LC1D25BNE – TeSys D contactor 3P 25A AC-3 up to 440V

Original price was: $58.00.Current price is: $45.00.

The LC1D25BNE TeSys D contactor from Schneider Electric is a three-pole (3P) device rated for AC-3 duty with a current capacity of 25A.

6 in stock

Free shipping on orders over $5000!

  • Check Mark Satisfaction Guaranteed
  • Check Mark No Hassle Refunds
  • Check Mark Secure Payments
GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
Category:

Description

Main
range TeSys.
TeSys Deca.
range of product TeSys D.
TeSys Deca.
product or component type Contactor.
device short name LC1D.
contactor application Resistive load.
Motor control.
utilisation category AC-3.
AC-1.
AC-3e.
poles description 3P.
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz.
[Ie] rated operational current 25 A (at <60 °C) at <= 440 V AC-3 for power circuit.
40 A (at <60 °C) at <= 440 V AC-1 for power circuit.
25 A (at <60 °C) at <= 440 V AC-3e for power. circuit.
[Uc] control circuit voltage 24…60 V AC 50/60 Hz.
24…60 V DC.
Complementary
motor power kW 5.5 kW at 220…230 V AC 50 Hz (AC-3).
11 kW at 380…400 V AC 50 Hz (AC-3).
11 kW at 415 V AC 50 Hz (AC-3).
11 kW at 440 V AC 50 Hz (AC-3).
15 kW at 500 V AC 50 Hz (AC-3).
15 kW at 660…690 V AC 50 Hz (AC-3).
5.5 kW at 220…230 V AC 50 Hz (AC-3e).
11 kW at 380–400 V AC, 50 Hz (AC-3e).
11 kW at 415 V AC 50 Hz (AC-3e).
11 kW at 440 V AC 50 Hz (AC-3e).
15 kW at 500 V AC 50 Hz (AC-3e).
15 kW at 660…690 V AC 50 Hz (AC-3e).
motor power hp 2 hp at 115 V AC 60 Hz for 1-phase motors.
3 hp at 230/240 V AC 60 Hz for 1-phase motors.
7.5 hp at 200/208 V AC 60 Hz for 3-phase motors.
7.5 hp at 230/240 V AC 60 Hz for 3-phase motors.
15 hp at 460/480 V AC 60 Hz for 3-phase motors.
20 hp at 575/600 V AC 60 Hz for 3-phase motors.
compatibility code LC1D.
pole contact composition 3 NO.
protective cover With.
[Ith] conventional free air thermal current 10 A (at 60 °C) for the signaling circuit.
40 A (at 60 °C) for the power circuit.
Irms rated making capacity 140 A AC for signalling circuits conforming to IEC 60947-5-1.
250 A DC for the signaling circuit conforming to IEC 60947-5-1.
450 A at 440 V for a power circuit conforming to IEC 60947.
rated breaking capacity 450 A at 440 V for a power circuit conforming to IEC 60947.
[Icw] rated short-time withstand current 100 A – 1 s for the signaling circuit.
120 A to 500 ms for the signaling circuit.
140 A to 100 ms for the signaling circuit.
50 A, 40 °C, 10 min for the power circuit.
120 A, 40 °C, 1 min for the power circuit.
240 A, 40 °C, 10 s for the power circuit.
380 A, 40 °C, 1 s for the power circuit.
associated fuse rating 10 A gG for the signaling circuit conforming to IEC 60947-5-1.
63 A gG at <= 690 V coordination type 1 for power circuit.
40 A gG at <= 690 V coordination type 2 for the power circuit.
average impedance 2 mOhm with 40 A and 50 Hz for a power circuit.
power dissipation per pole 3.2 W AC-1.
1.25 W AC-3.
1.25 W AC-3e.
[Ui] rated insulation voltage Power circuit: 690 V, conforming to IEC 60947-4-1.
Signaling circuit: 690 V, conforming to IEC 60947-1.
overvoltage category III
pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV, conforming to IEC 60947.
safety reliability level B10d = 1369863 cycles of contactor with a nominal load conforming to EN/ISO 13849-1.
B10d = 20000000 cycles of contactor with mechanical load conforming to EN/ISO 13849-1.
mechanical durability 15 Mcycles.
electrical durability 2 Mcycles 21 A AC-3 at Ue <= 440 V.
0.9 Mcycles 40 A AC-1 at Ue <= 440 V.
2 Mcycles 21 A AC-3e at Ue <= 440 V.
control circuit type AC/DC at 50/60 Hz AC/DC electronic.
coil technology Built-in bidirectional peak limiting.
control circuit voltage limits <= 0.1 Uc (-40…70 °C): drop-out AC/DC.
