Sale!

TSXDSY16R5 – Discrete output module, Modicon Premium

Original price was: $1,131.00.Current price is: $870.00.

The Modicon Premium TSXDSY16R5 discrete output module provides 16 relay outputs, supporting 24-240V AC/DC and up to 5A per channel.

9 in stock

Categories: ,

Description

Main
range of product Modicon Premium Automation platform.
product or component type Discrete output module.
discrete output number 16
discrete output type Relay not protected.
discrete output voltage 12…24 V DC conforming to EN/IEC 61131-2 10…34 V.
24…240 V AC conforming to EN/IEC 61131-2 20…264. V
Complementary
[Ith] conventional free air thermal current 3 A
response time < 10 ms (deactivation).
< 8 ms (activation).
contacts type and composition 1 NO
output overvoltage protection DC inductive, by discharge diode on each. preactuator.
AC inductive, by RC circuit MOV (ZNO) on. each preactuator.
output overload protection 1 external fuse per channel or group of channel fast blow.
short-circuit protection 1 external fuse per channel or group of channel fast blow.
isalotion resistance > 10 MOhm 500 V.
power dissipation (0.25 W + 0.2 W x No of outputs at state 1).
electrical durability 1000000 cycles of DC-12, 24 W, and 24 V resistive.
1000000 cycles of DC-3, 24 W, and 24 V inductive.
2000000 cycles of DC-3, 10 W, 24 V inductive.
300000 cycles of DC-12, 40 W, 24 V resistive.
100000 cycles of AC-14, 220 VA, and 220 V inductive.
100000 cycles of AC-15, 220 VA, and 220 V inductive.
1000000 cycles AC-12 110 VA 110 V resistive
1000000 cycles of AC-12, 220 VA, and 220 V resistive.
1000000 cycles of AC-12, 50 VA, and 48 V resistive.
1000000 cycles AC-14 110 VA 220 V inductive.
1000000 cycles AC-15 110 VA 220 V inductive.
150000 cycles AC-14 110 VA 110 V inductive.
150000 cycles AC-15 110 VA 110 V inductive.
1500000 cycles AC-14, 50 VA, 110 V inductive.
1500000 cycles AC-15, 50 VA, 110 V inductive.
2000000 cycles AC-14 24 VA 48 V inductive.
2000000 cycles AC-15, 24 VA, 48 V inductive.
3000000 cycles AC-14, 50 VA, 220 V inductive.
3000000 cycles AC-15, 50 VA, 220 V inductive.
500000 cycles AC-12 110 VA 48 V resistive.
500000 cycles AC-12, 220 VA, 110 V resistive.
500000 cycles of AC-14, VA, and 24 V inductive.
500000 cycles of AC-15, VA, and 24 V inductive.
5000000 cycles AC-14 10 VA 110 V inductive.
5000000 cycles AC-14 10 VA 220 V inductive.
5000000 cycles AC-14 10 VA 48 V inductive.
5000000 cycles AC-15 10 VA 110 V inductive.
5000000 cycles AC-15 10 VA 220 V inductive.
5000000 cycles AC-15 10 VA 48 V inductive.
700000 cycles of AC-12, 50 VA, 24 V resistive.
marking CE
electrical connection Screw terminal block.
current consumption 135 mA at a 24 V DC rack.
80 mA at 5 V DC.
module format Standard
net weight 0.38 kg
Environment
dielectric strength 2000 V 50/60 Hz, 60 s.
standards 73/23/EEC.
IEC 61131-2.
UL 508.
CSA C22.2 No. 213, Class I Division 2, Group. B
92/31/EEC.
89/336/EEC.
CSA C22.2 No. 213 Class I Division 2 Group C.
CSA C22.2 No. 213: Class I, Division 2, Group A.
CSA C22.2 No. 142.
CSA C22.2 No. 213: Class I, Division 2, Group D.
93/68/EEC.
product certifications BV.
RINA.
LR..
ABS
RMRS.
GL.
DNV.
ambient air temperature for operation 0…60 °C.
ambient air temperature for storage -25…70 °C
relative humidity 10…95% without condensation for. operation.
5% without condensation for storage.
operating altitude 0…2000 m.
protective treatment TC
IP degree of protection IP20.
pollution degree 2
Packing Units
Unit Type of Package 1 PCE.
Number of Units in Package 1 1
Package 1 Weight 482.0 g.
Package 1 Height 5.5 cm.
Package 1 width 18.0 cm.
Package 1 Length 26.0 cm.
Unit Type of Package 2 S03
Number of Units in Package 2 8
Package 2 Weight 4.371 kg.
Package 2 Height 30.0 cm.
Package 2 width 30.0 cm.
Package 2 Length 40.0 cm.

