METSEPM5560 – power meter PowerLogic PM5560
Original price was: $1,065.00.$820.00Current price is: $820.00.
Schneider Electric’s METSEPM5560 PowerLogic PM5560 power meter offers comprehensive energy measurement and monitoring capabilities.
20 in stock
Free shipping on orders over $5000!
- Satisfaction Guaranteed
- No Hassle Refunds
- Secure Payments
Description
| range | PowerLogic. |
|---|---|
| product name | PowerLogic PM5000. |
| device’s short name | PM5560. |
| product or component type | Power meter |
| power quality analysis | Up to the 63rd harmonic. |
|---|---|
| metering type | Measured neutral current. Calculated ground current. |
| device application | Gateway. WAGES metering. Power monitoring. Multi-tariff |
| type of measurement | Current. Voltage. Frequency. Power factor. Energy. Active and reactive power. |
| supply voltage | 125–250 V DC. 100…480 V AC 45…65 Hz. |
| network frequency | 60 Hz. 50 Hz. |
| [In] rated current | 1 A. 5 A. |
| type of network | 3P + N. 3P. 1P + N. |
| maximum power consumption in VA | 10 VA at 480 V. |
| ride-through time | 35 ms 120 V AC is typical. 129 ms 230 V AC, typical. |
| display type | Backlit LCD. |
| display resolution | 128 x 128 pixels. |
| sampling rate | 128 samples/cycle. |
| measurement current | 5…10000 mA |
| analogue input type | Voltage (impedance: 5 MOhm). Current (impedance: 0.3 mOhm). |
| measurement voltage | 20…400 V AC 45…65 Hz between phase and neutral. 20…690 V AC 45…65 Hz between phases. |
| frequency measurement range | 45…65 Hz. |
| number of inputs | 4 digital |
| measurement accuracy | Apparent power +/- 0.5 %. Frequency +/- 0.05 %. Active energy +/- 0.2 %. Reactive energy +/- 1 %. Active power +/- 0.2 %. Voltage +/- 0.1 %. Power factor +/- 0.005. Current +/- 0.15 °C. |
| accuracy class | Class 0.2S active energy conforming to IEC 62053-22. |
| number of outputs | 2 digital. |
| information displayed | Tariff (8). |
| communication port protocol | Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds, even/odd or none—2 wires, insulation 2500 V. JBUS. Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V Ethernet Modbus TCP/IP daisy chain. BACnet IP. |
| communication port support | RS485 Ethernet. |
| communication gateway | Ethernet/serial. |
| data recording | Event logs. Maintenance logs. Min/max of instantaneous values. Data logs. Alarm logs. Time stamping. |
| memory capacity | 1.1 MB. |
| web services | Alarm notification by e-mail. Diagnostic via predefined web pages. Web server. Real-time viewing of data. |
| Ethernet service | SNTP client. SNMP-Traps. |
| connections—terminals | Voltage circuit: screw terminal block 4. Control circuit: screw terminal block 2. Current transformer: screw terminal block 6. RS485 link: screw terminal block 4. Digital input: screw terminal block 8. Digital output: screw terminal block 4. Ethernet network: RJ45 connector 2. |
| mounting mode | Flush-mounted. |
| mounting support | Framework. |
| standards | EN 50470-3. IEC 61557-12. IEC 62053-22. IEC 62053-24. IEC 60529. EN 50470-1. UL 61010-1. ANSI C12.20. |
| product certifications | CE conforming to IEC 61010-1. CULus conforming to UL 61010-1. BTL |
| width | 96 mm. |
| depth | 72 mm. |
| height | 96 mm. |
| net weight | 450 g. |
| electromagnetic compatibility | Limits for harmonic current emissions class A, conforming to IEC 61000-3-2. Conducted RF disturbances level 3, conforming to IEC 61000-4-6. Magnetic field at power frequency level 4 conforming to IEC 61000-4-8. Conducted and radiated emissions class B conforming to EN 55022. Limitation of voltage changes, voltage fluctuations. and flicker in low-voltage conforming to IEC 61000-3-3. Electrostatic discharge, test level: 8 kV, level 4, conforming to IEC 61000-4-2. Radiated radio-frequency electromagnetic field. immunity test conforming to IEC 61000-4-3. Electrical fast transient/burst immunity test level 4, conforming to IEC 61000-4-4. Surge immunity test level 4 conforming to IEC 61000-4-5. Voltage dips and interruptions immunity test conforming to IEC 61000-4-11. |
|---|---|
| IP degree of protection | IP52 front: conforming to IEC 60529. IP30 body: conforming to IEC 60529. |
| relative humidity | 5… 95%% at 50 °C. |
| pollution degree | 2 |
| ambient air temperature for operation | -25…70 °C. |
| ambient air temperature for storage | -40…85 °C. |
| operating altitude | 3000 m |
| Unit Type of Package 1 | PCE. |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1: Weight | 661 g. |
| Package 1: Height | 12.91 cm. |
| Package: 1 width | 13.271 cm. |
| Package 1 Length | 13.277 cm. |
| Sustainable offer status | Green Premium product. |
|---|---|
| REACh Regulation | REACh Declaration. |
| EU RoHS Directive |
Compliant
EU RoHS Declaration. |
| Mercury free | Yes |
| RoHS exemptioninformation | Yes |
| China’s RoHS Regulation | China RoHS declaration. |
| Circularity Profile | End-of-life information. |
| WEEE | The product must be disposed of on European Union markets following specific waste collection and never end up in rubbish bins. |
| California proposition 65 | Warning: Cancer and Reproductive Harm. |