Range of product | Sepam series 40. Sepam series 80 NPP. Sepam series 60. Sepam series 80. |
---|---|
Device short name | ACE850TP. |
communication port protocol | ARP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX. FTP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX. HTTP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX. IEC 61850 network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX. Modbus RTU network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX. Modbus TCP/IP network: S-LAN and E-LAN.. interface: 2 Ethernet ports 10/100BASE-TX. RSTP 801.1d 2004 network: S-LAN and E-LAN. interface: 2 Ethernet ports 10/100BASE-TX.. SNMP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX. SNTP network: S-LAN and E-LAN interface: 2. Ethernet ports 10/100BASE-TX. |
---|---|
local signalling | Green LED1 for energized (front face). Green LED2 for communication status ok (front face). Green LED3 off for port 2 Ethernet 10 Mbit/s (front face). Green LED3 on for port 2 Ethernet 100 Mbit/s (front face). Green LED4 flashing. for port 2 Ethernet sending data and receiving data (front face). Green LED5 off for port 1 Ethernet 10 Mbit/s (front face). Green LED5 on for port 1 Ethernet 100 Mbit/s (front face). Green LED6 flashing for port 1 Ethernet sending data and receiving data (front face). Red LED1 flashing for not set up or not base-unit connected (front face). Red LED1 off for de-energized (front face). Red LED1 remains ON for fault (front face). |
[Us] rated supply voltage | 110…240 V AC tolerance: – 20…10 %. 24…250 V DC tolerance: – 20…10 %. |
Mounting mode | Fixed. |
Mounting support | Symmetrical DIN rail. |
Height | 127 mm. |
Width | 171 mm. |
Depth | 58 mm. |
Product weight | 0.4 kg. |
mechanical robustness | Earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3. Earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3. Jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2. Shocks de-energized (level: 2) : 30 Gn/11 ms conforming to IEC 60255-21-2. Shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2. Vibrations de-energized (level: 2) : 2 Gn, 10 Hz, 150 Hz, conforming to IEC 60255-21-1. Vibrations in operation (level: 2) : 1 Gn, 10 Hz, 150 Hz, conforming to IEC 60255-21-1. Vibrations in operation (level: Fc) : 2 Hz–13.2 Hz, a = +/- 1 mm, conforming to IEC 60068-2-6. |
maximum cable distance between devices | <100 m. |
auxiliary connection terminal | Functional earth: ring lug 1 pin(s) 1 cable(s) tinned copper braid 4 mm². Protective earth: screw-type connector 1 pin(s) 1 cable(s) wire 2.5 mm² <3 m. Supply: screw-type connector 3 pin(s) 1 cable(s) wire 0.5…2.5 mm². Supply: screw-type connector 3 pin(s) 1 cable(s) wire 1.5 mm². Supply: screw-type connector 3 pin(s) 1 cable(s) wire 2.5 mm² Supply: screw-type conne.ctor 3 pin(s) 2 cable(s) wire 0.5…1 mm². Supply: screw-type connector 3 pin(s) 2 cable(s) wire 1 mm². Supply: screw-type connector 4 pin(s) 1 cable(s) wire 0.5…2.5 mm². Supply: screw-type connector 4 pin(s) 1 cable(s) wire 1.5 mm². Supply: screw-type connector 4 pin(s) 1 cable(s) wire 2.5 mm². Supply: screw-type connector 4 pin(s) 2 cable(s) wire 0.5…1 mm². Supply: screw-type connector 4 pin(s) 2 cable(s) wire 1 mm². |
wire stripping length | Supply: 8 mm. |
electromagnetic compatibility | 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC and MD, conforming to ANSI C37.90.1. 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), III, 2.5 kV MC, 1 kV MD, conforming to IEC 60255-22-1. 100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC, 1 kV MD, conforming to IEC 61000-4-12. Conducted disturbance emission: (emission tests), conforming to IEC 60255-25. Conducted disturbance emission: (emission tests), B, conforming to EN 55022. Disturbing field emission: (emission tests), conforming to IEC 60255-25. Disturbing field emission: (emission tests), A, conforming to EN 55022. Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3. Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2. Fast transient bursts: (immunity tests-conducted. disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1 Fast transient bursts: (immunity tests-conducted. disturbances), A or B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4. Fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4. Immunity to conducted RF disturbances: (immunity tests-conducted disturbances), 10 V, conforming to IEC 60255-22-6. Immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m. (continuous)-300 A/m (13 s), conforming to IEC 61000-4-8 Immunity to radiated fields: (immunity tests-radiated. disturbances), 10 V/m, 80 MHz…1 GHz, conforming to IEC 60255-22-3. Immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz…1 GHz, conforming to ANSI C37.90.2 (1995). Immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz…2 GHz, conforming to IEC 61000-4-3. Surges: (immunity tests-conduct.ed disturbances), III, 2 kV MC, 1 kV MD, conforming to IEC 61000-4-5. Voltage interruptions: (immunity tests-conducted. disturbances), 100 %, 10 ms, conforming to IEC 60255-11. |
---|---|
climatic withstand | Influence of corrosion/gaz test 4 (in operation) : 21 days, 75. % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.02 ppm NO2, 0.01 ppm Cl2 conforming to IEC 60068-2-60 Continuous exposure to damp heat (in operation): Ca: 10 days, 93% RH, 40 °C (104 °F), conforming to IEC 60068-2-3. Continuous exposure to damp heat (in storage): Ca: 56 days, 93% RH, 40 °C (104 °F), conforming to IEC 60068-2-3. Exposure to cold (in operation): Ab: -25 °C (-13 °F) conforming to IEC 60068-2-1. Exposure to cold (in storage): Ab: -25 °C (-13 °F) conforming to IEC 60068-2-1. Exposure to dry heat (in operation): Bb: 70 °C (158 °F) conforming to IEC 60068-2-2. Exposure to dry heat (in storage) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2. Influence of corrosion/gaz test 2 (in operation) : C: 21 days, 75 % RH, 25 °C (- 13 °F), 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60. Salt mist (in operation) : Kb/2 conforming to IEC 60068-2-52. Temperature variation with specified variation rate (in operation) : Nb: – 25 °C to 70 °C (- 13 °F to 158 °F) 5. °C/min (41 °F/min) conforming to IEC 60068-2-14. |
Ambient air temperature for operation | -25…70 °C. |
Unit Type of Package 1 | PCE. |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 9.800 cm. |
Package 1 Width | 16.700 cm. |
Package 1 Length | 19.800 cm. |
Package 1 Weight | 721 g |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 6 |
Package 2 Height | 30.000 cm. |
Package 2 Width | 30.000 cm. |
Package 2 Length | 40.000 cm. |
Package 2 Weight | 4.733 kg. |
Unit Type of Package 3 | P12 |
Number of Units in Package 3 | 48 |
Package 3 Height | 44.500 cm. |
Package 3 Width | 80.000 cm. |
Package 3 Length | 120.000 cm. |
Package 3 Weight | 49.784 kg. |
Introduction
The 59658 is a specialized Ethernet interface designed for industrial and commercial networking applications. It features two Ethernet ports operating at 10/100BASE-TX speeds, providing reliable and efficient network connectivity. This interface is crucial for integrating devices into a network, ensuring seamless communication and data exchange in various operational environments.
Design and Architecture
The 59658 Ethernet interface is built with a focus on robustness and flexibility, catering to the needs of diverse networking applications. Here’s a detailed look at its design and architecture:
- Ports: The 59658 is equipped with two Ethernet ports, each supporting 10/100BASE-TX communication. These ports offer flexibility in network configurations, allowing for direct connections to network switches, routers, or other networked devices. The dual-port design enhances network redundancy and reliability by enabling multiple connection options.
