SCHNEIDER ELECTRIC CM4250
Original price was: $6,786.00.$5,220.00Current price is: $5,220.00.
Free shipping on orders over $5000!
- Satisfaction Guaranteed
- No Hassle Refunds
- Secure Payments
Description
Model:CM4250
Manufacturer :Schneider Electric
Square D
PowerLogic Circuit Monitor
100V-277V, 50VA, 50/60HZ
Schneider Electric Square D Powerlogic CM4250 Circuit Monitor
125V-250V 30W
CM4250
KYZ: 240V/300V 96mA MAX
CVM42
690V L-L/400V L-N MAX
5A NOM/10A MAX
Let us know your offer if the mentioned price is not good for you.
range |
PowerLogic.
|
|
---|---|---|
product name |
PowerLogic BCPM.
|
|
product or component type |
Multi-circuit energy meter.
|
|
device’s short name |
BCPMA.
|
|
Model type |
Advanced.
|
|
power monitoring |
Basic instrumentation.
|
|
energy management |
Sub-billing and cost allocation.
|
|
device application |
Sub billing.
|
|
power quality analysis |
voltage sag and swell detection.
|
|
type of measurement |
Voltage.
Current. Frequency. Active power. Power factor. Active energy. |
|
[Us] rated supply voltage |
90…277 V AC 50/60 Hz +/- 1%.
|
|
network frequency |
60 Hz.
50 Hz. |
current transformer input |
Solid-core CT 100 A42x.
|
|
---|---|---|
update time |
1.8 s
|
|
measurement voltage |
90…277 V phase to neutral.
150…480 V, phase to phase. |
|
measurement accuracy |
Branch current: 2%, 0.25…2 A.
Branch current: 1%, 2… 100 A. Mains current: 3%, 1%, 100%. Mains current 3 % 2…100 %. Voltage: 1 % 90…277 V |
|
sampling rate |
256 samples/cycle.
|
|
connection pitch |
19 mm
|
|
provided equipment |
42 x current transformer.
2 x cables. |
|
communication port protocol |
Modbus RTU.
|
|
communication port support |
RS485.
|
|
communication of data |
Low-current alarm.
High-current alarm. Low-current alarm. Under voltage alarm. High-current alarm. Over-voltage alarm. |
mounting mode |
Panel-mounted.
|
|
---|---|---|
mounting support |
Enclosure.
Panel. |
|
relative humidity |
0…95% at 0…60 °C.
|
|
ambient air temperature for storage |
-40…70 °C.
|
|
operating altitude |
3000 m
|
|
standards |
IEC 61036.
ANSI C12.1. UL 508. EN 61010. |
|
product certifications |
UL.
|
|
width |
288 mm.
|
|
height |
146 mm.
|
|
net weight |
1.5 kg.
|
Package 1: Weight |
2500.000 g.
|
|
---|---|---|
Package 1: Height |
159.000 mm.
|
|
Package: 1 width |
248.000 mm.
|
|
Package 1 Length |
794.000 mm.
|
REACh Regulation |
REACh Declaration.
|
|
---|---|---|
EU RoHS Directive |
Compliant
EU RoHS Declaration. |
|
Mercury free |
Yes
|
|
RoHS exemption information |
Yes
|
|
China’s RoHS Regulation |
China RoHS declaration.
|
|
WEEE |
The product must be disposed of on European Union markets following specific waste collection procedures and never end up in rubbish bins.
|
Warranty |
18 months
|
---|
The Schneider Electric CM4250 digital meter is an advanced and versatile tool designed for energy management, power quality monitoring, and data logging in industrial and commercial environments. This meter offers a comprehensive range of measurement capabilities, high accuracy, and robust communication features, making it an essential component for optimizing energy usage and ensuring the reliability of electrical systems.
Measurement Capabilities
The CM4250 provides extensive measurement capabilities, covering a wide range of electrical parameters:
- Voltage Measurement:
- Measures phase-to-neutral and phase-to-phase voltages with an accuracy of ±0.2% of reading.
- Voltage range: 0 to 600V (phase-to-phase) and 0 to 347V (phase-to-neutral).
- Current Measurement:
- Measures current in each phase with an accuracy of ±0.2% of reading.
- Current range: 0.1A to 10A (direct input), with the capability to measure higher ranges using external current transformers (CTs).
- Power Measurement:
- Measures active, reactive, and apparent power with an accuracy of ±0.5% of reading.
- Provides real-time power measurements to monitor and manage electrical loads effectively.
- Energy Measurement:
- Measures energy consumption, including active and reactive energy, with an accuracy of ±0.5% of reading.
- It helps in tracking energy usage over time for cost allocation and efficiency improvement.
- Frequency Measurement:
- Monitors the frequency of the electrical supply with an accuracy of ±0.01 Hz.
- Frequency range: 45 to 65 Hz.
- Harmonic Analysis:
- Measures total harmonic distortion (THD) for voltage and current.
- Provides analysis of individual harmonics up to the 50th order, helping to identify and address power quality issues.
Display and Interface
The CM4250 features a user-friendly display and interface designed for ease of use and clear visibility.
- LCD/LED Display:
- Large, backlit display for easy reading of multiple parameters simultaneously.
- A high-resolution display ensures precise reading of values.
- User Interface:
- Equipped with buttons or a touch screen for navigation through menus and settings.
- Intuitive menu structure for quick access to measurement data and configuration options.
Contact