Sale!

ATV320U22N4C variable speed drive, Altivar Machine ATV320

Original price was: $526.00.Current price is: $405.00.

23 in stock

Free shipping on orders over $5000!

  • Check Mark Satisfaction Guaranteed
  • Check Mark No Hassle Refunds
  • Check Mark Secure Payments
GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
Category:

Description

Main
range of product Altivar Machine ATV320.
product or component type Variable speed drive.
product specific application Complex machines.
variant Standard version.
With disconnect switch.
format of the drive Compact.
mounting mode Wall mount.
communication port protocol Modbus serial.
CANopen.
option card Communication module, CANopen.
Communication module, EtherCAT.
Communication module, Profibus DP V1.
Communication module, PROFINET.
Communication module, Ethernet Powerlink.
Communication module, EtherNet/IP.
Communication module, DeviceNet.
[Us] rated supply voltage 380…500 V – 15…10 %.
nominal output current 5.5 A
motor power kW 2.2 kW for heavy duty.
EMC filter Class C2 EMC filter integrated.
IP degree of protection IP20.
Complementary
discrete input number 7
discrete input type STO safe torque off, 24 V DC, impedance: 1.5 kOhm
DI1…DI6 logic inputs, 24 V DC (30 V).
DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V).
discrete input logic Positive logic (source).
Negative logic (sink).
discrete output number 3.
discrete output type Open collector DQ+ 0…1 kHz 30 V DC 100 mA.
Open collector DQ- 0…1 kHz 30 V DC 100 mA.
analogue input number 3.
analogue input type AI1 voltage: 0…10 V DC, impedance: 30 kOhm, resolution: 10 bits.
AI2 bipolar differential voltage: +/- 10 V DC,. impedance: 30 kOhm, resolution 10 bits.
AI3 current: 0…20 mA (or 4-20 mA, x-20 mA, 20-x mA. or other patterns by configuration), impedance: 250. Ohm, resolution 10 bits.
analogue output number 1
analogue output type Software-configurable current AQ1: 0…20 mA, impedance 800 Ohm, resolution 10 bits.
Software-configurable voltage AQ1: 0…10 V DC, impedance 470 Ohm, resolution 10 bits.
relay output type Configurable relay logic R1A 1 NO electrical durability: 100000 cycles.
Configurable relay logic R1B 1 NC electrical durability: 100000 cycles.
Configurable relay logic: R1C.
Configurable relay logic R2A 1 NO electrical durability: 100000 cycles.
Configurable relay logic: R2C.
maximum switching current Relay output R1A, R1B, and R1C on resistive load, cos phi = 1: 3 A at 250 V AC.
Relay output R1A, R1B, and R1C on resistive load, cos phi = 1: 3 A at 30 V DC.
Relay outputs R1A, R1B, R1C, R2A, and R2C are inductive. load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC.
Relay outputs R1A, R1B, R1C, R2A, and R2C are inductive. load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC.
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC.
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC.
minimum switching current Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC.
method of access Slave CANopen.
4 quadrant operation possible True
asynchronous motor control profile Voltage/frequency ratio: 5 points.
Flux vector control without sensor, standard.
Voltage/frequency ratio: energy savings, quadratic U/F.
Flux vector control without a sensor is energy-saving.
Voltage/frequency ratio: 2 points.
synchronous motor control profile Vector control without a sensor.
maximum output frequency 0.599 kHz.
transient overtorque 170…200% of nominal motor torque.
acceleration and deceleration ramps Linear.
U
S.
CUS
Ramp switching.
Acceleration/deceleration ramp adaptation.
Acceleration/deceleration automatic stop with DC. injection
motor slip compensation Automatic, whatever the load.
Adjustable 0…300%.
Not available in voltage/frequency ratio (2 or 5 points).
switching frequency 2–16 kHz adjustable.
4…16 kHz with a derating factor.
nominal switching frequency 4 kHz.
braking to standstill By DC injection.
brake chopper integrated True
line current 8.7 A at 380 V (heavy duty).
6.6 A at 500 V (heavy duty).
maximum input current 8.7 A
maximum output voltage 500 V
apparent power 5.7 kVA at 500 V (heavy duty).
network frequency 50…60 Hz
relative symmetric network frequency tolerance 5 %
prospective line Isc 5 kA
base load current at high overload 8.0 A.
power dissipation in W Fan: 74.0 W at 380 V, switching frequency: 4 kHz.
with safety function Safely Limited Speed (SLS) True
with safety function Safe brake management (SBC/SBT) False
with safety function Safe Operating Stop (SOS) False
with safety function Safe Position (SP) False
with safety function Safe programmable logic False
with safety function Safe Speed Monitor (SSM) False
with safety function Safe Stop 1 (SS1) True
with sft fct Safe Stop 2 (SS2) False
with safety function Safe torque off (STO) True
with safety function Safely Limited Position (SLP) False
with safety function Safe Direction (SDI) False
protection type Input phase breaks: drive.
Overcurrent between output phases and earth: drive
Overheating protection: drive.
Short-circuit between motor phases: drive.
Thermal protection: drive.
width 140 mm.
height 184.0 mm.
depth 158.0 mm.
net weight 2.1 kg.
Environment
operating position Vertical +/- 10 degrees.
product certifications CE
ATEX
NOM
GOST
EAC
RCM
KC
marking CE
ATEX
UL
CSA
EAC
RCM
standards EN/IEC 61800-5-1.
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforms to IEC 61000-4-2.
Radiated radio-frequency electromagnetic. field immunity test level 3 conforms to IEC. 61000-4-3.
Electrical fast transient/burst immunity test, level 4, conforming to IEC 61000-4-4.
1.2/50 µs–8/20 µs surge immunity test level 3, conforming to IEC 61000-4-5.
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6.
The voltage dips and interruptions immunity test conforms to IEC 61000-4-11.
environmental class (during operation) Class 3C3 according to IEC 60721-3-3.
Class 3S2 according to IEC 60721-3-3.
maximum acceleration under shock impact (during operation) 150 m/s2 at 11 ms.
maximum acceleration under vibrational stress (during operation) 10 m/s2 at 13…200 Hz.
maximum deflection under vibratory load (during operation) 1.5 mm at 2…13 Hz.
permitted relative humidity (during operation) Class 3K5 according to EN 60721-3.
volume of cooling air 37.7 m3/h.
overvoltage category III
regulation loop Adjustable PID regulator.
speed accuracy +/- 10% of nominal slip 0.2 Tn to Tn.
pollution degree 2
ambient air transport temperature -25…70 °C
ambient air temperature for operation -10…50 °C without derating.
50…60 °C with derating factor.
ambient air temperature for storage -25…70 °C.
Packing Units
Unit Type of Package 1 PCE.
Number of Units in Package 1 1
Package 1 Height 24.5 cm.
Package 1 Width 19.5 cm.
Package 1 Length 26.7 cm.
Package 1 Weight 2.652 kg.
Unit Type of Package 2 P06.
Number of Units in Package 2 12.
Package 2 Height 75 cm.
Package 2 Width 60 cm.
Package 2 Length 80 cm.
Package 2 Weight 45.28 kg.