- Speed and Standards: The interface supports both 10 Mbps and 100 Mbps speeds, accommodating various networking needs. The 10/100BASE-TX standard ensures compatibility with a wide range of Ethernet equipment and provides reliable data transfer rates for most industrial and commercial applications.
- Connector Type: The Ethernet ports use standard RJ45 connectors, which are commonly found in Ethernet networking. This ensures compatibility with a broad range of network cables and devices, simplifying installation and integration.
Performance and Features
The 59658 Ethernet interface offers several key features and performance attributes:
- Data Transfer Rate: Supporting both 10 Mbps and 100 Mbps speeds, the 59658 ensures efficient data transfer across the network. This range of speeds allows for adaptable performance depending on the specific requirements of the networked devices and applications.
- Compatibility: The interface adheres to the 10/100BASE-TX standard, making it compatible with various Ethernet devices and network configurations. This compatibility ensures seamless integration with existing network infrastructure and devices.
- Network Redundancy: With two Ethernet ports, the 59658 provides options for network redundancy and failover. This dual-port setup can be configured for network redundancy, enhancing the reliability of network connections by providing alternative pathways in case of a failure.
- Industrial Suitability: Designed for industrial environments, the 59658 interface is built to withstand harsh conditions such as temperature fluctuations, vibrations, and electromagnetic interference. Its robust design ensures reliable operation in challenging environments.
- Ease of Installation: The interface features user-friendly RJ45 connectors and straightforward configuration, making installation and setup quick and efficient. The simplicity of the design facilitates integration into existing network setups without the need for specialized tools or extensive configuration.
Applications
The 59658 Ethernet interface is versatile and suitable for a variety of applications:
- Industrial Automation: In industrial settings, the 59658 is used to connect automation devices such as PLCs, sensors, and HMIs to the network. Its reliable performance and dual-port design make it ideal for ensuring continuous communication in automated processes.
- Building Management Systems: The interface can be employed in building management systems to connect various building automation components, such as HVAC systems, lighting controls, and security devices. Its compatibility with standard Ethernet equipment ensures seamless integration.
- Commercial Networking: In commercial environments, the 59658 can be used to connect office equipment, such as computers, printers, and networked peripherals, to the corporate network. Its flexibility and ease of installation make it suitable for diverse networking needs.
- Data Acquisition Systems: The interface is also applicable in data acquisition systems, where it facilitates the collection and transmission of data from sensors and measurement devices to a central data repository. The dual-port feature supports redundant connections to ensure reliable data transfer.
Advantages
- Dual Ports: The inclusion of two Ethernet ports enhances network flexibility and redundancy, providing options for failover and load balancing.
- High Compatibility: Adhering to the 10/100BASE-TX standard, the interface integrates seamlessly with a wide range of Ethernet devices and network configurations.
- Industrial-Grade Design: Built to withstand harsh industrial conditions, the 59658 ensures reliable operation and durability in challenging environments.
- Easy Installation: Standard RJ45 connectors and straightforward configuration make installation and setup simple and efficient.
Installation and Maintenance
- Installation: The 59658 Ethernet interface is designed for easy installation. It can be mounted in standard networking enclosures or integrated into existing network setups. The RJ45 connectors allow for quick and straightforward connections to network cables.
- Maintenance: Routine maintenance involves checking the integrity of network connections and ensuring that the interface is functioning correctly. Regular monitoring and testing of network performance help identify and address any potential issues. The interface’s robust design minimizes the need for frequent maintenance.
Conclusion
The 59658 Ethernet interface with two 10/100BASE-TX ports is a versatile and reliable solution for network connectivity in industrial and commercial applications. Its dual-port design provides flexibility and redundancy, while its adherence to standard Ethernet protocols ensures compatibility with a wide range of devices. With its industrial-grade construction and ease of installation, the 59658 is well-suited for applications requiring robust and efficient network performance.