ATV312H075S6 Schneider Electric
$1,892.00 Original price was: $1,892.00.$1,455.00Current price is: $1,455.00.
The Schneider Electric ATV312H075S6 is a versatile variable frequency drive (VFD) designed for industrial applications.
45 in stock
Free shipping on orders over $5000!
- Satisfaction Guaranteed
- No Hassle Refunds
- Secure Payments
Categories: PAC & PLC, soft starter
Description
| Range of product | Altivar 312. |
|---|---|
| Product or component type | Variable speed drive. |
| Product destination | Asynchronous motors. |
| Product specific application | Simple machine. |
| Assembly style | With heat sink. |
| Component name | ATV312. |
| Motor power kW | 0.75 kW. |
| Motor power hp | 1 hp |
| [Us] rated supply voltage | 525…600 V – 15…10 %. |
| Supply frequency | 50…60 Hz – 5…5 %. |
| Network number of phases | 3 phases. |
| Line current | 2.8 A at 525 V, Isc = 5 kA. 2.4 A at 600 V. |
| EMC filter | Without EMC filter. |
| Apparent power | 2.5 kVA. |
| Maximum transient current | 2.6 A for 60 s. |
| Power dissipation in W | 36 W at nominal load. |
| Speed range | 1…50. |
| Asynchronous motor control profile | Sensorless flux vector control with PWM type motor control signal. Factory set : constant torque. |
| Electrical connection | Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1…LI6 terminal 2.5 mm² AWG 14. L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 5 mm² AWG 10. |
| Supply | Internal supply for logic inputs: 19–30 V, 100 mA. protection type: overload and short-circuit protection Internal supply for reference potentiometer (2.2 to 10 kOhm): 10…10.8 V 10 mA, protection type: overload and short-circuit protection. |
| communication port protocol | Modbus. CANopen. |
| IP degree of protection | IP20 on the upper part without a cover plate. IP21 on connection terminals. IP31 on the upper part. IP41 on the upper part. |
| Option card | Communication card for the CANopen Daisy Chain. Communication card for DeviceNet. Communication card for Fipio. Communication card for Modbus TCP. Communication card for Profibus DP. |
| Supply voltage limits | 446.25…660 V. |
|---|---|
| Prospective line Isc | 5 kA |
| Continuous output current | 1.7 A at 4 kHz. |
| Output frequency | 0…500 Hz |
| Nominal switching frequency | 4 kHz |
| Switching frequency | 2–16 kHz adjustable. |
| Transient overtorque | 170…200% of nominal motor torque. |
| Braking torque | 150% during 60 s with a braking resistor. 100% with the braking resistor continuously. 15% without a braking resistor. |
| Regulation loop | Frequency PI regulator. |
| Motor slip compensation | Automatic, whatever the load. Adjustable. Suppressable. |
| Output voltage | <= power supply voltage. |
| Tightening torque | Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1… LI6: 0.6 N.m. L1, L2, L3, U, V, W, PA, PB, PA/+, PC/-: 1.2 N.m. |
| insulation | Electrical between power and control. |
| Analogue input number | 3 |
| Analogue input type | AI1 configurable voltage 0…10 V, input voltage 30 V max, impedance: 30000 Ohm. AI2 configurable voltage +/- 10 V, input voltage 30 V max, impedance: 30000 Ohm. AI3 configurable current: 0.20 mA, impedance: 250 Ohm. |
| Sampling duration | AI1, AI2, AI3: 8 ms analog. LI1…LI6: 4 ms discrete. |
| Response time | AOV, AOC, 8 ms for analog. R1A, R1B, R1C, R2A, R2B 8 ms for discrete. |
| Linearity error | +/- 0.2% for output. |
| Analogue output number | 1 |
| Analogue output type | AOC configurable current: 0…20 mA, impedance: 800 Ohm, resolution: 8 bits. AOV configurable voltage: 0…10 V, impedance: 470 Ohm, resolution: 8 bits. |
| Discrete input logic | Logic input not wired (LI1…LI4), < 13 V (state 1). Negative logic (source) (LI1…LI6), > 19 V (state 0). Positive logic (source) (LI1…LI6), < 5 V (state 0), > 11 V (state 1). |
