BMXP341000 processor, Modicon M340, max 512 discrete
Original price was: $551.00.$401.00Current price is: $401.00.
The BMXP341000 processor from Schneider Electric’s Modicon M340 range offers robust control capabilities for industrial automation.
5 in stock
Free shipping on orders over $5000!
- Satisfaction Guaranteed
- No Hassle Refunds
- Secure Payments
Description
range of product |
Modicon M340 automation platform.
|
|
---|---|---|
product or component type |
Processor module.
|
|
number of racks |
2
|
|
number of slots |
11
|
|
discrete I/O processor capacity |
512 I/O single-rack configuration..
|
|
analogue I/O processor capacity |
66 I/O single-rack configuration.
128 I/O multi-rack configuration. |
|
number of application-specific channel |
20
|
|
monitoring |
Diagnostic counters (Modbus).
Event counters Modbus. |
control channels |
Programmable loops.
|
|
---|---|---|
integrated connection type |
Non-isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS232C, transmission mode: 2 twisted shielded pairs at 0.3–19.2 kbit/s full duplex.
Non-isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3–19.2 kbit/s half duplex. Non-isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband,. RS232C, transmission mode: 1 twisted shielded pair at 0.3–19.2 kbit/s half duplex. Non-isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3–19.2 kbit/s half duplex. USB port at 12 Mbit/s. |
|
communication module processor capacity |
2 Ethernet communication modules.
2 AS-Interface module. |
|
number of devices per segment |
0…32 (character mode).
0…32 (Modbus). |
|
number of devices |
point-to-point character mode.
2 point-to-point Modbus. |
|
bus length |
0…10 m serial link non-isolated character mode segment.
0…10 m serial link non-isolated Modbus segment. 0…1000 m serial link isolated character mode segment. 0…1000 m serial link isolated Modbus segment. 0…15 m character mode point-to-point. 0…15 m Modbus point-to-point. |
|
maximum tap links length |
<15 m serial link, non-isolated character mode segment.
<15 m serial link, non-isolated Modbus segment. <40 m serial link isolated character mode segment. <40 m serial link isolated Modbus segment. |
|
number of addresses |
0…248 for character mode.
0…248 for Modbus. |
|
requests |
1 K data bytes per request, character mode.
252 data bytes per RTU request, Modbus. 504 data bytes per ASCII request Modbus. |
|
control parameter |
One CRC on each frame (RTU) Modbus.
One LRC on each frame (ASCII) character mode. One LRC on each frame (ASCII) Modbus. |
|
memory description |
Internal RAM: 2048 kB.
Internal RAM: 128 kB of data. Internal RAM: 1792 kB program constants and symbols. supplied memory card (BMXRMS008MP) provides backups of. programs, constants, symbols and data. |
|
maximum size of object areas |
128 kB unlocated internal data.
16250 %Mi located internal bits. 32464 %MWi internal words located internal data. 32760 %KWi constant words located internal data. |
|
default size of object areas |
128 %KWi constant words located internal data.
256%Mi located internal bits. 512 %MWi internal words located internal data. |
|
application structure |
1 periodic fast task.
32 event tasks. 1 cyclic/periodic master task. There is no auxiliary task. |
|
execution time per instruction |
0.18 µs Boolean.
0.26 µs double-length words. 0.38 µs single-length words. 1.74 µs floating points. |
|
number of instructions per ms |
4.2 Kinst/ms: 65% Boolean + 35% fixed arithmetic.
5.4 Kinst/ms: 100% Boolean. |
|
system overhead |
0.2 ms for fast tasks.
1.05 ms for the master task. |
|
current consumption |
72 mA at 24 V DC.
|
|
supply |
Internal power supply via rack.
|
|
marking |
CE
|
|
status LED |
1 LED (green) processor running (RUN).
1 LED (red) I/O module fault (I/O). 1 LED (red) memory card fault (CARD ERR). 1 LED (red) processor or system fault (ERR). 1 LED (yellow) activity on Modbus (SER COM) |
|
net weight |
0.2 kg
|
ambient air temperature for operation |
0…60 °C.
|
|
---|---|---|
relative humidity |
10…95% without condensation.
|
|
IP degree of protection |
IP20
|
|
protective treatment |
TC
|
|
directives |
2014/35/EU: Low Voltage Directive.
2014/30/EU: electromagnetic compatibility. |
|
product certifications |
CE
UL CSA RCM EAC Merchant Navy. |
|
standards |
EN 61131-2.
EN/IEC 61010-2-201. UL 61010-2-201. CSA C22.2 No. 61010-2-201. IACS E10. EN/IEC 61000-6-5, interface types 1 and 2,. EN/IEC 61850-3, location G. |
|
environmental characteristic |
Hazardous location, class I, division 2.
|