Main
RANGE OF PRODUCT Sepam Series 40.
Sepam Series 80 NPP.
Sepam series 60.
Sepam Series 80.
DEVICE SHORT NAME ACE850TP

Complementary
COMMUNICATION PORT PROTOCOLARP network: S-LAN and E-LAN interfaces: 2 Ethernet ports: 10/100BASE-TX.


FTP network: S-LAN and E-LAN interfaces: 2 Ethernet ports 10/100BASE-TX.


HTTP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX.


IEC 61850 network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX.


Modbus RTU network: S-LAN and E-LAN.

interface: 2 Ethernet ports (10/100BASE-TX).


Modbus TCP/IP network: S-LAN and E-LAN.

interface: 2 Ethernet ports (10/100BASE-TX).


RSTP 801.1d 2004 network: S-LAN and E-LAN.

interface: 2 Ethernet ports (10/100BASE-TX).


SNMP network: S-LAN and E-LAN interfaces: 2.

Ethernet ports 10/100BASE-TX.


SNTP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX.

 

LOCAL SIGNALLINGGreen LED1 for energized (front face).


Green LED2 for communication status OK (front face).


Green LED3 off for port 2 Ethernet 10 Mbit/s (front face).


Green LED3 on for port 2 Ethernet 100 Mbit/s (front face).


Green LED4 flashing for port 2 Ethernet sending data and receiving data (front face).


Green LED5 off for port 1 Ethernet 10 Mbit/s (front face).


Green LED5 on for port 1 Ethernet 100 Mbit/s (front face).


Green LED6 flashing for port 1 Ethernet sending data and receiving data (front face).


Red LED1 flashing for not set up or not base-unit connected (front face).


Red LED1 is off for de-energized (front face).


Red LED1 remains ON for fault (front face).

 

[US] RATED SUPPLY VOLTAGE110…240 V AC tolerance: -20…10%.
24…250 V DC tolerance: 20…10%.
MOUNTING MODEFixed.
MOUNTING SUPPORTSymmetrical DIN rail.
HEIGHT127 mm
WIDTH171 mm
DEPTH58 mm
PRODUCT WEIGHT0.4 kg
MECHANICAL ROBUSTNESSEarthquakes in operation (level 2): 1 Gn. (vertical axes) conforming to IEC 60255-21-3.


Earthquakes in operation (level 2): 2 Gn.

(horizontal axes) conforming to IEC 60255-21-3.


Jolts de-energized (level 2): 20 Gn/16 ms., conforming to IEC 60255-21-2.


Shocks de-energized (level 2): 30 Gn/11 ms., conforming to IEC 60255-21-2.


Shocks in operation (level 2): 10 Gn/11 ms., conforming to IEC 60255-21-2.


Vibrations de-energized (level: 2) : 2 Gn, 10. Hz, 150 Hz, conforming to IEC 60255-21-1.


Vibrations in operation (level: 2) : 1 Gn, 10 Hz, 150 Hz, conforming to IEC 60255-21-1.


Vibrations in operation (level: Fc): 2 Hz… 13.2.

Hz, a = +/- 1 mm, conforming to IEC 60068-2-6.

 

MAXIMUM CABLE DISTANCE BETWEEN DEVICES<100 m.
AUXILIARY CONNECTION TERMINALFunctional earth: ring lug, 1 pin(s), 1 cable(s), tinned copper braid, 4 mm2.


Protective earth: screw-type connector 1 pin(s) 1 cable(s) wire 2.5 mm² <3 m.


Supply: screw-type connector, 3 pin(s), 1 cable(s), wire, 0.5–2.5 mm2.


Supply: screw-type connector, 3 pin(s), 1 cable(s), 1.5 mm2.


Supply: screw-type connector, 3 pin(s), 1 cable(s), 2.5 mm2.


Supply: screw-type connector, 3 pins, 2 cable(s), wire, 0.5… 1 mm2.


Supply: screw-type connector, 3 pins, 2 cable(s), 1 mm2.


Supply: screw-type connector, 4 pin(s), 1 cable(s), wire, 0.5…2.5 mm2.


Supply: screw-type connector, 4 pins, 1 cable(s), wire, 1.5 mm2.


Supply: screw-type connector, 4 pin(s), 1 cable(s), wire, 2.5 mm2.


Supply: screw-type connector, 4 pins, 2 cable(s), wire, 0.5… 1 mm2.


Supply: screw-type connector, 4 pins, 2 cable(s), 1 mm².

WIRE STRIPPING LENGTHSupply: 8 mm.
Environment
ELECTROMAGNETIC COMPATIBILITY1 MHz damped oscillating wave.