The TSXDSY16R5 is a discrete output module from the Modicon Premium range, designed to meet the high demands of industrial automation and control systems. This module offers reliable performance and versatility, making it a popular choice for various applications in manufacturing, processing, and other industrial sectors. This comprehensive guide delves into the specifications, features, applications, installation process, and frequently asked questions about the TSXDSY16R5 discrete output module.

Specifications

  1. Module Type: Discrete output module
  2. Output Channels: 16
  3. Output Type: Relay
  4. Output Voltage Range: 24-240V AC/DC
  5. Output Current per Channel: Up to 5A
  6. Isolation: Optical isolation between channels and the bus
  7. Response Time: Typically within 10ms
  8. Power Dissipation: Low power consumption for efficient operation
  9. Dimensions: Standard size for Modicon Premium racks
  10. Connector Type: Removable screw terminal block for easy wiring
  11. Environmental Ratings: Suitable for industrial environments with standard operating temperature and humidity ranges
  12. Certifications: Compliant with relevant industry standards for safety and performance

Features

1. High Density and Flexibility The TSXDSY16R5 offers 16 discrete output channels in a single module, providing high-density output capabilities. This allows for more compact and efficient control system designs.

2. Wide Voltage Range With an output voltage range of 24-240V AC/DC, this module can handle a variety of industrial applications, supporting both low and high voltage control needs.

3. Robust Relay Outputs The relay outputs are designed to handle up to 5A per channel, ensuring reliable switching of loads such as motors, solenoids, and other actuators.

4. Optical Isolation The optical isolation between channels and the system bus enhances safety and reliability by protecting the control system from electrical noise and potential damage from voltage spikes.

5. Fast Response Time A response time of typically within 10ms ensures that the module can quickly react to control signals, which is crucial for time-sensitive automation tasks.

6. Easy Installation and Maintenance The removable screw terminal block simplifies wiring and maintenance, allowing for quick and easy connection of field devices.

7. Durable Construction Built to withstand industrial environments, the TSXDSY16R5 features robust construction and components that ensure long-term reliability and performance.

Applications

The TSXDSY16R5 discrete output module is ideal for a wide range of industrial applications, including:

1. Manufacturing Automation Used in assembly lines, packaging systems, and robotic control, the module facilitates precise and reliable control of various manufacturing processes.

2. Process Control In industries such as chemical processing, water treatment, and food and beverage production, the module provides reliable switching for valves, pumps, and other process control devices.

3. Building Automation The module can be used in HVAC systems, lighting control, and security systems to automate and optimize building operations.

4. Energy Management It plays a role in energy management systems by controlling relays that switch power circuits, contributing to efficient energy use and monitoring.

5. Transportation In transportation systems, the module is used to control signaling equipment, gates, and other automated components that require reliable switching capabilities.

Installation and Setup

1. Unpacking and Inspection Carefully unpack the TSXDSY16R5 module and inspect it for any damage that may have occurred during shipping. Verify that all components are present and in good condition.

2. Mounting Install the module in a suitable rack or enclosure that provides adequate protection and ventilation. Ensure that the module is securely mounted to prevent vibration and movement.

3. Wiring Connect the field devices to the module using the removable screw terminal block. Ensure that all connections are secure and properly labeled. Follow the wiring diagram provided in the user manual to avoid any incorrect connections.

4. Power Supply Connect the module to the appropriate power supply. Verify that the voltage and current ratings match the specifications of the module.

5. Configuration Configure the module settings as required for your specific application. This may involve setting parameters such as output channel assignments, voltage levels, and response times.

6. Testing Perform a thorough test of the system to ensure that all outputs are functioning correctly. Check for proper operation of connected devices and verify that the module responds accurately to control signals.