Description
range | PowerLogic. |
---|---|
product name | PowerLogic PM5000. |
device short name | PM5310. |
product or component type | Power meter. |
power quality analysis | Up to the 31st harmonic. |
---|---|
device application | Multi-tariff. Power monitoring. |
type of measurement | Current. Voltage. Frequency. Power factor. Energy. Active and reactive power. |
supply voltage | 100…415 V AC 45…65 Hz. 125…250 V DC. |
network frequency | 50 Hz 60 Hz |
[In] rated current | 1 A 5 A |
type of network | 1P + N 3P 3P + N |
maximum power consumption in VA | 10 VA at 415 V |
ride-through time | 80 ms 120 V AC is typical. 100 ms 230 V AC typical. 100 ms, 415 V AC is typical. |
display type | Backlit LCD. |
display resolution | 128 x 128 pixels. |
sampling rate | 64 samples/cycle. |
measurement current | 10…9000 mA. |
analogue input type | Voltage (impedance: 5 MOhm). Current (impedance 0.3 mOhm). |
measurement voltage | 35…690 V AC, 45…65 Hz between phases. 20…400 V AC, 45…65 Hz between phase and neutral. |
frequency measurement range | 45…65 Hz. |
number of inputs | 2 digital |
measurement accuracy | Active energy +/- 0.5%. Reactive energy +/- 2%. Active power +/- 0.5%. Apparent power +/- 0.5%. Frequency +/- 0.05%. Power factor +/- 0.005. Current +/- 0.5%. Voltage +/- 0.5%. |
accuracy class | Class 0.5S active energy conforms to IEC 62053-22. |
number of outputs | 2 digital. |
information displayed | Tariff (4) |
communication port protocol | Modbus RTU and ASCII at 9.6, 19.2, and 38.4 kbauds, even/odd or none—2 wires, insulation 2500 V. JBUS. |
communication port support | RS485 |
data recording | Event logs Min/max of instantaneous. values. Alarm logs. Data logs. Time stamping. Maintenance logs. |
memory capacity | 256 kB |
connections—terminals | Voltage circuit: screw terminal block 4. Control circuit: screw terminal block 2. Current transformer: screw terminal block 6. Input/output circuit: screw terminal block 6. Relay output: screw terminal block 4. Ethernet network: RJ45 connector. |
mounting mode | Flush-mounted. |
mounting support | Framework. |
standards | EN 50470-3. IEC 62053-24. IEC 60529. EN 50470-1. UL 61010-1. IEC 62053-22. IEC 61557-12. |
product certifications | CE conforming to IEC 61010-1. CULus conforms to UL 61010-1. |
width | 96 mm. |
depth | 72 mm. |
height | 96 mm |
net weight | 430 g |
electromagnetic compatibility | Limits for harmonic current emissions in class A conforming to IEC 61000-3-2. Electrostatic discharge level 4 conforms to IEC 61000-4-2. Conducted RF disturbances at level 3, conforming to IEC 61000-4-6. Magnetic field at power frequency level 4 conforms to IEC 61000-4-8. Conducted and radiated emissions in class B, conforming to EN 55022. |
---|---|
IP degree of protection | IP52 front: conforming to IEC 60529. IP30 body: conforming to IEC 60529. |
relative humidity | 5…95 % at 50 °C |
pollution degree | 2 |
ambient air temperature for operation | -25…70 °C |
ambient air temperature for storage | -40…85 °C |
operating altitude | 2000 m |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Weight | 492.0 g |
Package 1 Height | 11 cm |
Package 1 width | 12.6 cm |
Package 1 Length | 12.6 cm |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 12 |
Package 2 Weight | 6.4 kg |
Package 2 Height | 30 cm |
Package 2 width | 30 cm |
Package 2 Length | 40 cm |
Unit Type of Package 3 | P12 |
Number of Units in Package 3 | 288 |
Package 3 Weight | 156.0 kg |
Package 3 Height | 105 cm |
Package 3 width | 80 cm |
Package 3 Length | 120 cm |