ATV212HU40N4 Schneider Electric
$776.00 Original price was: $776.00.$597.00Current price is: $597.00.
The Schneider Electric ATV212HU40N4 is a versatile variable frequency drive (VFD) designed for industrial applications.
5 in stock
Free shipping on orders over $5000!
- Satisfaction Guaranteed
- No Hassle Refunds
- Secure Payments
Category: SOFT STARTERS
Description
device short name | ATV212. |
---|---|
Product destination | Asynchronous motors. |
Network number of phases | 3 phases. |
Motor power kW | 4 kW. |
Motor power hp | 5 hp |
Supply voltage limits | 323…528 V. |
Supply frequency | 50…60 Hz – 5…5 %. |
Line current | 6.4 A at 480 V. 8.1 A at 380 V. |
Range of product | Altivar 212 |
Product or component type | Variable-speed drive. |
Product-specific application | Pumps and fans in HVAC. |
communication port protocol | METASYS N2. BACnet. APOGEE FLN. Modbus. LonWorks. |
[Us] rated supply voltage | 380…480 V = 15…10%. |
EMC filter | Class C2 EMC filter integrated. |
IP degree of protection | IP21 |
Apparent power | 6.9 kVA at 380 V. |
---|---|
Continuous output current | 9.1 A at 380 V. 9.1 A at 460 V. |
Maximum transient current | 10 A for 60 s. |
Speed drive output frequency | 0.5…200 Hz. |
Speed range | 1…10 |
Speed accuracy | +/- 10% of nominal slip 0.2 Tn to Tn. |
Local signalling | 1 LED (red) for the DC bus is energized. |
Output voltage | <power supply voltage. |
isolation | Electrical between power and control. |
Type of cable | Without mounting kit: 1 wire(s) of IEC cable at 45 °C, copper at 90 °C, XLPE, or EPR. Without mounting kit: 1 wire(s) of IEC cable at 45 °C, copper at 70 °C, / PVC. With UL Type 1 kit: 3 wire(s) UL 508 cable at 40 °C, copper 75 °C, / PVC. |
Electrical connection | VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm2 / AWG 14. L1/R, L2/S, L3/T: terminal 6 mm²/AWG 10. |
Tightening torque | 1.3 N.m., 11.5 lb.in. (L1/R, L2/S, L3/T). 0.6 N.m. (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES). |
Supply | Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5%, <10 A, protection type: overload and short-circuit protection. Internal supply: 24 V DC (21…27 V), <200 A; protection type: overload and short-circuit protection. |
Sampling duration | 2 ms +/- 0.5 ms F discrete. 2 ms +/- 0.5 ms R discrete. 2 ms +/- 0.5 ms RES discrete. 3.5 ms +/- 0.5 ms VIA analog. 22 ms +/- 0.5 ms VIB analog. |
Response time | FM 2 ms, tolerance +/- 0.5 ms for analog output(s). FLA, FLC, 7 ms, tolerance +/- 0.5 ms for discrete. output(s). FLB, FLC, 7 ms, tolerance +/- 0.5 ms for discrete output(s). RY, RC, 7 ms, tolerance +/- 0.5 ms for discrete output(s). |
Accuracy | +/- 0.6% (VIA) for a temperature variation of 60 °C. +/- 0.6% (VIB) for a temperature variation of 60 °C. +/- 1% (FM) for a temperature variation of 60 °C. |
Linearity error | VIA: +/- 0.15% of the maximum value for input. VIB: +/- 0.15% of the maximum value for input. FM: +/- 0.2% for output. |
Analogue output type | FM switch-configurable voltage: 0…10 V DC, impedance: 7620 Ohm, resolution: 10 bits. FM switch-configurable current: 0…20 mA, impedance: 970 Ohm, resolution: 10 bits. |
Discrete output type | Configurable relay logic: (FLA, FLC) NO: 100000 cycles. Configurable relay logic: (FLB, FLC) NC: 100000 cycles. Configurable relay logic: (RY, RC) NO: 100000 cycles. |
Minimum switching current | 3 mA at 24 V DC for configurable relay logic. |