| Discrete output number | 2 |
| Discrete output type | Configurable relay logic: (R1A, R1B, R1C) 1 NO + 1 NC = 100000 cycles. Configurable relay logic: (R2A, R2B) NC: 100000 cycles. |
| Minimum switching current | R1-R2: 10 mA at 5 V DC. |
| Maximum switching current | R1-R2: 2 A at 250 V AC inductive load, cos phi = 0.4, and L/R = 7 ms. R1-R2: 2 A at 30 V DC inductive load, cos phi = 0.4, and L/R = 7 ms. R1-R2: 5 A at 250 V AC resistive load, cos phi = 1, and L/R = 0 ms. R1-R2: 5 A at 30 V DC resistive load, cos phi = 1, and L/R = 0 ms. |
| Discrete input number | 6 |
| Discrete input type | (LI1…LI6) programmable at 24 V, 0…100 mA for PLC, impedance: 3500 Ohm. |
| Acceleration and deceleration ramps | S, U or customized. Linear is adjustable separately from 0.1 to 999.9 s. |
| Braking to standstill | By DC injection. |
| Protection type | Input phase breaks: drive. Line supply overvoltage and undervoltage safety circuits: drive. Line supply phase loss safety function, for three phases supply: drive. Motor phase breaks: drive. Overcurrent between output phases and earth (on power-up only): drive. Overheating protection: drive. Short-circuit between motor phases: drive Thermal protection: motor. |
| Insulation resistance | >= 500 mOhm at 500 V DC for 1 minute. |
| Local signalling | 1 LED (red) for drive voltage. Four 7-segment display units for CANopen bus status. |
| Time constant | 5 ms for reference change. |
| Frequency resolution | Analog input: 0.1…100 Hz Display unit: 0.1 Hz. |
| Connector type | 1 RJ45 for Modbus/CANopen. |
| Physical interface | RS485 multidrop serial link. |
| Transmission frame | RTU. |
| Transmission rate | 10, 20, 50, 125, 250, 500 kbps, or 1 Mbps for CANopen. 4800, 9600, or 19200 bps for Modbus. |
| Number of addresses | 1…127 for CANopen. 1…247 for Modbus. |
| Number of drive | 127 for CANopen. 31 for Modbus. |
| Marking | CE |
| Operating position | Vertical +/- 10 degrees. |
| Height | 143 mm. |
| Width | 107 mm. |
| Depth | 152 mm. |
| Net weight | 1.7 kg. |
| Dielectric strength | 2550 V DC between earth and power terminals. 3600 V AC between control and power terminals. |
|---|---|
| Electromagnetic compatibility | 1.2/50 µs–8/20 µs surge immunity test level 3, conforming to IEC 61000-4-5. Electrical fast transient/burst immunity test level 4 conforms to IEC 61000-4-4. Electrostatic discharge immunity test level 3 conforms to IEC 61000-4-2. Radiated radio-frequency electromagnetic field immunity test level 3 conforms to IEC 61000-4-3. |
| Standards | IEC 61800-3. IEC 61800-5-1. |
| product certifications | DNV. GOST. CSA. C-Tick. UL. NOM. |
| Pollution degree | 2 |
| Protective treatment | TC |
| Vibration resistance | 1 gn (f = 13…150 Hz) conforming to EN/IEC 60068-2-6. 1.5 mm (f = 3…13 Hz) conforming to EN/IEC 60068-2-6. |
| Shock resistance | 15 gn for 11 ms, conforming to EN/IEC 60068-2-27. |
| Relative humidity | 5… 95%% without condensation, according to IEC. 60068-2-3 5% without dripping water, according to IEC 60068-2-3. |
| Ambient air temperature for storage | -25…70 °C. |
| Ambient air temperature for operation | -10…50 °C without derating (with protective cover on top of the drive). -10…60 °C with derating factor (without protective cover on top of the drive). |
| Operating altitude | <= 1000 m without derating. 1000–3000 m with current derating 1 % per 100 m. |
Related products
-
Sale!

140AVO02000 – analog output module Modicon Quantum
$1,719.00Original price was: $1,719.00.$1,322.00Current price is: $1,322.00. -
Sale!

140ATI03000 – analog input module Modicon Quantum
$2,529.00Original price was: $2,529.00.$1,946.00Current price is: $1,946.00. -