METSEPM5310 – power meter PowerLogic PM5310
Original price was: $464.00.$357.00Current price is: $357.00.
Schneider Electric’s METSEPM5310 is a versatile power meter in the PowerLogic PM5000 series, designed for advanced energy management.
1 in stock
Free shipping on orders over $5000!
- Satisfaction Guaranteed
- No Hassle Refunds
- Secure Payments
Description
range | PowerLogic. |
---|---|
product name | PowerLogic PM5000. |
device short name | PM5310. |
product or component type | Power meter. |
power quality analysis | Up to the 31st harmonic. |
---|---|
device application | Multi-tariff. Power monitoring. |
type of measurement | Current. Voltage. Frequency. Power factor. Energy. Active and reactive power. |
supply voltage | 100…415 V AC 45…65 Hz. 125…250 V DC. |
network frequency | 50 Hz 60 Hz |
[In] rated current | 1 A 5 A |
type of network | 1P + N 3P 3P + N |
maximum power consumption in VA | 10 VA at 415 V |
ride-through time | 80 ms 120 V AC is typical. 100 ms 230 V AC typical. 100 ms, 415 V AC is typical. |
display type | Backlit LCD. |
display resolution | 128 x 128 pixels. |
sampling rate | 64 samples/cycle. |
measurement current | 10…9000 mA. |
analogue input type | Voltage (impedance: 5 MOhm). Current (impedance 0.3 mOhm). |
measurement voltage | 35…690 V AC, 45…65 Hz between phases. 20…400 V AC, 45…65 Hz between phase and neutral. |
frequency measurement range | 45…65 Hz. |
number of inputs | 2 digital |
measurement accuracy | Active energy +/- 0.5%. Reactive energy +/- 2%. Active power +/- 0.5%. Apparent power +/- 0.5%. Frequency +/- 0.05%. Power factor +/- 0.005. Current +/- 0.5%. Voltage +/- 0.5%. |
accuracy class | Class 0.5S active energy conforms to IEC 62053-22. |
number of outputs | 2 digital. |
information displayed | Tariff (4) |
communication port protocol | Modbus RTU and ASCII at 9.6, 19.2, and 38.4 kbauds, even/odd or none—2 wires, insulation 2500 V. JBUS. |
communication port support | RS485 |
data recording | Event logs Min/max of instantaneous. values. Alarm logs. Data logs. Time stamping. Maintenance logs. |
memory capacity | 256 kB |
connections—terminals | Voltage circuit: screw terminal block 4. Control circuit: screw terminal block 2. Current transformer: screw terminal block 6. Input/output circuit: screw terminal block 6. Relay output: screw terminal block 4. Ethernet network: RJ45 connector. |
mounting mode | Flush-mounted. |
mounting support | Framework. |
standards | EN 50470-3. IEC 62053-24. IEC 60529. EN 50470-1. UL 61010-1. IEC 62053-22. IEC 61557-12. |
product certifications | CE conforming to IEC 61010-1. CULus conforms to UL 61010-1. |
width | 96 mm. |
depth | 72 mm. |
height | 96 mm |
net weight | 430 g |
electromagnetic compatibility | Limits for harmonic current emissions in class A conforming to IEC 61000-3-2. Electrostatic discharge level 4 conforms to IEC 61000-4-2. Conducted RF disturbances at level 3, conforming to IEC 61000-4-6. Magnetic field at power frequency level 4 conforms to IEC 61000-4-8. Conducted and radiated emissions in class B, conforming to EN 55022. |
---|---|
IP degree of protection | IP52 front: conforming to IEC 60529. IP30 body: conforming to IEC 60529. |
relative humidity | 5…95 % at 50 °C |
pollution degree | 2 |
ambient air temperature for operation | -25…70 °C |
ambient air temperature for storage | -40…85 °C |
operating altitude | 2000 m |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Weight | 492.0 g |
Package 1 Height | 11 cm |
Package 1 width | 12.6 cm |
Package 1 Length | 12.6 cm |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 12 |
Package 2 Weight | 6.4 kg |
Package 2 Height | 30 cm |
Package 2 width | 30 cm |
Package 2 Length | 40 cm |
Unit Type of Package 3 | P12 |
Number of Units in Package 3 | 288 |
Package 3 Weight | 156.0 kg |
Package 3 Height | 105 cm |
Package 3 width | 80 cm |
Package 3 Length | 120 cm |
The METSEPM5310 is a sophisticated power meter from Schneider Electric’s PowerLogic PM5000 series. Designed for advanced energy management and monitoring, this device is ideal for industrial, commercial, and utility applications. The PM5310 provides precise measurements of a wide range of electrical parameters, helping users optimize energy usage, reduce costs, and improve the reliability of their power systems.
Key Features and Specifications
Comprehensive Monitoring:
The METSEPM5310 measures various electrical parameters, including voltage, current, power, energy, frequency, and power factor. This extensive monitoring capability provides a detailed understanding of the electrical system’s performance.
