range | PowerLogic. |
---|---|
product name | PowerLogic PM5000. |
device short name | PM5330. |
product or component type | Power meter. |
power quality analysis | Up to the 31st harmonic. |
---|---|
device application | Power monitoring. Multi-tariff. |
type of measurement | Current. Voltage. Frequency. Power factor. Energy. Active and reactive power. |
supply voltage | 100…415 V AC 45…65 Hz. 125…250 V DC. |
network frequency | 50 Hz 60 Hz |
[In] rated current | 1 A 5 A |
type of network | 3P + N 3P 1P + N |
maximum power consumption in VA | 10 VA at 415 V |
ride-through time | 80 ms 120 V AC typical. 100 ms 230 V AC typical. 100 ms 415 V AC typical. |
display type | Backlit LCD. |
display resolution | 128 x 128 pixels. |
sampling rate | 64 samples/cycle. |
measurement current | 10…9000 mA. |
analogue input type | Voltage (impedance 5 MOhm). Current (impedance 0.3 mOhm). |
measurement voltage | 35…690 V AC 45…65 Hz between phases. 20…400 V AC 45…65 Hz between phase and neutral. |
frequency measurement range | 45…65 Hz. |
number of inputs | 2 digital |
measurement accuracy | Active energy +/- 0.5 %. Reactive energy +/- 2 %. Active power +/- 0.5 %. Apparent power +/- 0.5 %. Frequency +/- 0.05 %.. Power factor +/- 0.005. Current +/- 0.5 %. Voltage +/- 0.5 %. |
accuracy class | Class 0.5S active energy conforms to IEC 62053-22. |
number of outputs | 2 relay. 2 digital. |
information displayed | Tariff (4). |
communication port protocol | Modbus RTU and ASCII at 9.6, 19.2, and 38.4 kbauds, even/odd or none: 2 wires, insulation 2500 V. JBUS. |
communication port support | RS485. |
data recording | Maintenance logs. Time stamping. Alarm logs. Data logs. Min/max of instantaneous values. Event logs. |
memory capacity | 256 kB. |
connections – terminals | Voltage circuit: screw terminal block 4. Control circuit: screw terminal block 2. Current transformer: screw terminal block 6. Input/output circuit: screw terminal block 6. Relay output: screw terminal block 4. Ethernet network: RJ45 connector. |
mounting mode | Flush-mounted. |
mounting support | Framework. |
standards | UL 61010-1. IEC 62053-22.. IEC 61557-12. EN 50470-3.. IEC 60529. IEC 62053-24.. EN 50470-1. |
product certifications | CE conforming to IEC 61010-1. CULus conforms to UL 61010-1. |
width | 96 mm.. |
depth | 72 mm. |
height | 96 mm. |
net weight | 430 g. |
electromagnetic compatibility | Limits for harmonic current emissions in class A conforming to IEC 61000-3-2. Electrostatic discharge level 4 conforms to IEC 61000-4-2. Conducted RF disturbances at level 3, conforming to IEC 61000-4-6. Magnetic field at power frequency level 4 conforms to IEC 61000-4-8. Conducted and radiated emissions in class B, conforming to EN 55022. |
---|---|
IP degree of protection | IP52 front: conforming to IEC 60529. IP30 body: conforming to IEC 60529. |
relative humidity | 5% at 50 °C. |
pollution degree | 2 |
ambient air temperature for operation | -25…70 °C. |
ambient air temperature for storage | -40…85 °C. |
operating altitude | 2000 m. |
Unit Type of Package 1 | PCE. |
---|---|
Number of Units in Package 1 | 1 |
Package 1: Weight | 550.0 g. |
Package 1: Height | 11.0 cm. |
Package 1 width | 12.6 cm. |
Package 1 Length | 12.6 cm. |
Unit Type of Package 2 | S03. |
Number of Units in Package 2 | 12 |
Package 2 Weight | 7.6 kg. |
Package 2 Height | 30.0 cm. |
Package 2 width | 30.0 cm. |
Package 2 Length | 40.0 cm. |
Unit Type of Package 3 | P12 |
Number of Units in Package 3 | 288. |
Package 3 Weight | 206.4 kg. |
Package 3 Height | 105.0 cm. |
Package 3 width | 80.0 cm. |
Package 3 Length | 120.0 cm. |
The PowerLogic PM5330 is a high-performance power meter from Schneider Electric’s PowerLogic series. Designed for precise power monitoring and control in industrial and commercial settings, this device offers comprehensive measurement capabilities, advanced communication options, and enhanced functionality to support efficient energy management and analysis.
