59658 – 2 Ethernet ports interface 10/100BASE-TX
$617.00 Original price was: $617.00.$575.00Current price is: $575.00.
10 in stock
Free shipping on orders over $5000!
- Satisfaction Guaranteed
- No Hassle Refunds
- Secure Payments
Category: Relays
Description
Range of product | Sepam series 40. Sepam series 80 NPP. Sepam series 60. Sepam series 80. |
---|---|
Device short name | ACE850TP. |
communication port protocol | ARP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX. FTP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX. HTTP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX. IEC 61850 network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX. Modbus RTU network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX. Modbus TCP/IP network: S-LAN and E-LAN.. interface: 2 Ethernet ports 10/100BASE-TX. RSTP 801.1d 2004 network: S-LAN and E-LAN. interface: 2 Ethernet ports 10/100BASE-TX.. SNMP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX. SNTP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX. |
---|---|
local signalling | Green LED1 for energized (front face). Green LED2 for communication status ok (front face). Green LED3 off for port 2 Ethernet 10 Mbit/s (front face). Green LED3 on for port 2 Ethernet 100 Mbit/s (front face). Green LED4 flashing. for port 2 Ethernet sending data and receiving data (front face). Green LED5 off for port 1 Ethernet 10 Mbit/s (front face). Green LED5 on for port 1 Ethernet 100 Mbit/s (front face). Green LED6 flashing for port 1 Ethernet sending data and receiving data (front face). Red LED1 flashing for not set up or not base-unit connected (front face). Red LED1 off for de-energized (front face). Red LED1 remains ON for fault (front face). |
[Us] rated supply voltage | 110…240 V AC tolerance: – 20…10 %. 24…250 V DC tolerance: – 20…10 %. |
Mounting mode | Fixed. |
Mounting support | Symmetrical DIN rail. |
Height | 127 mm. |
Width | 171 mm. |
Depth | 58 mm. |
Product weight | 0.4 kg. |
mechanical robustness | Earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3. Earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3. Jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2. Shocks de-energized (level: 2) : 30 Gn/11 ms conforming to IEC 60255-21-2. Shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2. Vibrations de-energized (level: 2) : 2 Gn, 10 Hz, 150 Hz, conforming to IEC 60255-21-1. Vibrations in operation (level: 2) : 1 Gn, 10 Hz, 150 Hz, conforming to IEC 60255-21-1. Vibrations in operation (level: Fc) : 2 Hz–13.2 Hz, a = +/- 1 mm, conforming to IEC 60068-2-6. |
maximum cable distance between devices | <100 m. |
auxiliary connection terminal | Functional earth: ring lug 1 pin(s) 1 cable(s) tinned copper braid 4 mm². Protective earth: screw-type connector 1 pin(s) 1 cable(s) wire 2.5 mm² <3 m. Supply: screw-type connector 3 pin(s) 1 cable(s) wire 0.5…2.5 mm². Supply: screw-type connector 3 pin(s) 1 cable(s) wire 1.5 mm². Supply: screw-type connector 3 pin(s) 1 cable(s) wire 2.5 mm² Supply: screw-type conne.ctor 3 pin(s) 2 cable(s) wire 0.5…1 mm². Supply: screw-type connector 3 pin(s) 2 cable(s) wire 1 mm². Supply: screw-type connector 4 pin(s) 1 cable(s) wire 0.5…2.5 mm². Supply: screw-type connector 4 pin(s) 1 cable(s) wire 1.5 mm². Supply: screw-type connector 4 pin(s) 1 cable(s) wire 2.5 mm². Supply: screw-type connector 4 pin(s) 2 cable(s) wire 0.5…1 mm². Supply: screw-type connector 4 pin(s) 2 cable(s) wire 1 mm². |
wire stripping length | Supply: 8 mm. |
