Description
| range of product | Harmony Relay RM4TR32. | |
|---|---|---|
| product or component type | Industrial measurement and control relays. | |
| relay type | Control relay. | |
| product-specific application | ||
| relay name | RM4-T. | |
| relay monitored parameters | Phase failure detection. Phase sequence. Overvoltage and undervoltage detection. | |
| time delay | Adjustable 0.1…10 s. | |
| measurement range | 290…484 V. | |
| contacts type and composition | 2 C/O. | |
| poles description | 3P. |
| maximum switching voltage | 440 V AC. | |
|---|---|---|
| control threshold undervoltage | 300…430 V. | |
| control threshold overvoltage | 420…480 V. | |
| output contacts | 2 C/O. | |
| setting accuracy of the switching threshold | +/-3 %. | |
| switching threshold drift | <= 0.06 % per degree centigrade, depending. permissible ambient air temperature. <= 0.5 % within the measuring range. | |
| setting accuracy of time delay | 10 P. | |
| time delay drift | <= 0.07 % per degree Celsius, depending on. the rated operational temperature. <= 0.5 % within the measuring range. | |
| hysteresis | 5 % fixed of de-energization threshold. | |
| delay at power up | 650 ms. | |
| maximum measuring cycle | 80Â ms | |
| marking | CE. | |
| overvoltage category | III, conforming to IEC 60664-1. | |
| [Ui] rated insulation voltage | 500 V, conforming to the IEC. | |
| supply frequency | 50/60 Hz +/- 5%. | |
| operating position | Any position without derating. | |
| connections—terminals | Screw terminals, 2 x 1.5 mm flexible with cable end. Screw terminals, 2 x 2.5 mm flexible without cable ends. | |
| tightening torque | 0.6…1.1 N.m. | |
| mechanical durability | 30000000 cycles. | |
| conventional free-air thermal current | 8 A. | |
| [Ie] rated operational current | 2 A at 70 °C, 24 V DC-13, conforming to IEC 60947-5-1/1991. 2 A at 70 °C, 24 V DC-13, conforming to VDE 0660. 3 A at 70 °C, 115 V AC-15, conforming to IEC. 60947-5-1/1991. 3 A at 70 °C, 115 V AC-15, conforming to VDE 0660. 3 A at 70 °C, 24 V AC-15, conforming to IEC 60947-5-1/1991. 3 A at 70 °C, 24 V AC-15, conforming to VDE 0660. 3 A at 70 °C 250 V AC-15 conforming to IEC. 60947-5-1/1991. 3 A at 70 °C 250 V AC-15 conforming to VDE. 0660. 0.1 A at 70 °C 250 V DC-13 conforming to IEC. 60947-5-1/1991. 0.1 A at 70 °C 250 V DC-13 conforming to VDE 0660. 0.3 A at 70 °C 115 V DC-13 conforming to IEC 60947-5-1/1991. 0.3 A at 70 °C 115 V DC-13 conforming to VDE 0660. | |
| switching capacity in mA | 10 mA at 12 V. | |
| switching voltage | 250 V AC. | |
| contacts material | 90/10 silver nickel contacts. | |
| number of cables | 2 | |
| height | 78 mm. | |
| width | 22.5 mm. | |
| depth | 80 mm. | |
| terminals description: ISO n°1 | (15-16-18)OC. (L1-L2-L3)CO. (25-26-28)OC. | |
| output relay state | Tripped, fault present. | |
| 9 mm pitches | 2.5. | |
| net weight | 0.11 kg. |
| electromagnetic compatibility | Electrostatic discharge – test level: 6 kV level 3. (contact discharge) conforming to IEC 61000-4-2. Electrostatic discharge – test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2. Resistance to electrostatic discharge – test level: 6 kV (contact) conforming to IEC 61000-4-2 level 3. Resistance to electrostatic discharge – test level: 8. kV (air) conforming to IEC 61000-4-2 level 3. | |
|---|---|---|
| standards | EN/IEC 60255-6. | |
| product certifications | CSA GL. UL | |
| directives | 73/23/EEC – low voltage directive. 89/336/EEC – electromagnetic compatibility. | |
| ambient air temperature for storage | -40…85 °C | |
| ambient air temperature for operation | -20…65 °C. | |
| relative humidity | 15…85 % 3K3 conforming to IEC 60721-3-3. | |
| vibration resistance | 0.35 ms (f= 10…55 Hz) conforming to IEC 60068-2-6. | |
| shock resistance | 15 gn for 11 ms, conforming to IEC 60068-2-27. | |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529. IP50 (casing) conforming to IEC 60529. | |
| pollution degree | conforming to IEC 60664-1. | |
| dielectric test voltage | 2.5Â kV | |
| non-dissipating shock wave | 4.8Â kV | |
| resistance to electrostatic discharge | 6 kV contact conforming to IEC 61000-4-2 level 3. 8 kV air conforming to IEC 61000-4-2 level 3. | |
| resistance to electromagnetic fields | 10 V/m conforming to IEC 61000-4-3 level 3. | |
| resistance to fast transients | 2 kV, conforming to IEC 61000-4-4 level 3. | |
| disturbance radiated/conducted | CISPR 11 group 1 – class A. CISPR 22: Class A. |