Main
RANGE OF PRODUCTTeSys Deca
PRODUCT OR COMPONENT TYPEContactor
DEVICE SHORT NAMELC1D
CONTACTOR APPLICATIONMotor control.
Resistive load.
UTILISATION CATEGORYAC-3.
AC-4.
AC-1.
AC-3e.
POLES DESCRIPTION3P
[UE] RATED OPERATIONAL VOLTAGEPower circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC.
[IE] RATED OPERATIONAL CURRENT9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit.
25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit.
9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit.
[UC] CONTROL CIRCUIT VOLTAGE240 V AC, 50/60 Hz.
Complementary
MOTOR POWER KW2.2 kW at 220…230 V AC 50/60 Hz (AC-3).
4 kW at 380…400 V AC 50/60 Hz (AC-3).
4 kW at 415…440 V AC 50/60 Hz (AC-3).
5.5 kW at 500 V AC 50/60 Hz (AC-3).
5.5 kW at 660…690 V AC 50/60 Hz (AC-3).
2.2 kW at 400 V AC 50/60 Hz (AC-4).
2.2 kW at 220…230 V AC 50/60 Hz (AC-3e).
4 kW at 380…400 V AC 50/60 Hz (AC-3e).
4 kW at 415…440 V AC 50/60 Hz (AC-3e).
5.5 kW at 500 V AC 50/60 Hz (AC-3e).
5.5 kW at 660…690 V AC 50/60 Hz (AC-3e).
MOTOR POWER HP1 hp at 230/240 V AC 50/60 Hz for 1-phase motors.
2 hp at 200/208 V AC 50/60 Hz for 3-phase motors.
2 hp at 230/240 V AC 50/60 Hz for 3-phase motors.
5 hp at 460/480 V AC 50/60 Hz for 3-phase motors.
7.5 hp at 575/600 V AC 50/60 Hz for 3-phase motors.
0.33 hp at 115 V AC 50/60 Hz for 1-phase motors.
COMPATIBILITY CODELC1D.
POLE CONTACT COMPOSITION3 NO.
CONTACT COMPATIBILITYM2
PROTECTIVE COVERWith
[ITH] CONVENTIONAL FREE AIR THERMAL CURRENT25 A (at 60 °C) for power circuit.
10 A (at 60 °C) for the signaling circuit.
IRMS RATED MAKING CAPACITY250 A at 440 V for power circuit conforming to IEC 60947.
140 A AC for signalling circuit conforming to IEC 60947-5-1.
250 A DC for the signaling circuit conforming to IEC 60947-5-1.
RATED BREAKING CAPACITY250 A at 440 V for power circuit conforming to IEC 60947.
[ICW] RATED SHORT-TIME WITHSTAND CURRENT105 A 40 °C, 10 s for power circuit.
210 A 40 °C, 1 s for power circuit.
30 A 40 °C, 10 min for power circuit.
61 A 40 °C, 1 min for power circuit.
100 A – 1 s for signalling circuit.
120 A – 500 ms for the signaling circuit.
140 A to 100 ms for the signaling circuit.
ASSOCIATED FUSE RATING10 A gG for the signaling circuit conforming to IEC 60947-5-1.
25 A gG at <= 690 V coordination type 1 for power circuit.
20 A gG at <= 690 V coordination type 2 for power circuit.
AVERAGE IMPEDANCE2.5 mOhm (25 A, 50 Hz) for power circuit.
POWER DISSIPATION PER POLE1.56 W AC-1.
0.2 W AC-3.
0.2 W AC-3e.
[UI] RATED INSULATION VOLTAGEPower circuit: 690 V, conforming to IEC 60947-4-1.
Power circuit: 600 V, CSA-certified.
Power circuit: 600 V, UL certified.
Signaling circuit: 690 V, conforming to IEC 60947-1.
Signaling circuit: 600 V CSA-certified.
Signaling circuit: 600 V UL certified
OVERVOLTAGE CATEGORYIII
POLLUTION DEGREE3
[UIMP] RATED IMPULSE WITHSTAND VOLTAGE6 kV, conforming to IEC 60947
SAFETY RELIABILITY LEVELB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1.
B10d = 20000000 cycles contactor with, mechanical load conforming to EN/ISO 13849-1.
MECHANICAL DURABILITY15 Mcycles.
ELECTRICAL DURABILITY0.6 Mcycles 25 A AC-1 at Ue <= 440 V.
2 Mcycles 9 A AC-3 at Ue <= 440 V.
2 Mcycles 9 A AC-3e at Ue <= 440 V.
CONTROL CIRCUIT TYPEAC at 50/60 Hz.
COIL TECHNOLOGYWithout built-in suppressor module.
CONTROL CIRCUIT VOLTAGE LIMITS0.3…0.6 Uc (-40…70 °C): drop-out AC 50/60 Hz.
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz.
0.85…1.1 Uc (-40…60 °C): operational AC 60 Hz.
1…1.1 Uc (60…70 °C): operational AC 50/60 Hz.
INRUSH POWER IN VA70 VA 60 Hz, cos phi 0.75 (at 20 °C).
70 VA 50 Hz, cos phi 0.75 (at 20 °C).
HOLD-IN POWER CONSUMPTION IN VA7.5 VA 60 Hz, cos phi 0.3 (at 20 °C).
