LC1D25BNE – TeSys D contactor 3P 25A AC-3 up to 440V
Original price was: $58.00.$45.00Current price is: $45.00.
The LC1D25BNE TeSys D contactor from Schneider Electric is a three-pole (3P) device rated for AC-3 duty with a current capacity of 25A.
6 in stock
Free shipping on orders over $5000!
- Satisfaction Guaranteed
- No Hassle Refunds
- Secure Payments
Description
range | TeSys. TeSys Deca. |
---|---|
range of product | TeSys D. TeSys Deca. |
product or component type | Contactor. |
device short name | LC1D. |
contactor application | Resistive load. Motor control. |
utilisation category | AC-3. AC-1. AC-3e. |
poles description | 3P. |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz. |
[Ie] rated operational current | 25 A (at <60 °C) at <= 440 V AC-3 for power circuit. 40 A (at <60 °C) at <= 440 V AC-1 for power circuit. 25 A (at <60 °C) at <= 440 V AC-3e for power. circuit. |
[Uc] control circuit voltage | 24…60 V AC 50/60 Hz. 24…60 V DC. |
motor power kW | 5.5 kW at 220…230 V AC 50 Hz (AC-3). 11 kW at 380…400 V AC 50 Hz (AC-3). 11 kW at 415 V AC 50 Hz (AC-3). 11 kW at 440 V AC 50 Hz (AC-3). 15 kW at 500 V AC 50 Hz (AC-3). 15 kW at 660…690 V AC 50 Hz (AC-3). 5.5 kW at 220…230 V AC 50 Hz (AC-3e). 11 kW at 380–400 V AC, 50 Hz (AC-3e). 11 kW at 415 V AC 50 Hz (AC-3e). 11 kW at 440 V AC 50 Hz (AC-3e). 15 kW at 500 V AC 50 Hz (AC-3e). 15 kW at 660…690 V AC 50 Hz (AC-3e). |
---|---|
motor power hp | 2 hp at 115 V AC 60 Hz for 1-phase motors. 3 hp at 230/240 V AC 60 Hz for 1-phase motors. 7.5 hp at 200/208 V AC 60 Hz for 3-phase motors. 7.5 hp at 230/240 V AC 60 Hz for 3-phase motors. 15 hp at 460/480 V AC 60 Hz for 3-phase motors. 20 hp at 575/600 V AC 60 Hz for 3-phase motors. |
compatibility code | LC1D. |
pole contact composition | 3 NO. |
protective cover | With. |
[Ith] conventional free air thermal current | 10 A (at 60 °C) for the signaling circuit. 40 A (at 60 °C) for the power circuit. |
Irms rated making capacity | 140 A AC for signalling circuits conforming to IEC 60947-5-1. 250 A DC for the signaling circuit conforming to IEC 60947-5-1. 450 A at 440 V for a power circuit conforming to IEC 60947. |
rated breaking capacity | 450 A at 440 V for a power circuit conforming to IEC 60947. |
[Icw] rated short-time withstand current | 100 A – 1 s for the signaling circuit. 120 A to 500 ms for the signaling circuit. 140 A to 100 ms for the signaling circuit. 50 A, 40 °C, 10 min for the power circuit. 120 A, 40 °C, 1 min for the power circuit. 240 A, 40 °C, 10 s for the power circuit. 380 A, 40 °C, 1 s for the power circuit. |
associated fuse rating | 10 A gG for the signaling circuit conforming to IEC 60947-5-1. 63 A gG at <= 690 V coordination type 1 for power circuit. 40 A gG at <= 690 V coordination type 2 for the power circuit. |
average impedance | 2 mOhm with 40 A and 50 Hz for a power circuit. |
power dissipation per pole | 3.2 W AC-1. 1.25 W AC-3. 1.25 W AC-3e. |
[Ui] rated insulation voltage | Power circuit: 690 V, conforming to IEC 60947-4-1. Signaling circuit: 690 V, conforming to IEC 60947-1. |
overvoltage category | III |
pollution degree | 3 |
[Uimp] rated impulse withstand voltage | 6 kV, conforming to IEC 60947. |
safety reliability level | B10d = 1369863 cycles of contactor with a nominal load conforming to EN/ISO 13849-1. B10d = 20000000 cycles of contactor with mechanical load conforming to EN/ISO 13849-1. |
mechanical durability | 15 Mcycles. |
electrical durability | 2 Mcycles 21 A AC-3 at Ue <= 440 V. 0.9 Mcycles 40 A AC-1 at Ue <= 440 V. 2 Mcycles 21 A AC-3e at Ue <= 440 V. |
control circuit type | AC/DC at 50/60 Hz AC/DC electronic. |
coil technology | Built-in bidirectional peak limiting. |
control circuit voltage limits | <= 0.1 Uc (-40…70 °C): drop-out AC/DC. 0.85…1.1 Uc (-40…60 °C): operational AC. 0.8…1.1 Uc (-40…60 °C): operational DC. 1…1.1 Uc (60…70 °C): operational AC/DC. |
