Main
range TeSys.
TeSys Deca.
range of product TeSys D.
TeSys Deca.
product or component type Contactor.
device short name LC1D.
contactor application Resistive load.
Motor control.
utilisation category AC-3.
AC-1.
AC-3e.
poles description 3P.
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz.
[Ie] rated operational current 60 A (at <60 °C) at <= 440 V AC-1 for power circuit..
40 A (at <60 °C) at <= 440 V AC-3 for power circuit.
40 A (at <60 °C) at <= 440 V AC-3e for power. circuit.
[Uc] control circuit voltage 24…60 V AC 50/60 Hz.
24…60 V DC.

.

Complementary
motor power kW 11 kW at 220…230 V AC 50 Hz (AC-3).
18.5 kW at 380…400 V AC 50 Hz (AC-3).
22 kW at 415 V AC 50 Hz (AC-3).
22 kW at 440 V AC 50 Hz (AC-3).
22 kW at 500 V AC 50 Hz (AC-3).
30 kW at 660…690 V AC 50 Hz (AC-3).
11 kW at 220–230 V AC, 50 Hz (AC-3e).
18.5 kW at 380…400 V AC 50 Hz (AC-3e).
22 kW at 415 V AC 50 Hz (AC-3e).
22 kW at 440 V AC 50 Hz (AC-3e).
22 kW at 500 V AC 50 Hz (AC-3e).
30 kW at 660…690 V AC 50 Hz (AC-3e).
motor power hp 3 hp at 115 V AC 60 Hz for 1 phase motors.
5 hp at 230/240 V AC 60 Hz for 1 phase motors.
10 hp at 200/208 V AC 60 Hz for 3 phases motors.
10 hp at 230/240 V AC 60 Hz for 3-phase motors.
30 hp at 460/480 V AC 60 Hz for 3-phase motors.
30 hp at 575/600 V AC 60 Hz for 3-phase motors.
compatibility code LC1D.
pole contact composition 3 NO.
protective cover With.
[Ith] conventional free air thermal current 60 A (at 60 °C) for the power circuit.
10 A (at 60 °C) for the signaling circuit.
Irms rated making capacity 800 A at 440 V for a power circuit conforming to IEC 60947.
140 A AC for signalling circuits conforming to IEC 60947-5-1.
250 A DC for the signaling circuit conforming to IEC 60947-5-1.
rated breaking capacity 800 A at 440 V for a power circuit conforming to IEC 60947.
[Icw] rated short-time withstand current 72 A, 40 °C, 10 min for the power circuit.
165 A, 40 °C, 1 min for the power circuit.
320 A, 40 °C, 10 s for the power circuit.
720 A, 40 °C, 1 s for the power circuit.
100 A – 1 s for the signaling circuit.
120 A to 500 ms for the signaling circuit.
140 A to 100 ms for the signaling circuit.
associated fuse rating 80 A gG at <= 690 V coordination type 1 for the power circuit.
80 A gG at <= 690 V coordination type 2 for the power circuit.
10 A gG for the signaling circuit conforming to IEC 60947-5-1.
average impedance 1.5 mOhm (60 A, 50 Hz) for a power circuit.
power dissipation per pole 5.4 W AC-1.
2.4 W AC-3.
2.4 W AC-3e.
[Ui] rated insulation voltage Power circuit: 690 V, conforming to IEC 60947-4-1.
Signaling circuit: 690 V, conforming to IEC 60947-1.
overvoltage category III.
pollution degree 3.
[Uimp] rated impulse withstand voltage 6 kV, conforming to IEC 60947.
safety reliability level B10d = 1369863 cycles of contactor with a nominal load conforming to EN/ISO 13849-1.
B10d = 20000000 cycles of contactor with mechanical load conforming to EN/ISO 13849-1.
mechanical durability 6 Mcycles.
control circuit type AC/DC at 50/60 Hz AC/DC electronic.
coil technology Built-in bidirectional peak limiting.
control circuit voltage limits <= 0.1 Uc (-40…70 °C): drop-out AC/DC.
0.85…1.1 Uc (-40…60 °C): operational AC.
0.8…1.1 Uc (-40…60 °C): operational DC.
1…1.1 Uc (60…70 °C): operational AC/DC.
operating time 55–65 ms. closing.
20…120 ms opening (date code >= 17221).
20…80 ms opening (date code >= 18011).
maximum operating rate 3600 cyc/h, 60 °C.
tightening torque Control circuit: 1.7 N.m. on screw clamp terminals with a screwdriver flat Ø 6 mm.
Control circuit: 1.7 N.m. on screw clamp terminals with screwdriver Philips No. 2.
Power circuit: 8 N.m. on EverLink BTR screw. connectors; cable 25 35 mm² hexagonal screw head, 4 mm.
Power circuit: 5 N.m. on EverLink BTR screw connectors, cable 1 25 mm² hexagonal screw head, 4 mm.
Power circuit: 2.5 N.m. on lug-ring terminals, with screwdriver pozidriv No. 2 M4.
Control circuit: 1.7 N.m. on lugs-ring terminals, with screwdriver pozidriv No. 2 M3.5.
auxiliary contact composition 1 NO + 1 NC.
auxiliary contacts type Type mechanically linked: 1 NO + 1 NC, conforming to IEC 60947-5-1.
type mirror contact 1 NC, conforming to IEC 60947-4-1.
signalling circuit frequency 25…400 Hz.
minimum switching voltage 17 V for the signaling circuit.
minimum switching current 5 mA for the signaling circuit.
insulation resistance > 10 MOhm for the signaling circuit.
non-overlap time 1.5 ms on de-energization between NC and NO contact.
1.5 ms on energization between NC and NO contact.
mounting support Plate.
Rail.
Environment
IP degree of protection IP20 front face conforms to IEC 60529.
climatic withstand Conforming to IACS E10.
conforming to IEC 60947-1 Annex Q category D.
operating altitude 0…3000 m.
fire resistance 850 °C, conforming to IEC 60695-2-1.
flame retardance V1 conforms to UL 94.
height 122 mm.
width 55 mm.
depth 120 mm.
net weight 0.992 kg.
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.2 cm.
Package 1 Width 13.7 cm.
Package 1 Length 15.2 cm.
Package 1 Weight 1.05 kg.
Unit Type of Package 2 S02.
Number of Units in Package 2 9
Package 2 Height 15 cm.
Package 2 Width 30 cm.
Package 2 Length 40 cm.