 V DC.
cold swapping Yes
hot swapping fallback Yes for standard NIMs.
fallback status State 0 basic NIMs
User-configurable standard NIMs.
data format EN 61131-2.
IEC 61131-2.
input impedance 10 MOhm +/- 80 mV.
maximum supply current for sensors 100 mA per input channel.
protection type Short-circuit protection.
absolute accuracy error +/- 0.1% of full scale 25 °C internal.
+/- 0.15 % of full-scale 25 °C external.
insulation between channels and logic bus 1500 V for 1 minute.
addressing requirement 1 word for cold-junction compensation.
2 input words.
product compatibility Mounting base: STBXBA1000.
Power distribution module STBPDT3100/3105.
[Us] rated supply voltage 24 V DC
supply Power distribution module.
current consumption 30 mA at 5 V DC for the logic bus.
measurement resolution 0.01 mV voltage.
0.1 °C or 0.1 °F temperature probe.
0.1 °C or 0.1 °F thermocouple.
conversion time 150 ms voltage, 60 Hz.
170 ms voltage, 50 Hz.
180 ms temperature probe, 60 Hz, 2 or 4 wires.
200 ms temperature probe, 50 Hz, 2 or 4 wires.
210 ms thermocouple with internal cold-junction; compensation: 60 Hz.
230 ms thermocouple with internal cold-junction.; 50 Hz compensation.
300 ms temperature probe, 60 Hz, 3 wires.
340 ms temperature probe, 50 Hz, 3 wires.
360 ms thermocouple with external cold-junction., 60 Hz compensation.
400 ms thermocouple with external cold-junction.; 50 Hz compensation.
maximum wiring resistance 20 Ohm Cu 10 IEC/US/JIS 2 or 3 wires.
20 Ohm Ni 100 IEC/US/JIS 2 or 3 wires.
20 Ohm Pt 100 IEC/US/JIS 2 or 3 wires.
200 Ohm Ni 1000 IEC/US/JIS 2 or 3 wires.
200 Ohm Pt 1000 IEC/US/JIS 2 or 3 wires.
50 Ohm Cu 10 IEC/US/JIS 4 wires.
50 Ohm Ni 100 IEC/US/JIS 4 wires.
50 Ohm Pt 100 IEC/US/JIS 4 wires.
500 Ohm Ni 1000 IEC/US/JIS 4 wires.
500 Ohm Pt 1000 IEC/US/JIS 4 wires.
measurement accuracy +/- 1 °C Ni 100 25 °C external.
+/- 1 °C Ni 100 25 °C internal.
+/- 1 °C Ni 1000 25 °C external.
+/- 1 °C Ni 1000 25 °C internal.
+/- 1 °C Pt 100 25 °C internal.
+/- 1 °C Pt 1000 25 °C internal.
+/- 1.75 °C thermocouple B with external cold.
junction compensation at 25 °C.
+/- 1.75 °C thermocouple E with external cold-junction compensation at 25 °C.
+/- 1.75 °C thermocouple J with external cold-junction compensation at 25 °C.
+/- 1.75 °C thermocouple K with external cold-junction compensation at 25 °C.
+/- 1.75 °C thermocouple R with external cold-junction compensation at 25 °C.
+/- 1.75 °C thermocouple S with external cold-junction compensation at 25 °C.
+/- 1.75 °C thermocouple T with external cold-junction compensation at 25 °C.
+/- 2 °C Pt 100 25 °C external.
+/- 2 °C Pt 1000 25 °C external.
+/- 2.85 °C thermocouple B with external cold-junction compensation at 60 °C.
+/- 2.85 °C thermocouple E with external cold-junction compensation at 60 °C.
+/- 2.85 °C thermocouple J with external cold-junction compensation at 60 °C.
+/- 2.85 °C thermocouple K with external cold-junction compensation at 60 °C.
+/- 2.85 °C thermocouple R with external cold-junction compensation at 60 °C.
+/- 2.85 °C thermocouple S with external cold-junction compensation at 60 °C.
+/- 2.85 °C thermocouple T with external cold-junction compensation at 60 °C.
+/- 3.6 °C thermocouple R with internal cold-junction compensation at 25 °C.
+/- 4 °C Cu 10 25 °C external.
+/- 4 °C Cu 10 25 °C internal.
+/- 4 °C thermocouple K with internal cold-junction compensation at 25 °C.
+/- 4.1 °C thermocouple S with internal cold-junction compensation at 25 °C.
+/- 4.2 °C thermocouple R with internal cold-junction compensation at 60 °C.
+/- 4.4 °C thermocouple T with internal cold-junction compensation at 25 °C.
+/- 4.6 °C thermocouple B with internal cold-junction compensation 25 °C.
+/- 4.6 °C thermocouple E with internal cold-junction compensation 25 °C.
+/- 5 °C thermocouple S with internal cold-junction compensation 60 °C.
+/- 5.1 °C thermocouple J with internal cold-junction compensation 25 °C.
+/- 5.5 °C thermocouple K with internal cold-junction compensation 60 °C.
+/- 6.4 °C thermocouple T with internal cold-junction compensation at 60 °C.
+/- 6.8 °C thermocouple B with internal cold-junction compensation at 60 °C.
+/- 6.8 °C thermocouple E with internal cold-junction compensation at 60 °C.
+/- 7 °C thermocouple J with internal cold-junction compensation at 60 °C.
marking CE
overvoltage category II
status LED 1 LED (green) module status (RDY).
1 LED (red) module error (ERR).
Environment
product certifications UL
FM Class 1 Division 2.
CSA.
ATEX Cat 3G.
C-Tick
pollution degree conforming to IEC 60664-1.
operating altitude <= 2000 m.
IP degree of protection IP20 conforms to EN 61131-2 class 1.
ambient air temperature for operation 0…70 °C.
ambient air temperature for operation 32–140 °F without derating.
ambient air temperature for storage -40…85 °C without derating.
ambient air temperature for storage -40–185 °F without derating.
relative humidity 95 % at 60 °C without condensation.
vibration resistance +/-0.35 mm at 10…58 Hz.
3 gn at 58…150 Hz on 35 x 7.5 mm symmetrical DIN rail.
5 gn at 58…150 Hz on 35 x 15 mm symmetrical DIN rail.
shock resistance 30 gn for 11 ms, conforming to IEC 88 reference 2-27.
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 136.0 g
Package 1 Height 2.5 cm
Package 1 width 8 cm
Package 1 Length 13 cm
Unit Type of Package 2 S02
Number of Units in Package 2 42
Package 2 Weight 6.1 kg
Package 2 Height 15 cm
Package 2 width 30 cm
Package 2 Length 40 cm