Key Features
Advanced Measurement Capabilities:
Voltage and Current Measurement: The PM5330 provides accurate measurement of up to four electrical parameters, including voltage, current, power, and energy. It supports multiple measurement ranges and can handle both low and high voltage applications, making it versatile for various industrial environments.
Harmonics Analysis: The meter can measure and analyze harmonic distortions up to the 63rd harmonic. This is crucial for identifying power quality issues that can affect equipment performance and lifespan.
Communication and Integration:
Communication Protocols: The PM5330 supports multiple communication protocols, including Modbus, DNP3, and Ethernet/IP. This allows for seamless integration into existing energy management systems and enables remote monitoring and control.
Web-Based Interface: It features a built-in web server that provides access to real-time data and historical trends through a standard web browser. This interface simplifies configuration, monitoring, and analysis tasks.
Data Logging and Storage:
Event Logging: The meter includes a comprehensive event logging system that records significant electrical events such as voltage sags, swells, and outages. This data is essential for troubleshooting and maintaining system reliability.
Data Storage: With ample internal storage capacity, the PM5330 can retain historical data logs, which can be retrieved for in-depth analysis and reporting. This feature is particularly useful for tracking long-term performance trends and identifying recurring issues.
User Interface:
LCD Display: The device is equipped with a high-resolution LCD display that provides clear and detailed readings of electrical parameters. Users can navigate through different measurement screens and settings easily using intuitive menu options.
Customization: The PM5330 allows users to customize display settings and configure measurement parameters according to specific needs. This flexibility enhances the user experience and ensures that the meter meets particular operational requirements.
Accuracy and reliability:
Precision: Known for its high accuracy, the PM5330 is capable of delivering precise measurements with minimal error margins. This reliability is crucial for maintaining optimal performance and ensuring compliance with industry standards.
Durability: Built to withstand harsh environmental conditions, the meter is designed with robust materials and construction to ensure longevity and reliable operation even in demanding industrial settings.
Applications:
Energy Management: The PM5330 is an essential tool for energy management systems, helping organizations monitor and optimize energy consumption. It provides valuable insights into energy usage patterns, allowing for effective energy-saving strategies and cost reduction.
Power Quality Analysis: By measuring harmonics and other power quality indicators, the PM5330 assists in identifying and addressing power quality issues that can impact equipment performance and efficiency.
System Monitoring: The meter plays a critical role in monitoring electrical systems, ensuring that they operate within safe and optimal parameters. This helps in preventing potential issues and extending the lifespan of electrical components.
Installation and Configuration:
Ease of Installation: The PM5330 is designed for straightforward installation, with clear wiring diagrams and easy-to-follow instructions. Its compact design allows for flexible mounting options in various panel configurations.
Configuration Tools: Schneider Electric provides a range of configuration tools and software to simplify the setup process. These tools facilitate parameter setting, calibration, and network integration, ensuring that the meter is optimally configured for specific applications.
Regulatory Compliance:
Standards: The PM5330 complies with relevant international standards and certifications, ensuring its suitability for use in various regions and applications. This adherence to standards helps in meeting regulatory requirements and industry best practices.
Support and documentation:
Technical Support: Schneider Electric offers comprehensive technical support for the PM5330, including troubleshooting assistance and guidance on advanced features. This support ensures that users can effectively utilize the meter and resolve any issues that may arise.
Documentation: Detailed product documentation, including user manuals and technical datasheets, is available to provide in-depth information on the meter’s features, installation, and operation. This documentation serves as a valuable resource for users seeking to maximize the meter’s functionality.