High Accuracy:
The PM5310 boasts high accuracy, with a class 0.5S accuracy for active energy in compliance with IEC 62053-22 standards. This ensures reliable and precise data, essential for energy management and billing.
Advanced Data Logging:
This power meter can log and store historical data, enabling detailed analysis of energy usage patterns. Users can access this data to identify trends, detect anomalies, and implement energy-saving strategies.
Real-Time Data Display:
The device features a bright, backlit LCD display that shows real-time electrical parameters and diagnostic information. The user-friendly interface allows for easy navigation through various menus and settings.
Communication Capabilities:
The PM5310 supports multiple communication protocols, including Modbus RTU and Modbus TCP, facilitating seamless integration with energy management systems and building management systems for remote monitoring and control.
Configurable Alarms and Event Logging:
The power meter includes configurable alarms that can be set for various parameters. When thresholds are exceeded, alarms are triggered, helping users address issues promptly. Event logging provides a record of significant occurrences, aiding in troubleshooting and maintenance.
Power Quality Analysis:
The METSEPM5310 is capable of basic power quality analysis, including harmonic distortion measurement up to the 15th harmonic. This feature is crucial for maintaining the quality and stability of the power supply.
Robust Design:
Built to withstand harsh industrial environments, the PM5310 operates reliably under wide temperature ranges and is resistant to electromagnetic interference (EMI). This robustness ensures long-term durability and consistent performance.
Flexible Installation:
The compact design of the METSEPM5310 allows for easy installation in various settings. It can be mounted on DIN rails or panels, fitting seamlessly into existing electrical distribution systems.
Applications
Industrial Facilities:
In manufacturing plants and industrial settings, the METSEPM5310 monitors critical electrical parameters to optimize energy consumption, enhance efficiency, and reduce operational costs. It helps identify energy-intensive equipment and areas for improvement.
Commercial Buildings:
Facility managers use the PM5310 to monitor and manage energy usage in commercial buildings, aiming to lower utility bills and improve energy efficiency. It supports initiatives for demand response and sustainability.
Utilities and energy providers:
The PM5310 is used by utilities and energy providers for accurate metering and billing. Its high accuracy and data-logging capabilities ensure reliable measurement and customer satisfaction.
Renewable Energy Systems:
In renewable energy installations, such as solar and wind power systems, the METSEPM5310 monitors energy generation and consumption, ensuring optimal performance and efficient energy management.
Installation and Configuration
Physical Installation:
The METSEPM5310 can be easily installed on DIN rails or panels. Its compact size allows it to fit into existing electrical distribution panels without significant modifications.
Wiring and Connections:
The power meter supports both direct and current transformer (CT) connections. Clear labeling and detailed documentation guide users through the wiring process, ensuring accurate connections and measurements.
Software Configuration:
Schneider Electric provides user-friendly software tools for configuring the PM5310. The configuration process involves setting up communication parameters, measurement settings, and alarm thresholds. The software also allows for firmware updates to keep the device up-to-date with the latest features and improvements.
Integration with Management Systems:
The METSEPM5310 communicates with energy management systems (EMS) and building management systems (BMS) via Modbus RTU and Modbus TCP. This integration enables centralized monitoring, data analysis, and control, enhancing overall energy management capabilities.
Benefits
Energy Efficiency:
By providing detailed insights into energy usage, the METSEPM5310 helps users identify inefficiencies and implement corrective actions, leading to reduced energy consumption and lower utility bills.
Cost Savings:
Accurate monitoring and management of energy usage result in significant cost savings. Users can optimize their energy consumption, avoid peak demand charges, and improve overall operational efficiency.
Improved Reliability:
The meter’s advanced diagnostic features and alarm capabilities help in early detection of issues, preventing potential failures, and ensuring the reliability of electrical systems.
Sustainability:
The METSEPM5310 supports sustainability initiatives by enabling users to monitor and reduce their carbon footprint. It helps in achieving energy efficiency targets and compliance with environmental regulations.
Maintenance and Troubleshooting
Regular Inspection:
Periodic inspection of the power meter and its connections ensures reliable operation. Checking for loose connections, signs of wear, or damage helps prevent potential issues.
Firmware Updates:
Schneider Electric may release firmware updates to enhance the functionality and performance of the PM5310. Keeping the firmware up-to-date ensures the latest features and improvements are available.
Diagnostic Tools:
Utilizing the meter’s built-in diagnostic features and software tools helps in identifying and resolving issues quickly. Detailed diagnostic information aids in pinpointing the root cause of problems, reducing downtime.
Technical Support:
Schneider Electric provides comprehensive technical support for the METSEPM5310. Access to expert assistance and detailed documentation ensures users can resolve any issues effectively.
Conclusion
The METSEPM5310 power meter from Schneider Electric’s PowerLogic PM5000 series is a versatile and reliable tool for advanced energy management and monitoring. Its high accuracy, robust design, and advanced features make it an ideal choice for industrial, commercial, and utility applications. By providing detailed insights into energy usage and enabling effective management, the METSEPM5310 helps users achieve energy efficiency, cost savings, and improved reliability.