(immunity tests-conducted disturbances), 2.5 kV MC and MD, conforming to ANSI C37.90.1


1 MHz damped oscillating wave.

(immunity tests-conducted disturbances), III, 2.5 kV MC, 1 kV MD, conforming to IEC 60255-22-1.


100 kHz damped oscillating wave.

(immunity tests-conducted disturbances), 2.5 kV MC, 1 kV MD, conforming to IEC 61000-4-12.


Conducted disturbance emission.

(emission tests), conforming to IEC 60255-25.


Conducted disturbance emission.

(emission tests), B, conforming to EN 55022.


Disturbing field emission.

(emission tests), conforming to IEC 60255-25.


Disturbing field emission.

(emission tests), A, conforming to EN 55022.


Electrostatic discharge: (immunity tests-radiated disturbances).

8 kV air, 4 kV contact, conforming to ANSI C37.90.3.


Electrostatic discharge.

(immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2.


Fast transient bursts

(immunity tests-conducted disturbances), 4 kV, 2.5 kHz, conforming to ANSI C37.90.1.


Fast transient bursts

(immunity tests-conducted disturbances), A or B, 4 kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4.


Fast transient bursts

(immunity tests-conducted disturbances), IV, 4 kV, 2.5 kHz, conforming to IEC 61000-4-4.


Immunity to conducted RF disturbances

(immunity tests-conducted disturbances), 10 V, conforming to IEC 60255-22-6.


Immunity to magnetic fields at network frequency: .(immunity tests-radiated disturbances).

 

 IV, 30 A/m (continuous)-300 A/m (13 s), conforming to IEC 61000-4-8.


Immunity to radiated fields

(immunity tests-radiated disturbances), 10 V/m, 80 MHz, 1 GHz, conforming to IEC 60255-22-3.


Immunity to radiated fields

(immunity tests-radiated disturbances), 35 V/m, 25 MHz, 1 GHz, conforming to ANSI C37.90.2 (1995).


Immunity to radiated fields

(immunity tests-radiated disturbances), III, 10 V/m, 80 MHz, 2 GHz, conforming to IEC 61000-4-3.


Surges

(immunity tests-conducted disturbances), III, 2 kV MC, 1 kV MD, conforming to IEC 61000-4-5
Voltage interruptions.

(immunity tests-conducted disturbances), 100%, 10 ms, conforming to IEC 60255-11.

CLIMATIC WITHSTANDInfluence of corrosion/gaz test 4 (in operation).

21 days, 75% RH, 25 °C, 0.01 ppm H2S, 0.2 ppm. S02, 0.02 ppm NO2, and 0.01 ppm Cl2 conforming to IEC 60068-2-60.
Continuous exposure to damp heat (in operation).

Ca: 10 days, 93% RH, 40 °C (104 °F), conforming to IEC 60068-2-3.


Continuous exposure to damp heat (in storage)

Ca: 56 days, 93% RH, 40 °C (104 °F), conforming to IEC 60068-2-3.


Exposure to cold (in operation).

Ab: -25 °C (- 13 °F) conforming to IEC 60068-2-1.


Exposure to cold (in storage) : Ab: -25 °C (- 13 °F) conforming to IEC 60068-2-1.
Exposure to dry heat (in operation) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2.


Exposure to dry heat (in storage) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2.


Influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C (- 13 °F), 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60.


Salt mist (in operation) : Kb/2, conforming to IEC 60068-2-52.


Temperature variation with specified variation rate (in operation).

Nb: -25 °C to 70 °C (- 13 °F to 158 °F) 5 °C/min (41 °F/min), conforming to IEC 60068-2-14.

AMBIENT AIR TEMPERATURE FOR OPERATION-25…70 °C.
Packing Units
UNIT TYPE OF PACKAGE 1PCE
NUMBER OF UNITS IN PACKAGE 11
PACKAGE 1 HEIGHT9.800 cm
PACKAGE 1 WIDTH16.700 cm
PACKAGE 1 LENGTH19.800 cm
PACKAGE 1 WEIGHT721 g
UNIT TYPE OF PACKAGE 2S03
NUMBER OF UNITS IN PACKAGE 26
PACKAGE 2 HEIGHT30.000 cm
PACKAGE 2 WIDTH30.000 cm
PACKAGE 2 LENGTH40.000 cm
PACKAGE 2 WEIGHT4.733 kg
UNIT TYPE OF PACKAGE 3P12
NUMBER OF UNITS IN PACKAGE 348
PACKAGE 3 HEIGHT44.500 cm
PACKAGE 3 WIDTH80.000 cm
PACKAGE 3 LENGTH120.000 cm
PACKAGE 3 WEIGHT49.784 kg