0.85…1.1 Uc (-40…60 °C): operational AC.
0.8…1.1 Uc (-40…60 °C): operational DC.
1…1.1 Uc (60…70 °C): operational AC/DC.
inrush power in VA 15 VA, 50/60 Hz (at 20 °C).
inrush power in W 14 W (at 20 °C).
hold-in power consumption in VA 0.9 VA 50/60 Hz (at 20 °C).
hold-in power consumption in W 0.6 W at 20 °C
heat dissipation 0.6 W at 50/60 Hz.
operating time 45–55 ms. closing.
20…90 ms opening.
maximum operating rate 3600 cyc/h, 60 °C.
connections – terminals Control circuit: screw clamp terminals 1 1/4 mm²; cable stiffness: flexible without cable end.
Control circuit: screw clamp terminals 2 1/4 mm²; cable stiffness: flexible without cable end.
Control circuit: screw clamp terminals 1 1/4 mm²; cable stiffness: flexible with the cable end.
Control circuit: screw clamp terminals 2 1…2.5 mm²; cable stiffness: flexible with cable end.
Control circuit: screw clamp terminals 1 1/4 mm²; cable stiffness: solid.
Control circuit: screw clamp terminals 2 1/4 mm²; cable stiffness: solid.
Power circuit: screw clamp terminals 12.5…10 mm²; cable stiffness: flexible without cable end.
Power circuit: screw clamp terminals 2 2.5…10 mm²; cable stiffness: flexible without cable end.
Power circuit: screw clamp terminals 1 1…10 mm²; cable stiffness: flexible with cable end.
Power circuit: screw clamp terminals 2 1.5…6 mm²; cable stiffness: flexible with cable end.
Power circuit: screw clamp terminals 1 1.5…10 mm²; cable stiffness: solid.
Power circuit: screw clamp terminals 2 2.5…10 mm²; cable stiffness: solid.
tightening torque Control circuit: 1.7 N.m. on screw clamp terminals with a screwdriver flat Ø 6 mm.
Control circuit: 1.7 N.m. on screw clamp terminals with screwdriver Philips No. 2.
Power circuit: 2.5 N.m. on screw clamp terminals, with screwdriver flat Ø 6 mm.
Power circuit: 2.5 N.m. on screw clamp terminals with screwdriver Philips No. 2.
Power circuit: 2.5 N.m. on screw clamp terminals with screwdriver pozidriv No. 2 M4.
Control circuit: 1.7 N.m. on screw clamp terminals, with screwdriver pozidriv No. 2 M3.5.
auxiliary contact composition 1 NO + 1 NC.
auxiliary contacts type Type mechanically linked: 1 NO + 1 NC, conforming to IEC 60947-5-1.
type mirror contact 1 NC, conforming to IEC 60947-4-1.
signalling circuit frequency 25…400 Hz.
minimum switching voltage 17 V for the signaling circuit.
minimum switching current 5 mA for the signaling circuit.
insulation resistance > 10 MOhm for the signaling circuit.
non-overlap time 1.5 ms on de-energization between NC and NO contact.
1.5 ms on energization between NC and NO contact.
mounting support Plate.
Rail.
Environment
standards EN/IEC 60947-4-1.
EN/IEC 60947-5-1.
UL 60947-4-1.
CSA C22.2 No. 60947-4-1.
IEC 60335-1.
product certifications CCC
CSA
EAC
UL
KC
DNV-GL
LROS (Lloyds Register of Shipping).
UKCA
IP degree of protection IP20 front face conforms to IEC 60529.
climatic withstand Conforming to IACS E10 exposure to damp heat.
conforming to IEC 60947-1 Annex Q. category D exposure to damp heat.
permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating.
operating altitude 0…3000 m
fire resistance 850 °C, conforming to IEC 60695-2-1.
flame retardance V1 conforms to UL 94.
mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz).
Vibrations contactor closed (4 Gn, 5…300. Hz)
Shocks contactor closed (15 Gn for 11 ms).
Shocks contactor open (8 Gn for 11 ms).
height 85 mm.
width 45 mm.
depth 92 mm.
net weight 0.433 kg.
Packing Units
Unit Type of Package 1 PCE.
Number of Units in Package 1 1
Package 1 Height 5.5 cm.
Package 1 Width 9.5 cm.
Package 1 Length 12.0 cm.
Package 1 Weight 460.0 g.
Unit Type of Package 2 S02.
Number of Units in Package 2 15
Package 2 Height 15.0 cm.
Package 2 Width 30.0 cm.
Package 2 Length 40.0 cm.
Package 2 Weight 7.204 kg.