Main
RANGE OF PRODUCT Twido
PRODUCT OR COMPONENT TYPE Compact base controller.
CONCEPT Transparent Ready.
DISCRETE I/O NUMBER 40
DISCRETE INPUT NUMBER 24
DISCRETE INPUT VOLTAGE 24 V
DISCRETE INPUT VOLTAGE TYPE DC
DISCRETE OUTPUT NUMBER 14 for relay
2 for transistor.
[US] RATED SUPPLY VOLTAGE 100…240 V AC
MAXIMUM NUMBER OF I/O EXPANSION MODULE 7
USE OF SLOT Memory cartridge
DATA BACKED UP Internal RAM external battery (TSXPLP01), 3 years autonomy.
INTEGRATED CONNECTION TYPE Power supply.
Non isolated serial link mini DIN, Modbus/character. mode master/slave RTU/ASCII (RS485) half. duplex, 38.4 kbit/s.
Serial link interface adaptor (RS232C/RS485).
Ethernet TCP/IP RJ45, , 10/100 Mbit/s, 1 twisted pair transparent ready class A10.
COMPLEMENTARY FUNCTION PID
Event processing.
Complementary
DISCRETE INPUT LOGIC Sink or source
INPUT VOLTAGE LIMITS 20.4…26.4 V
DISCRETE INPUT CURRENT 11 mA for I0.0 to I0.1
11 mA for I0.6 to I0.7
7 mA for I0.2 to I0.5
7 mA for I0.8 to I0.23
INPUT IMPEDANCE 2100 Ohm for I0.0 to I0.1
2100 Ohm for I0.6 to I0.7
3400 Ohm for I0.2 to I0.5
3400 Ohm for I0.8 to I0.23
FILTER TIME 150 µs + programmed filter time for I0.6 to I0.23 at state 0.
35 µs + programmed filter time for I0.0 to I0.5 at state 1.
40 µs + programmed filter time for I0.0 to I0.5 at state 0.
40 µs + programmed filter time for I0.6 to I0.23 at state 1.
INSULATION BETWEEN CHANNEL AND INTERNAL LOGIC 1500 Vrms for 1 minute.
INSULATION RESISTANCE BETWEEN CHANNEL None
MINIMUM LOAD 0.1 mA
CONTACT RESISTANCE 30000 µOhm
LOAD CURRENT 2 A at 240 V AC inductive load, operating rate <30 cyc/mn for relay output.
2 A at 240 V AC resistive load, operating rate <30 cyc/mn for relay output.
2 A at 30 V DC inductive load, operating rate <30 cyc/mn for relay output.
2 A at 30 V DC resistive load, operating rate <30 cyc/mn for relay output.
MECHANICAL DURABILITY 20000000 cycles for relay output.
ELECTRICAL DURABILITY 100000 cycles for relay output.
CURRENT CONSUMPTION 128 mA at 24 V DC at state 1.
128 mA at 24 V DC state 1 + input ON.
170 mA at 5 V DC at state 0.
240 mA at 5 V DC state 1 + input ON.
5 mA at 24 V DC at state 0.
90 mA at 5 V DC at state 1.
I/O CONNECTION Non-removable screw terminal block.
MAXIMUM INPUT/OUTPUT NUMBER 152 removable screw terminal block with I/O expansion module.
208 spring terminal block with I/O. expansion module.
264 HE-10 connector with I/O expansion module.
NETWORK FREQUENCY 50/60 Hz
SUPPLY VOLTAGE LIMITS 85…264 V
NETWORK FREQUENCY LIMITS 47…63 Hz
POWER SUPPLY OUTPUT CURRENT 0.4 A for 24 V DC sensors.
INPUT CURRENT 790 mA
INRUSH CURRENT 35 A
PROTECTION TYPE Power protection by internal fuse.
POWER CONSUMPTION IN VA 65 VA at 100 V
77 VA at 264 V
INSULATION RESISTANCE > 10 MOhm at 500 V, between I/O and earth terminals.
> 10 MOhm at 500 V, between supply and earth terminals.
PROGRAM MEMORY 3000 instructions.
EXACT TIME FOR 1 KINSTRUCTION 1 ms
SYSTEM OVERHEAD 0.5 ms
MEMORY DESCRIPTION Internal RAM, 128 counters, no floating, no trigonometrical.
Internal RAM, 128 timers, no floating, no trigonometrical.
Internal RAM, 256 internal bits, no floating, no trigonometrical.
Internal RAM, 3000 internal words, no floating, no trigonometrical.
Internal RAM, double words, no floating, no trigonometrical.
Internal RAM, floating, trigonometrical
FREE SLOTS 1
REALTIME CLOCK With clock, clock drift <= 30 s/month, operating time: 30 days.
PORT ETHERNET 10BASE-T/100BASE-TX.
COMMUNICATION SERVICE BOOTP client, Ethernet TCP/IP.
Modbus messaging, Ethernet TCP/IP.
POSITIONING FUNCTIONS PWM/PLS 2 channel(s) at 7 kHz.
COUNTING INPUT NUMBER 2 counting input(s) at 20000 Hz, 32 bits.
4 counting input(s) at 5000 Hz, 16 bits.
ANALOGUE ADJUSTMENT POINTS 1 point, adjustable from 0 to 511 points.
1 point is adjustable from 0…1023.
STATUS LED 1 LED (green) PWR.
1 LED (green) RUN.
1 LED per channel (green) I/O status.
1 LED (red) module error (ERR).
1 LED user pilot light (STAT).
1 LED 10 or 100 Mbit/s rate (LACT).
1 LED Ethernet status (LAN ST).
DEPTH 70 mm
HEIGHT 95 mm
WIDTH 90 mm
NET WEIGHT 0.525 kg
Environment
IMMUNITY TO MICROBREAKS 10 ms
DIELECTRIC STRENGTH 1500 V for 1 minute, between I/O and earth terminals.
1500 V for 1 minute, between supply and earth terminals.
PRODUCT CERTIFICATIONS UL
CSA
MARKING CE
AMBIENT AIR TEMPERATURE FOR OPERATION 0…55 °C
AMBIENT AIR TEMPERATURE FOR STORAGE -25…70 °C
RELATIVE HUMIDITY 30…95 % without condensation.
IP DEGREE OF PROTECTION IP20
OPERATING ALTITUDE 0…2000 m
STORAGE ALTITUDE 0…3000 m
VIBRATION RESISTANCE 0.075 mm at 10…57 Hz on 35 mm symmetrical DIN rail.
1 gn at 57…150 Hz on 35 mm symmetrical DIN rail.
1.6 mm at 2…25 Hz on plate or panel with fixing kit.
4 gn at 25…100 Hz on plate or panel with fixing kit.
SHOCK RESISTANCE 15 gn for 11 ms.

The Schneider Electric Twido TWDLCAE40DRF is a programmable logic controller (PLC) from Schneider Electric’s Twido series. PLCs like the Twido TWDLCAE40DRF are used in industrial automation to control machinery and processes. Here are some key points about this PLC:

  1. Functionality: It offers a range of digital and analog inputs and outputs (I/Os) for connecting to sensors, switches, actuators, and other industrial devices.
  2. Programming: It can be programmed using Schneider Electric’s proprietary software, often through ladder logic or function block diagrams, to create logic for controlling operations.
  3. Communication: The Twido series typically supports various communication protocols, allowing integration with other automation systems and SCADA (Supervisory Control and Data Acquisition) systems.
  4. Applications: Commonly used in manufacturing, process control, and building automation, where precise control and monitoring of equipment and processes are required.
  5. Compact Design: Designed to be compact and robust, suitable for installation in industrial environments.