Sale!

METSEPM8244 – Power quality meter, PowerLogic PM8000

Original price was: $3,803.00.Current price is: $2,925.00.

The METSEPM8244 PowerLogic PM8000 from Schneider Electric is a high-accuracy power quality meter offering advanced features like harmonic analysis, waveform

4 in stock

Categories: , Tag:

Description

Main
rangePowerLogic.
product namePowerLogic PM8000.
device’s short namePM8244.
product or component typePower meter.
Complementary
power quality analysisEN 50160 2010 compliance report.
IEEE 519 2014 compliance report.
conforming to IEC 61000-4-30: class S power quality. measurement.
up to the 63rd harmonic.
harmonic distortion.
waveform capture.
voltage sag and swell detection.
Programmability (logic and math functions).
IEC 62586 power quality monitoring.
device applicationWAGES metering.
Power monitoring.
type of measurementCurrent.
Voltage.
Frequency.
Active and reactive power total.
Apparent power total.
Power factor total.
Active and reactive power per phase, rms.
Apparent power per phase, rms.
Power factor per phase, rms.
supply voltage90…415 V AC 45…65 Hz +/- 10 %.
110…415 V DC +/- 10 %.
network frequency50 Hz.
60 Hz.
Line-rated current10 A.
5 A.
1 A.
poles description3P
1P + N
3P + N
power consumption in VA18 VA 415 V AC.
display typeRemote LCD display.
display resolution320 x 240 pixels, QVGA.
sampling rate256 samples/cycle.
measurement current50…10000 mA.
analogue input typeVoltage (5 MOhm).
current (0.3 mOhm).
measurement voltage57…400 V AC 42…69 Hz between phase and neutral.
100…690 V AC, 42…69 Hz between phases.
frequency measurement range42…69 Hz.
number of inputs3 digital 30 V AC.
3 digital 60 V DC.
measurement accuracyCurrent +/- 0.1 %.
Voltage +/- 0.1 %.
Active energy +/- 0.2 %.
accuracy classClass 0.2S active energy IEC 62053-22.
Class 0.2 active energy ANSI C12.20.
Class 0.2 active power IEC 61557-12.
Class 0.5S reactive energy IEC 62053-24.
Class 0.5 power factor IEC 61557-12.
Class 0.2 voltage IEC 61557-12.
Class 0.2 current IEC 61557-12.
number of outputs1 pulse.
information displayedVoltage.
Current.
Frequency.
Power.
Energy consumption.
Harmonic distortion.
communication port protocolModbus RTU 115 kbauds, 2-wire.
ION 115 kbauds, 2-wire.
DNP3.
IEC 61850.
Modbus TCP/IP.
Ethernet Modbus TCP/IP Daisy Chain 10/100 Mbit/s.
RSTP 801.1d 2004.
communication port supportEthernet.
Screw terminal block RS485.
communication network typeIPv6 (internet protocol).
data recordingSequence of event recordings.
Event logs.
Min/max of instantaneous values.
Harmonics logs.
Alarm logs.
GPS synchronisation.
Waveform logs.
Data logs.
Time stamping.
Trending/forecasting.
Sag and swell logs.
memory capacity512 MB.
web servicesCustomizable home page.
File upload/download via FTP.
File upload/download via SFTP.
Web server.
Alarm notification by e-mail.
Viewing of captured waveforms (FTP).
Viewing of captured waveforms (web).
HTTPS server.
communication serviceSMTP e-mail notification.
RSTP support.
NTP time synchronization.
DHCP.
PTP time synchronization.
cybersecurityPassword protection.
Syslog protocol support.
Port hardening.
Robust security logs.
Enable/disable communication ports.
mounting modeFlush-mounted.
Clip-on.
mounting supportDIN rail meter device.
Framework remote display.
provided equipmentRemote display.
installation categoryIII
Safety ConstructionIII400…690 V conforming to IEC 61010-1:ed. 3.
III400…690 V conforming to EN 61010-1:ed. 3.
III347…600 V conforming to UL 61010-1:ed. 3.
III347…600 V conforming to CSA C22.2 No. 61010-1:ed. 3.
standardsIEC 62053-22.
IEC 62053-24.
IEC 62052-11.
IEC 61557-12.
IEEE 1588.
IEC 62586-2.
IEC 61326-1.
product certificationsCE
CULus
N998
width3.56 in (90.5 mm).
depth3.57 in (90.8 mm).
height3.56 in (90.5 mm).
net weight18.62 oz (528 g).
Environment
electromagnetic compatibilityElectrostatic discharge conforms to IEC 61000-4-2.
Radiated radio-frequency electromagnetic field. immunity test (IEC 61000-4-3).
Electrical fast transient/burst immunity test. conforming to IEC 61000-4-4.
Surge immunity test conforming to IEC 61000-4-5.
Conducted RF disturbances conforming to IEC. 61000-4-6.
Magnetic field at power frequency IEC 61000-4-8.
Voltage dips and interruptions immunity test (IEC. 61000-4-11).
Immunity to impulse waves conforms to IEC 61000-4-12.
Conducted and radiated emissions EN 55022.
Conducted and radiated emissions comply with EN 55011.
Conducted and radiated emissions (FCC Part 15).
Conducted and radiated emissions (ICES-003).
Conducted RF disturbances (2…150 Hz) CLC/TR 50579.
Surge withstand IEEE C37.90.1.
IP degree of protectionIP30, IEC 60529.
relative humidity5…95 %
ambient air temperature for operation-13…158 °F (-25…70 °C).
ambient air temperature for storage-40…185 °F (-40…85 °C).
operating altitude9842.52 ft (3000 m).
Ordering and shipping details
Category09797-PPOWERLOGIC PM8000 HARDWARE.
Discount SchedulePL1.
GTIN00785901526148.
Nbr. of units in pkg.1
Package weight(Lbs)1.4 lb (US) (0.64 kg).
ReturnabilityYes
Country of originCA.
Packing Units
Package 1: Height5.51 in (14.000 cm).
Package: 1 width5.51 in (14.000 cm).
Package 1 Length14.57 in (37.000 cm).
Offer Sustainability
Sustainable offer statusGreen premium product.
California proposition 65WARNING: Cancer and Reproductive Harm.
REACh RegulationREACh Declaration.
EU RoHS Directive
Compliant

EU RoHS Declaration.

Mercury freeYes
RoHS exemption informationYes
China’s RoHS RegulationChina RoHS declaration.
Environmental DisclosureProduct Environmental Profile.
Circularity ProfileEnd-of-life of Life Information.
WEEEThe product must be disposed on European Union markets following specific waste collection and never end up in. rubbish bins..