Maximum switching current | 5 A at 250 V AC on resistive load – cos phi = 1 – L/R = 0 ms (FL, R). 5 A at 30 V DC on resistive load – cos phi = 1 – L/R = 0 ms (FL, R). 2 A at 250 V AC on inductive load: cos phi = 0.4; L/R = 7 ms (FL, R). 2 A at 30 V DC on inductive load: cos phi = 0.4; L/R = 7 ms (FL, R). |
Discrete input type | F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm. R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm. RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm. |
Discrete input logic | Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1). Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1). |
Dielectric strength | 3535 V DC between earth and power terminals. 5092 V DC between control and power terminals. |
Insulation resistance | >= 1 mOhm 500 V DC for 1 minute. |
Frequency resolution | Display unit: 0.1 Hz. Analog input: 0.024/50 Hz. |
communication service | Write multiple registers (16)—two words maximum. Time out setting from 0.1 to 100 s. Read device identification (43). Monitoring inhibitable. Read holding registers (03) 2 words maximum. Write single register (06). |
Option card | Communication card for LonWorks. |
Power dissipation in W | 176 W |
Air flow | 60 m3/h |
Functionality | Mid |
Specific application | HVAC |
Variable speed drive application selection | Building: HVAC compressor for scroll. Building: HVAC fan. Building: HVAC pump. |
Motor power range: AC-3 | 4…6 kW at 380…440 V in 3 phases. 4…6 kW at 480…500 V in 3 phases. |
Motor starter type | Variable-speed drive. |
Discrete output number | 2 |
Analogue input number | 2 |
Analogue input type | VIA switch-configurable voltage: 0…10 V DC, 24 V max, impedance: 30000 Ohm, resolution: 10 bits. VIB configurable voltage: 0…10 V DC, 24 V max, impedance: 30000 Ohm, resolution: 10 bits. VIB configurable PTC probe: 0…6 probes, impedance: 1500 Ohm. VIA switch-configurable current: 0…20 mA, impedance: 250 Ohm, resolution: 10 bits. |
Analogue output number | 1 |
Physical interface | 2-wire RS 485. |
connector type | 1 open style. 1 RJ45. |
Transmission rate | 9600 bps or 19200 bps. |
Transmission frame | RTU. |
Number of addresses | 1…247. |
Data format | 8 bits, 1 stop, odd, even, or no configurable parity. |
Types of polarization | No impedance. |
Asynchronous motor control profile | Voltage/frequency ratio: energy Energy Saving, quadratic U/f Voltage/frequency ratio, automatic IR compensation (U/F + automatic Uo). Voltage/frequency ratio: 2 points. Voltage/frequency ratio: 5 points. Flux vector control without sensor, standard. |
Torque accuracy | +/- 15%. |
Transient overtorque | 120 % of nominal motor torque +/- 10 % for 60 s. |
Acceleration and deceleration ramps | Linear is adjustable separately from 0.01 to 3200 s. Automatic based on the load. |
Motor slip compensation | Automatic, whatever the load Adjustable. Not available in voltage/frequency ratio motor control. |
Switching frequency | 6–16 kHz is adjustable. 12–16 kHz with a derating factor. |
Nominal switching frequency | 12 kHz. |
Braking to standstill | By DC injection. |
Network frequency | 47.5…63 Hz. |
Prospective line Isc | 5 kA |
Protection type | Overheating protection: drive. Thermal power stage: drive. Short-circuit between motor phases: drive. Input phase breaks: drive. Overcurrent between output phases and earth: drive. Overvoltages on the DC bus: drive. Break on the control circuit: drive. Against exceeding the limit speed: drive. Line supply overvoltage and undervoltage: drive. Line supply undervoltage: drive. Against input phase loss: drive. Thermal protection: motor. Motor phase break: motor. With PTC probes: motor. |
