140DAO84010 Discrete Output Module Modicon Quantum
Original price was: $2,743.00.$2,110.00Current price is: $2,110.00.
“Control discrete outputs efficiently with the Schneider Electric 140DAO84010 module, offering 32 high-speed channels for Modicon Quantum PLCs.”
6 in stock
Free shipping on orders over $5000!
- Satisfaction Guaranteed
- No Hassle Refunds
- Secure Payments
Description
range of product | Modicon Quantum automation platform |
---|---|
product or component type | AC discrete output modules |
discrete output number | 16 |
discrete output type | Isolated |
---|---|
group of channels | 16 groups of 1 channel |
supply frequency | 47…63 Hz |
maximum voltage drop | 1.5 V |
discrete output voltage | 20…132 V AC |
addressing requirement | 1 output word |
absolute maximum output | 156 V for 10 s AC 200 V during one cycle AC |
maximum load current | 1 mA rms 24 V off state leakage/points 1 mA rms 48 V off state leakage/points 2 mA rms 115 V off state leakage/points 16 A rms per module 4 A rms sum of four points, continuous 4 A rms 20…132 V each point |
surge current | 20 A during 2 cycles per point 30 A during 1 cycle per point 30 A during 3 cycles per point |
dV/dt | 400 V/ms |
response time | <= 0.5 ms at state 0 to state 1 <= 0.5 ms at state 1 to state 0 |
protection type | Internal by RC filter |
power dissipation | 1.85 + (1.1 V x total module load current) |
associated fuse rating | 5 A |
marking | CE |
local signalling | 1 LED (green) for bus communication is present (Active) 1 LED (red) for external fault detected (F) 16 LEDs (green) for input status |
bus current requirement | 350 mA |
module format | Standard |
net weight | 0.485 kg |
product certifications | FM Class 1 Division 2 cUL |
---|---|
standards | UL 508 CSA C22.2 No 142 |
electromagnetic compatibility | Electrostatic discharge immunity test – test level: 4 kV (contact discharge) conforming to IEC 801-2 Electrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to IEC 801-2 Susceptibility to electromagnetic fields – test level: 10 V/m (80…1000 MHz) conforming to IEC 801-3 |
ambient air temperature for operation | 0…60 °C |
ambient air temperature for storage | -40…85 °C |
relative humidity | 95 % without condensation |
operating altitude | <= 5000 m |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 16.3 cm |
Package 1 Width | 4.5 cm |
Package 1 Length | 31.2 cm |
Package 1 Weight | 620.0 g |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 8 |
Package 2 Height | 30.0 cm |
Package 2 Width | 30.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 5.409 kg |
Overview
The Schneider Electric 140DAO84010 is a discrete output module designed for the Modicon Quantum PLC system. This module is essential for controlling and managing discrete outputs in industrial automation applications. It provides reliable and efficient operation of output devices such as relays, actuators, and indicators, making it a critical component in various control and automation systems.
Key Features
Discrete Output Functionality:
The 140DAO84010 module is specifically designed for handling discrete (digital) outputs. It provides binary control signals (on/off) to external devices, allowing for precise and reliable operation of control systems.
High Output Density:
The module features 32 discrete output channels in a compact form factor. This high output density allows for efficient use of panel space and reduces the need for multiple output modules, simplifying system design and reducing costs.
Output Voltage Range:
The 140DAO84010 supports a wide output voltage range, typically accommodating standard industrial voltages such as 24V DC. This versatility ensures compatibility with a broad range of output devices and systems.
Relay and Transistor Outputs:
Depending on the specific model, the module may support various output types, including relay and transistor outputs. This flexibility allows users to select the appropriate output type for their application requirements.
Fast Response Time:
Designed for high-speed applications, the module provides fast response times to changes in output signals. This ensures timely activation and deactivation of output devices, which is essential for real-time control and monitoring.
Electrical Isolation:
The 140DAO84010 provides electrical isolation between the output channels and the internal PLC circuitry. This isolation helps protect the PLC from voltage spikes and other electrical disturbances, ensuring reliable operation.
LED Indicators:
Each output channel is equipped with LED indicators that provide a visual status of the output signal. This feature simplifies troubleshooting and allows for quick verification of output status during operation.
Compact Design:
The module is designed with a compact footprint, allowing it to fit within the tight space constraints of industrial control panels. Its design ensures efficient use of panel space while maintaining high performance.
Mounting Options:
The 140DAO84010 can be mounted on standard DIN rails, providing flexibility in installation and allowing it to be integrated seamlessly into existing control panel configurations.
Applications
The Schneider Electric 140DAO84010 discrete output module is versatile and suitable for a variety of industrial applications, including:
Manufacturing Automation:
In manufacturing environments, the module controls output devices such as solenoids, actuators, and relays used in production lines and machinery management.
Process Control:
The module is used in process control systems to activate and deactivate control devices, such as valves and pumps, based on input signals and process conditions.
Building Automation:
In building management systems, the 140DAO84010 manages output signals to control systems like HVAC units, lighting, and security alarms, contributing to efficient building operations.
Energy Management:
The module controls devices in energy management systems, such as energy meters and control switches, helping to optimize energy usage and improve overall efficiency.
Utilities:
In utilities such as water and wastewater treatment plants, the module is used to control essential equipment and systems, ensuring reliable operation and effective management of resources.
Installation and Configuration
Installation
Power Down the System: Before installing the 140DAO84010, ensure that the PLC system is powered down to prevent electrical hazards and avoid damage to the components.
Mount the Module: Securely mount the module onto a standard DIN rail or mounting panel. Ensure proper alignment with the existing setup and fasten it using the provided screws or clips.
Connect Wiring: Connect the output wiring to the terminal blocks on the module. Follow the wiring diagrams provided in the module’s documentation to ensure correct connections.
Connect to PLC: Integrate the module with the Modicon Quantum PLC system by connecting it to the appropriate backplane or communication interface.
Power Up the System: Once the module is installed and wired, power up the PLC system and verify that the module is functioning correctly.
Configuration
Software Setup: Use Schneider Electric’s configuration software to set up the 140DAO84010 module. Configure output settings, such as output type and voltage range, according to your application requirements.
Addressing: Assign addresses to the output channels to enable proper communication between the module and the PLC. Ensure that the addressing is consistent with the system’s configuration.
Testing: Conduct tests to verify that the module is correctly activating and deactivating output devices. Check for any communication errors or discrepancies and address them as needed.
Calibration: Perform any necessary calibration to ensure that the module accurately processes output signals and provides reliable control of connected devices.
Maintenance
Regular maintenance is essential for ensuring the long-term reliability and performance of the 140DAO84010 module:
Periodic Inspection: Regularly inspect the module and its connections for signs of wear, damage, or loose wiring. Address any issues promptly to prevent potential system failures.
Firmware Updates: Keep the firmware of the PLC and associated modules up to date to benefit from the latest features and improvements. Check for updates from Schneider Electric’s support resources.
Cleaning: Ensure that the module and surrounding area are kept clean and free from dust and debris. Use compressed air to gently clean the module if necessary, avoiding the use of harsh chemicals.
Performance Monitoring: Continuously monitor the performance of the module to detect any potential issues early. Utilize diagnostic tools and software to track system performance and address any anomalies.