ATS48C14Y – soft starter for asynchronous motor
Original price was: $3,552.00.$2,732.00Current price is: $2,732.00.
The ATS48C14Y is a versatile soft starter for asynchronous motors, offering smooth and controlled acceleration and deceleration.
1 in stock
Free shipping on orders over $5000!
- Satisfaction Guaranteed
- No Hassle Refunds
- Secure Payments
Description
range of product | Altistart 48. |
---|---|
product or component type | Soft starter. |
product destination | Asynchronous motors. |
product-specific application | Heavy-duty industry and pumps. |
device’s short name | ATS48. |
power supply voltage | 208…690 V = 15…10 %. |
motor power kW | 110 kW at 660 V for standard applications. 110 kW at 690 V for standard applications. 30 kW at 230 V for severe applications. 37 kW at 230 V for standard applications. 55 kW at 400 V for severe applications. 55 kW at 440 V for severe applications. 75 kW at 400 V for standard applications. 75 kW at 440 V for standard applications. 75 kW at 500 V for severe applications. 75 kW at 525 V for severe applications. 90 kW at 500 V for standard applications. 90 kW at 525 V for standard applications. 90 kW at 660 V for severe applications. 90 kW at 690 V for severe applications. |
motor power hp | 100 hp at 460 V for standard applications. 100 hp at 575 V for severe applications. 125 hp at 575 V for standard applications. 30 hp at 208 V for severe applications. 40 hp at 208 V for standard applications. 40 hp at 230 V for severe applications. 50 hp at 230 V for standard applications. 75 hp at 460 V for severe applications. |
power dissipation in W | 306 W for standard applications. 391 W for standard applications. |
utilisation category | AC-53A. |
type of start | Start with torque control (currently limited to 5 inches). |
Icl nominal current | 140 A for connection in the motor supply line for severe applications. 140 A for connection in the motor supply line for standard applications. |
assembly style | With a heat sink. |
---|---|
function available | External bypass (optional). |
power supply frequency | 50…60 Hz, 5…5%. |
power supply frequency limits | 47.5…63 Hz. |
device connection | In the motor supply line. |
discrete output number | 2 |
discrete output type | (LO1) logic output 0 V is common configurable. (LO2) logic output 0 V is common configurable. (R1) relay outputs fault relay NO. (R2) relay outputs the end of starting relay NO. (R3) relay outputs motor-powered NO. |
output absolute accuracy precision | +/- 5 % |
minimum switching current | 10 mA at 6 V DC for relay outputs. |
maximum switching current | Logic output: 0.2 A at 30 V DC. Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 ms. Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 ms. |
discrete input number | 5 |
discrete input type | PTC, 750 Ohm at 25 °C. (Stop, Run, LI3, LI4) logic, <= 8 mA, 4300 Ohm. |
discrete input voltage | 24 V <= 30 V. |
discrete input logic | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA. |
starting current | 0.4…1.3 Icl adjustable |
analogue output type | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm. |
communication port protocol | Modbus. |
connector type | 1 RJ45. |
communication data link | Serial |
physical interface | RS485 multidrop. |
transmission rate | 4800, 9600 or 19200 bps. |
max nodes number | 31 |
protection type | Phase failure: line. Thermal protection: motor. Thermal protection: starter. |
marking | CE. |
operating position | Vertical +/- 10 degrees. |
height | 340 mm. |
width | 200 mm. |
depth | 265 mm. |
net weight | 12.4 kg. |
Motor power range: AC-3 | 30…50 kW at 200…240 V, 3 phases. 55…100 kW at 380…440 V, 3 phases. 55…100 kW at 480…500 V, 3 phases. |
motor starter type | Soft starter. |
electromagnetic compatibility | Conducted and radiated emissions at level A, conforming to IEC 60947-4-2. Conducted and radiated emissions level B, conforming to IEC 60947-4-2. Damped oscillating waves, level 3, conforming to IEC 61000-4-12. Electrostatic discharge level 3 conforms to IEC 61000-4-2. Immunity to electrical transients, level 4, conforming to IEC 61000-4-4. Immunity to radiated radio-electrical interference level 3 conforms to IEC 61000-4-3. Voltage/current impulse level 3 conforms to IEC 61000-4-5. |
---|---|
standards | EN/IEC 60947-4-2. |
product certifications | UL C-Tick CSA TCF CCC NOM 117 DNV GOST SEPRO |
noise level | 50 dB |
relative humidity | 0…95 % without condensation or dripping water, conforming to EN/IEC 60068-2-3. |
ambient air temperature for operation | 40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating). |
ambient air temperature for storage | -25…70 °C |
operating altitude | <= 1000 m without derating. > 1000–2000 m with current derating of 2.2 % per additional 100 m. |
Unit Type of Package 1 | PCE. |
---|---|
Number of Units in Package 1 | 1 |
Package 1: Weight | 14.892 kg. |
Package 1: Height | 34 cm |
Package: 1 width | 43 cm |
Package 1 Length | 46 cm |
Sustainable offer status | Green premium product. |
---|---|
REACh Regulation | REACh Declaration. |
EU RoHS Directive |
Pro-active compliance. (Product out of EU RoHS legal scope)
EU RoHS Declaration. |
Mercury free | Yes |
RoHS exemption information | Yes |
China RoHS Regulation | China RoHS declaration. |
Environmental Disclosure | Product Environmental Profile. |
Circularity Profile | End-of-life information. |
WEEE | The product must be disposed of on European Union markets following specific waste collection procedures and never end up in rubbish bins. |
California proposition 65 | Warning: This product can expose you to chemicals, including lead and lead compounds, which are known to the State of California to cause cancer, birth defects, or other reproductive harm. |