7 VA 50 Hz, cos phi 0.3 (at 20 °C).
HEAT DISSIPATION2…3 W at 50/60 Hz.
OPERATING TIME12…22 ms closing.
4…19 ms opening.
MAXIMUM OPERATING RATE3600 cyc/h, 60 °C.
CONNECTIONS AND TERMINALSPower circuit: screw clamp terminals 1 1/4 mm²; cable stiffness: flexible without cable end.
Power circuit: screw clamp terminals 2 1/4 mm²; cable stiffness: flexible without cable end.
Power circuit: screw clamp terminals 1 1/4 mm²; cable stiffness: flexible with cable end.
Power circuit: screw clamp terminals 2 1…2.5 mm²; cable stiffness: flexible with cable end.
Power circuit: screw clamp terminals 1 1/4 mm²; cable stiffness: solid without cable end.
Power circuit: screw clamp terminals 2 1/4 mm²; cable stiffness: solid without cable end.
Control circuit: screw clamp terminals 1 1/4. mm²; cable stiffness: flexible without cable end.
Control circuit: screw clamp terminals 2 1/4. mm²; cable stiffness: flexible without cable end.
Control circuit: screw clamp terminals 1 1/4. mm²; cable stiffness: flexible with cable end.
Control circuit: screw clamp terminals 2 1…2.5. mm²; cable stiffness: flexible with cable end.
Control circuit: screw clamp terminals 1 1/4. mm²; cable stiffness: solid without cable end.
Control circuit: screw clamp terminals 2 1/4. mm²; cable stiffness: solid without cable end.
TIGHTENING TORQUEPower circuit: 1.7 N.m. on screw clamp. terminals with screwdriver flat Ø 6 mm.
Power circuit: 1.7 N.m. on screw clamp. terminals with screwdriver Philips No. 2.
Control circuit: 1.7 N.m. on screw clamp. terminals with screwdriver flat Ø 6 mm.
Control circuit: 1.7 N.m. on screw clamp. terminals with screwdriver Philips No. 2.
Control circuit: 1.7 N.m. on screw clamp. terminals, with screwdriver pozidriv No. 2.
Power circuit: 1.7 N.m. on screw clamp. terminals, with screwdriver pozidriv No. 2.
AUXILIARY CONTACT COMPOSITION1 NO + 1 NC
AUXILIARY CONTACTS TYPEType mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1.
type mirror contact 1 NC conforming to IEC 60947-4-1.
SIGNALLING CIRCUIT FREQUENCY25…400 Hz.
MINIMUM SWITCHING VOLTAGE17 V for the signaling circuit.
MINIMUM SWITCHING CURRENT5 mA for the signaling circuit.
INSULATION RESISTANCE> 10 MOhm for signalling circuit.
NON-OVERLAP TIME1.5 ms on de-energisation between NC and NO contact.
1.5 ms on energization between NC and NO contact.
MOUNTING SUPPORTRail
Plate
Environment
STANDARDSCSA C22.2 No. 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
PRODUCT CERTIFICATIONSBV
UL
GOST
CSA.
RINA
GL
LROS (Lloyds register of shipping).
CCC.
DNV
UKCA
IP DEGREE OF PROTECTIONIP20 front face conforming to IEC 60529.
PROTECTIVE TREATMENTTH conforming to IEC 60068-2-30.
CLIMATIC WITHSTANDConforming to IACS E10 exposure to damp heat.
conforming to IEC 60947-1 Annex Q. category D exposure to damp heat.
PERMISSIBLE AMBIENT AIR TEMPERATURE AROUND THE DEVICE-40…60 °C.
60…70 °C with derating.
OPERATING ALTITUDE0…3000 m.
FIRE RESISTANCE850 °C, conforming to IEC 60695-2-1.
FLAME RETARDANCEV1 conforming to UL 94.
MECHANICAL ROBUSTNESSVibrations contactor open (2 Gn, 5… 300 Hz).
Vibrations contactor closed (4 Gn, 5… 300 Hz).
Shocks contactor open (10 Gn for 11 ms).
Shocks contactor closed (15 Gn for 11 ms).
HEIGHT77 mm
WIDTH45 mm
DEPTH86 mm
NET WEIGHT0.32 kg
Packing Units
UNIT TYPE OF PACKAGE 1PCE
NUMBER OF UNITS IN PACKAGE 11
PACKAGE 1 HEIGHT5.0 cm
PACKAGE 1 WIDTH9.2 cm
PACKAGE 1 LENGTH11.2 cm
PACKAGE 1 WEIGHT352.0 g
UNIT TYPE OF PACKAGE 2S02
NUMBER OF UNITS IN PACKAGE 220
PACKAGE 2 HEIGHT15.0 cm
PACKAGE 2 WIDTH30.0 cm
PACKAGE 2 LENGTH40.0 cm
PACKAGE 2 WEIGHT7.426 kg
UNIT TYPE OF PACKAGE 3P06
NUMBER OF UNITS IN PACKAGE 3320
PACKAGE 3 HEIGHT77.0 cm
PACKAGE 3 WIDTH80.0 cm
PACKAGE 3 LENGTH60.0 cm
PACKAGE 3 WEIGHT127.316 kg