electromagnetic compatibility | 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC and MD, conforming to ANSI C37.90.1. 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), III, 2.5 kV MC, 1 kV MD, conforming to IEC 60255-22-1. 100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC, 1 kV MD, conforming to IEC 61000-4-12. Conducted disturbance emission: (emission tests), conforming to IEC 60255-25. Conducted disturbance emission: (emission tests), B, conforming to EN 55022. Disturbing field emission: (emission tests), conforming to IEC 60255-25. Disturbing field emission: (emission tests), A, conforming to EN 55022. Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3. Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2. Fast transient bursts: (immunity tests-conducted. disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1 Fast transient bursts: (immunity tests-conducted. disturbances), A or B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4. Fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4. Immunity to conducted RF disturbances: (immunity tests-conducted disturbances), 10 V, conforming to IEC 60255-22-6. Immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m. (continuous)-300 A/m (13 s), conforming to IEC 61000-4-8 Immunity to radiated fields: (immunity tests-radiated. disturbances), 10 V/m, 80 MHz…1 GHz, conforming to IEC 60255-22-3. Immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz…1 GHz, conforming to ANSI C37.90.2 (1995). Immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz…2 GHz, conforming to IEC 61000-4-3. Surges: (immunity tests-conduct.ed disturbances), III, 2 kV MC, 1 kV MD, conforming to IEC 61000-4-5. Voltage interruptions: (immunity tests-conducted. disturbances), 100 %, 10 ms, conforming to IEC 60255-11. |
---|---|
climatic withstand | Influence of corrosion/gaz test 4 (in operation) : 21 days, 75. % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.02 ppm NO2, 0.01 ppm Cl2 conforming to IEC 60068-2-60 Continuous exposure to damp heat (in operation): Ca: 10 days, 93% RH, 40 °C (104 °F), conforming to IEC 60068-2-3. Continuous exposure to damp heat (in storage): Ca: 56 days, 93% RH, 40 °C (104 °F), conforming to IEC 60068-2-3. Exposure to cold (in operation): Ab: -25 °C (-13 °F) conforming to IEC 60068-2-1. Exposure to cold (in storage): Ab: -25 °C (-13 °F) conforming to IEC 60068-2-1. Exposure to dry heat (in operation): Bb: 70 °C (158 °F) conforming to IEC 60068-2-2. Exposure to dry heat (in storage) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2. Influence of corrosion/gaz test 2 (in operation) : C: 21 days, 75 % RH, 25 °C (- 13 °F), 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60. Salt mist (in operation) : Kb/2 conforming to IEC 60068-2-52. Temperature variation with specified variation rate (in operation) : Nb: – 25 °C to 70 °C (- 13 °F to 158 °F) 5. °C/min (41 °F/min) conforming to IEC 60068-2-14. |
Ambient air temperature for operation | -25…70 °C. |
Unit Type of Package 1 | PCE. |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 9.800 cm. |
Package 1 Width | 16.700 cm. |
Package 1 Length | 19.800 cm. |
Package 1 Weight | 721 g |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 6 |
Package 2 Height | 30.000 cm. |
Package 2 Width | 30.000 cm. |
Package 2 Length | 40.000 cm. |
Package 2 Weight | 4.733 kg. |
Unit Type of Package 3 | P12 |
Number of Units in Package 3 | 48 |
Package 3 Height | 44.500 cm. |
Package 3 Width | 80.000 cm. |
Package 3 Length | 120.000 cm. |
Package 3 Weight | 49.784 kg. |
Related products
-
Sale!
SCHNEIDER ELECTRIC 499NEH14100
$703.80Original price was: $703.80.$633.42Current price is: $633.42. -
Sale!
DSE331 Switch Control Module
$421.00Original price was: $421.00.$324.00Current price is: $324.00. -
Sale!
59658 Ethernet Ports Interface
$624.00Original price was: $624.00.$480.00Current price is: $480.00. -
Sale!
CUTLER HAMMER MP-3000
$4,500.00Original price was: $4,500.00.$4,050.00Current price is: $4,050.00.