Sale!

METSEPM5563RD – power meter PowerLogic PM5563

Original price was: $1,235.00.Current price is: $950.00.

The PowerLogic PM5563RD is an advanced power meter from Schneider Electric, designed for precise measurement and monitoring of electrical systems.

1 in stock

Free shipping on orders over $5000!

  • Check Mark Satisfaction Guaranteed
  • Check Mark No Hassle Refunds
  • Check Mark Secure Payments
GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
Categories: ,

Description

Main
rangePowerLogic.
product namePowerLogic PM5000.
device’s short namePM5563.
product or component typePower meter.
Complementary
power quality analysisUp to the 63rd harmonic.
metering typeMeasured neutral current.
Calculated ground current.
device applicationGateway.
Power monitoring.
WAGES metering.
Multi-tariff
type of measurementCurrent.
Voltage.
Frequency.
Power factor.
Energy.
Active and reactive power.
supply voltage125–250 V DC.
100…480 V AC 45…65 Hz.
network frequency50 Hz.
60 Hz.
[In] rated current1 A.
5 A
type of network1P + N.
3P.
3P + N.
maximum power consumption in VA10 VA at 480 V.
ride-through time35 ms 120 V AC is typical.
129 ms 230 V AC, typical.
display typeRemote LCD display.
display resolution128 x 128 pixels.
sampling rate128 samples/cycle.
measurement current5…10000 mA.
analogue input typeVoltage (impedance: 5 MOhm).
Current (impedance: 0.3 mOhm).
measurement voltage20…400 V AC 45…65 Hz between phase and neutral.
20…690 V AC 45…65 Hz between phases.
frequency measurement range45…65 Hz.
number of inputs4 digital
measurement accuracyApparent power +/- 0.5 %.
Frequency +/- 0.05 %.
Active energy +/- 0.2 %.
Reactive energy +/- 1 %.
Active power +/- 0.2 %.
Voltage +/- 0.1 %.
Power factor +/- 0.005.
Current +/- 0.15 °C.
accuracy classClass 0.2S active energy conforming to IEC 62053-22.
number of outputs2 digital
information displayedTariff (8)
communication port protocolModbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds,. even/odd or none—2 wires, insulation 2500 V.
JBUS
Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V.
Ethernet Modbus TCP/IP daisy chain.
BACnet IP.
communication port supportRS485.
Ethernet.
communication gatewayEthernet/serial.
data recordingTime stamping.
Data logs.
Maintenance logs.
Event logs.
Alarm logs.
Min/max of instantaneous values.
memory capacity1.1 MB.
web servicesDiagnostic via predefined web pages.
Real-time viewing of data.
Web server.
Alarm notification by e-mail.
Ethernet serviceSNTP client.
SNMP-Traps.
connections—terminalsVoltage circuit: screw terminal block 4.
Control circuit: screw terminal block 2.
Current transformer: screw terminal block 6.
RS485 link: screw terminal block 4.
Digital input: screw terminal block 8.
Digital output: screw terminal block 4.
Ethernet network: RJ45 connector 2.
mounting modeClip-on
mounting supportDIN rail.
standardsEN 50470-3..
EN 50470-1.
IEC 62053-22.
IEC 60529.
UL 61010-1..
IEC 62053-24.
IEC 61557-12.
ANSI C12.20.
product certificationsCE conforming to IEC 61010-1.
CULus conforming to UL 61010-1.
BTL
width96 mm.
depth72 mm.
height96 mm.
net weight450 g.
Environment
electromagnetic compatibilityLimits for harmonic current emissions, class A, conforming to IEC 61000-3-2.
Conducted RF disturbances level 3, conforming to IEC 61000-4-6.
Magnetic field at power frequency level 4 conforming to IEC 61000-4-8.
Conducted and radiated emissions in class B, conforming to EN 55022.
Limitation of voltage changes, voltage fluctuations, and flicker in low-voltage conforming to IEC 61000-3-3.
Electrostatic discharge, test level: 8 kV, level 4, conforming to IEC 61000-4,-2.
Radiated radio-frequency electromagnetic field. immunity test conforming to IEC 61000-4-3.
Electrical fast transient/burst immunity test level 4, conforming to IEC 61000-4-4.
Surge immunity test level 4 conforming to IEC 61000-4-5.
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11.
IP degree of protectionIP52 front: conforming to IEC 60529.
IP30 body: conforming to IEC 60529.
relative humidity5… 95%% at 50 °C.
pollution degree2
ambient air temperature for operation-25…70 °C.
ambient air temperature for storage-40…85 °C.
operating altitude3000 m.
Packing Units
Unit Type of Package 1PCE.
Number of Units in Package 11
Package 1: Weight996 g.
Package 1: Height15.2 cm.
Package: 1 width12.3 cm
Package 1 Length17.2 cm
Unit Type of Package 2BB1
Number of Units in Package 21
Package 2: Weight980 g
Package 2: Height15 cm.
Package 2 width17.5 cm.
Package 2 Length12.5 cm.
Unit Type of Package 3P12.
Number of Units in Package 324.
Package 3: Weight22000 g
Package 3: Height1050 mm.
Package 3 width800 mm.
Package 3 Length1200 mm
Offer Sustainability
Sustainable offer statusGreen Premium product.
REACh RegulationREACh Declaration.
EU RoHS Directive
Compliant

EU RoHS Declaration.

Mercury freeYes
RoHS exemption informationYes
China’s RoHS RegulationChina RoHS declaration.
Environmental DisclosureProduct Environmental Profile.
Circularity ProfileEnd-of-life information.
WEEEThe product must be disposed on European Union markets. following specific waste collection and never end up in rubbish bins.