inrush power in VA | 15 VA, 50/60 Hz (at 20 °C). |
inrush power in W | 14 W (at 20 °C). |
hold-in power consumption in VA | 0.9 VA 50/60 Hz (at 20 °C). |
hold-in power consumption in W | 0.6 W at 20 °C |
heat dissipation | 0.6 W at 50/60 Hz. |
operating time | 45–55 ms. closing. 20…90 ms opening. |
maximum operating rate | 3600 cyc/h, 60 °C. |
connections – terminals | Control circuit: screw clamp terminals 1 1/4 mm²; cable stiffness: flexible without cable end. Control circuit: screw clamp terminals 2 1/4 mm²; cable stiffness: flexible without cable end. Control circuit: screw clamp terminals 1 1/4 mm²; cable stiffness: flexible with the cable end. Control circuit: screw clamp terminals 2 1…2.5 mm²; cable stiffness: flexible with cable end. Control circuit: screw clamp terminals 1 1/4 mm²; cable stiffness: solid. Control circuit: screw clamp terminals 2 1/4 mm²; cable stiffness: solid. Power circuit: screw clamp terminals 12.5…10 mm²; cable stiffness: flexible without cable end. Power circuit: screw clamp terminals 2 2.5…10 mm²; cable stiffness: flexible without cable end. Power circuit: screw clamp terminals 1 1…10 mm²; cable stiffness: flexible with cable end. Power circuit: screw clamp terminals 2 1.5…6 mm²; cable stiffness: flexible with cable end. Power circuit: screw clamp terminals 1 1.5…10 mm²; cable stiffness: solid. Power circuit: screw clamp terminals 2 2.5…10 mm²; cable stiffness: solid. |
tightening torque | Control circuit: 1.7 N.m. on screw clamp terminals with a screwdriver flat Ø 6 mm. Control circuit: 1.7 N.m. on screw clamp terminals with screwdriver Philips No. 2. Power circuit: 2.5 N.m. on screw clamp terminals, with screwdriver flat Ø 6 mm. Power circuit: 2.5 N.m. on screw clamp terminals with screwdriver Philips No. 2. Power circuit: 2.5 N.m. on screw clamp terminals with screwdriver pozidriv No. 2 M4. Control circuit: 1.7 N.m. on screw clamp terminals, with screwdriver pozidriv No. 2 M3.5. |
auxiliary contact composition | 1 NO + 1 NC. |
auxiliary contacts type | Type mechanically linked: 1 NO + 1 NC, conforming to IEC 60947-5-1. type mirror contact 1 NC, conforming to IEC 60947-4-1. |
signalling circuit frequency | 25…400 Hz. |
minimum switching voltage | 17 V for the signaling circuit. |
minimum switching current | 5 mA for the signaling circuit. |
insulation resistance | > 10 MOhm for the signaling circuit. |
non-overlap time | 1.5 ms on de-energization between NC and NO contact. 1.5 ms on energization between NC and NO contact. |
mounting support | Plate. Rail. |
standards | EN/IEC 60947-4-1. EN/IEC 60947-5-1. UL 60947-4-1. CSA C22.2 No. 60947-4-1. IEC 60335-1. |
---|---|
product certifications | CCC CSA EAC UL KC DNV-GL LROS (Lloyds Register of Shipping). UKCA |
IP degree of protection | IP20 front face conforms to IEC 60529. |
climatic withstand | Conforming to IACS E10 exposure to damp heat. conforming to IEC 60947-1 Annex Q. category D exposure to damp heat. |
permissible ambient air temperature around the device | -40…60 °C 60…70 °C with derating. |
operating altitude | 0…3000 m |
fire resistance | 850 °C, conforming to IEC 60695-2-1. |
flame retardance | V1 conforms to UL 94. |
mechanical robustness | Vibrations contactor open (2 Gn, 5…300 Hz). Vibrations contactor closed (4 Gn, 5…300. Hz) Shocks contactor closed (15 Gn for 11 ms). Shocks contactor open (8 Gn for 11 ms). |
height | 85 mm. |
width | 45 mm. |
depth | 92 mm. |
net weight | 0.433 kg. |
Unit Type of Package 1 | PCE. |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 5.5 cm. |
Package 1 Width | 9.5 cm. |
Package 1 Length | 12.0 cm. |
Package 1 Weight | 460.0 g. |
Unit Type of Package 2 | S02. |
Number of Units in Package 2 | 15 |
Package 2 Height | 15.0 cm. |
Package 2 Width | 30.0 cm. |
Package 2 Length | 40.0 cm. |
Package 2 Weight | 7.204 kg. |