Width | 142 mm. |
Height | 184 mm. |
Depth | 150 mm. |
Net weight | 3.35 kg. |
Pollution degree | conforming to IEC 61800-5-1. |
---|---|
IP degree of protection | IP20 on the upper part without a blanking plate on the cover. conforming to EN/IEC 61800-5-1. IP20 on the upper part without a blanking plate on the cover. conforming to EN/IEC 60529. IP21 conforms to EN/IEC 61800-5-1. IP21 conforms to EN/IEC 60529. IP41 on the upper part conforms to EN/IEC 61800-5-1. IP41 on the upper part conforms to EN/IEC 60529. |
Vibration resistance | 1.5 mm (f = 3…13 Hz) conforming to EN/IEC 60068-2-6. 1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-8. |
Shock resistance | 15 gn for 11 ms, conforming to IEC 60068-2-27. |
Environmental characteristic | Classes 3C1 conform to IEC 60721-3-3. Classes 3S2 conform to IEC 60721-3-3. |
Noise level | 51 dB, conforming to 86/188/EEC. |
Operating altitude | 1000–3000 m, limited to 2000 m for the corner. grounded distribution network with current derating 1% per 100 m. <= 1000 m without derating. |
Relative humidity | 5…95% without condensation, conforming to IEC. 60068-2-3. 5% without dripping water, according to IEC 60068-2-3. |
Ambient air temperature for operation | -10…40 °C (without derating). 40…50 °C (with derating factor). |
Operating position | Vertical +/- 10 degrees. |
product certifications | CSA. NOM 117. UL C-Tick. |
Marking | CE |
Standards | IEC 61800-3 environments, category C2. IEC 61800-3 environments, category C1. IEC 61800-3 environments, 1 category C3. IEC 61800-3 environments 2 category C3. IEC 61800-3, category C3. EN 61800-3 environments 1 category C1. IEC 61800-3, category C2. EN 61800-3. EN 61800-3 Environments, Category C3. EN 61800-3 environments, 2 category C2. UL Type 1. IEC 61800-3. EN 61800-3 environments, 2 category C1. IEC 61800-3 environments, 1 category C2. EN 61800-3 environments, 2 category C3. EN 55011, class A, group 1. EN 61800-3, category C2. EN 61800-3 environments, 1 category C2. IEC 61800-3 environments 2 category C1. IEC 61800-5-1. EN 61800-5-1. EN 61800-3, category C3. |
Assembly style | With a heat sink. |
Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforms to IEC 61000-4-2. Radiated radio-frequency electromagnetic field immunity test level 3 conforms to IEC 61000-4-3. Electrical fast transient/burst immunity test level 4 conforms to IEC 61000-4-4. 1.2/50 µs–8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5. Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6. The voltage dips and interruptions immunity test conforms to IEC 61000-4-11. |
Regulation loop | Adjustable PI regulator. |
Ambient air temperature for storage | -25…70 °C. |
Unit Type of Package 1 | PCE. |
---|---|
Number of Units in Package 1 | 1 |
Package 1: Height | 25.000 cm. |
Package 1: Width | 25.000 cm. |
Package 1 Length | 24.000 cm. |
Package 1: Weight | 3.078 kg. |
Unit Type of Package 2 | P06. |
Number of Units in Package 2 | 12 |
Package 2: Height | 75.000 cm. |
Package 2 Width | 60.000 cm. |
Package 2 Length | 80.000 cm. |
Package 2: Weight | 49.312 kg. |
Related products
-
Sale!
ATS48D22Y Schneider Electric
$1,283.00Original price was: $1,283.00.$987.00Current price is: $987.00. -
Sale!
ATS48D32Y Schneider Electric
$1,361.00Original price was: $1,361.00.$1,062.00Current price is: $1,062.00. -
Sale!
ATS48D47Y Schneider Electric
$1,797.00Original price was: $1,797.00.$1,382.00Current price is: $1,382.00.