Sale!

59658 – 2 Ethernet ports interface 10/100BASE-TX

Original price was: $617.00.Current price is: $575.00.

10 in stock

Category:

Description

Main
Range of productSepam series 40.
Sepam series 80 NPP.
Sepam series 60.
Sepam series 80.
Device short nameACE850TP.
Complementary
communication port protocolARP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX.
FTP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX.
HTTP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX.
IEC 61850 network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX.
Modbus RTU network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX.
Modbus TCP/IP network: S-LAN and E-LAN.. interface: 2 Ethernet ports 10/100BASE-TX.
RSTP 801.1d 2004 network: S-LAN and E-LAN. interface: 2 Ethernet ports 10/100BASE-TX..
SNMP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX.
SNTP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX.
local signallingGreen LED1 for energized (front face).
Green LED2 for communication status ok (front face).
Green LED3 off for port 2 Ethernet 10 Mbit/s (front face).
Green LED3 on for port 2 Ethernet 100 Mbit/s (front face).
Green LED4 flashing. for port 2 Ethernet sending data and receiving data (front face).
Green LED5 off for port 1 Ethernet 10 Mbit/s (front face).
Green LED5 on for port 1 Ethernet 100 Mbit/s (front face).
Green LED6 flashing for port 1 Ethernet sending data and receiving data (front face).
Red LED1 flashing for not set up or not base-unit connected (front face).
Red LED1 off for de-energized (front face).
Red LED1 remains ON for fault (front face).
[Us] rated supply voltage110…240 V AC tolerance: – 20…10 %.
24…250 V DC tolerance: – 20…10 %.
Mounting modeFixed.
Mounting supportSymmetrical DIN rail.
Height127 mm.
Width171 mm.
Depth58 mm.
Product weight0.4 kg.
mechanical robustnessEarthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3.
Earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3.
Jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2.
Shocks de-energized (level: 2) : 30 Gn/11 ms conforming to IEC 60255-21-2.
Shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2.
Vibrations de-energized (level: 2) : 2 Gn, 10 Hz, 150 Hz, conforming to IEC 60255-21-1.
Vibrations in operation (level: 2) : 1 Gn, 10 Hz, 150 Hz, conforming to IEC 60255-21-1.
Vibrations in operation (level: Fc) : 2 Hz–13.2 Hz, a = +/- 1 mm, conforming to IEC 60068-2-6.
maximum cable distance between devices<100 m.
auxiliary connection terminalFunctional earth: ring lug 1 pin(s) 1 cable(s) tinned copper braid 4 mm².
Protective earth: screw-type connector 1 pin(s) 1 cable(s) wire 2.5 mm² <3 m.
Supply: screw-type connector 3 pin(s) 1 cable(s) wire 0.5…2.5 mm².
Supply: screw-type connector 3 pin(s) 1 cable(s) wire 1.5 mm².
Supply: screw-type connector 3 pin(s) 1 cable(s) wire 2.5 mm²
Supply: screw-type conne.ctor 3 pin(s) 2 cable(s) wire 0.5…1 mm².
Supply: screw-type connector 3 pin(s) 2 cable(s) wire 1 mm².
Supply: screw-type connector 4 pin(s) 1 cable(s) wire 0.5…2.5 mm².
Supply: screw-type connector 4 pin(s) 1 cable(s) wire 1.5 mm².
Supply: screw-type connector 4 pin(s) 1 cable(s) wire 2.5 mm².
Supply: screw-type connector 4 pin(s) 2 cable(s) wire 0.5…1 mm².
Supply: screw-type connector 4 pin(s) 2 cable(s) wire 1 mm².
wire stripping lengthSupply: 8 mm.
Environment
electromagnetic compatibility1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC and MD, conforming to ANSI C37.90.1.
1 MHz damped oscillating wave: (immunity tests-conducted disturbances), III, 2.5 kV MC, 1 kV MD, conforming to IEC 60255-22-1.
100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC, 1 kV MD, conforming to IEC 61000-4-12.
Conducted disturbance emission: (emission tests), conforming to IEC 60255-25.
Conducted disturbance emission: (emission tests), B, conforming to EN 55022.
Disturbing field emission: (emission tests), conforming to IEC 60255-25.
Disturbing field emission: (emission tests), A, conforming to EN 55022.
Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3.
Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2.
Fast transient bursts: (immunity tests-conducted. disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1
Fast transient bursts: (immunity tests-conducted. disturbances), A or B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4.
Fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4.
Immunity to conducted RF disturbances: (immunity tests-conducted disturbances), 10 V, conforming to IEC 60255-22-6.
Immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m. (continuous)-300 A/m (13 s), conforming to IEC 61000-4-8
Immunity to radiated fields: (immunity tests-radiated. disturbances), 10 V/m, 80 MHz…1 GHz, conforming to IEC 60255-22-3.
Immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz…1 GHz, conforming to ANSI C37.90.2 (1995).
Immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz…2 GHz, conforming to IEC 61000-4-3.
Surges: (immunity tests-conduct.ed disturbances), III, 2 kV MC, 1 kV MD, conforming to IEC 61000-4-5.
Voltage interruptions: (immunity tests-conducted. disturbances), 100 %, 10 ms, conforming to IEC 60255-11.
climatic withstandInfluence of corrosion/gaz test 4 (in operation) : 21 days, 75. % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.02 ppm NO2, 0.01 ppm Cl2 conforming to IEC 60068-2-60
Continuous exposure to damp heat (in operation): Ca: 10 days, 93% RH, 40 °C (104 °F), conforming to IEC 60068-2-3.
Continuous exposure to damp heat (in storage): Ca: 56 days, 93% RH, 40 °C (104 °F), conforming to IEC 60068-2-3.
Exposure to cold (in operation): Ab: -25 °C (-13 °F) conforming to IEC 60068-2-1.
Exposure to cold (in storage): Ab: -25 °C (-13 °F) conforming to IEC 60068-2-1.
Exposure to dry heat (in operation): Bb: 70 °C (158 °F) conforming to IEC 60068-2-2.
Exposure to dry heat (in storage) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2.
Influence of corrosion/gaz test 2 (in operation) : C: 21 days, 75 % RH, 25 °C (- 13 °F), 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60.
Salt mist (in operation) : Kb/2 conforming to IEC 60068-2-52.
Temperature variation with specified variation rate (in operation) : Nb: – 25 °C to 70 °C (- 13 °F to 158 °F) 5. °C/min (41 °F/min) conforming to IEC 60068-2-14.
Ambient air temperature for operation-25…70 °C.
Packing Units
Unit Type of Package 1PCE.
Number of Units in Package 11
Package 1 Height9.800 cm.
Package 1 Width16.700 cm.
Package 1 Length19.800 cm.
Package 1 Weight721 g
Unit Type of Package 2S03
Number of Units in Package 26
Package 2 Height30.000 cm.
Package 2 Width30.000 cm.
Package 2 Length40.000 cm.
Package 2 Weight4.733 kg.
Unit Type of Package 3P12
Number of Units in Package 348
Package 3 Height44.500 cm.
Package 3 Width80.000 cm.
Package 3 Length120.000 cm.
Package 3 Weight49.784 kg.