Main
range of product Preventa Safety automation.
product or component type Configurable safety controller.
safety module name XPSMC.
safety use category Category 4 maximum conforming to EN 954-1/EN/ISO. 13849-1.
PLE maximum conforming to EN/ISO 13849-1.
SIL 3 maximum conforming to IEC 61508.
type of start Configurable.
standards EN/IEC 60947-5-1.
EN 574/ISO 13851.
EN 1760-1/ISO 13856-1.
EN/IEC 61496-1.
IEC 61508.
EN 954-1/EN/ISO 13849-1.
EN/IEC 60204-1
product certifications UL
TÜV
CSA
[Us] rated supply voltage 24 V DC – 20…20 %.
number of inputs 32
communication port protocol CANopen with 1 SUB-D 9-pin male port(s), serial link,. transmission rate: 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps or 1 Mbps.
Modbus with 1 RJ45 port(s), serial link, transmission rate: 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps.
safety level Can reach PL e/category 4 conforming to EN 954-1/EN/ISO 13849-1.
Can reach SIL 3 conforming to IEC 61508.
Complementary
function of module Dynamic monitoring of hydraulic valves on linear presses.
Eccentric press.
Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring.
Enabling switch monitoring, 2 or 3 contacts
Foot switch monitoring.
Guard monitoring for injection presses and blowing machines.
Guard monitoring with 1 or 2 limit switches
Hydraulic press.
Magnetic switch monitoring.
Monitoring safety stop at top dead centre on eccentric press.
Muting function of light curtains.
Position selector.
Safety mat monitoring.
Safety time delays.
Shaft/chain breaking monitor.
Zero speed detection.
Light curtain monitoring category 4 conforming to EN/IEC 61496.
Two-hand control category 3 conforming to EN. 574/ISO 13851.
synchronisation time between inputs Depending on configuration selected.
power consumption in W 12 W
input protection type External fuse 16 A.
[Uc] control circuit voltage 28.8 V
maximum line resistance 100 Ohm <2000 m.
output type 2 relays, 2 NO contacts (4 NO total) circuit(s).
Solid state, 6 circuit(s), volt-free.
breaking capacity 180 VA holding AC-15 C300 relay output.
1800 VA inrush AC-15 C300 relay output.
breaking capacity 2 A at 24 V for static output circuit.
1.5 A at 24 V (DC-13) time constant: 50 ms for relay output.
output thermal current 4 A for both outputs simultaneously.
6 A for 1 output and 2 A for the other for relay. output.
[Ith] conventional free air thermal current 16 A for relay output.
6.5 A for static output circuit.
associated fuse rating 16 A gL for power supply.
4 A gL for relay output.
6 A fast blow for relay output.
minimum output current 10 mA for relay output.
minimum output voltage 17 V for relay output.
response time Configurable : 20 ms or 30 ms with software XPSMCWIN.
[Ui] rated insulation voltage 300 V (pollution degree 2) conforming to IEC 60647-5-1, DIN VDE 0110 part 1.
[Uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to IEC 60647-5-1, DIN VDE 0110 part 1.
method of access Slave.
exchange size 14 words.
number of addresses 1…127 for CANopen.
1…247 for Modbus.
parity Even for Modbus.
No for Modbus.
Odd for Modbus.
data format 1 start bit/8 data bits.
1 stop bit even or odd.
2 stop bits without parity.
RTU (Remote Terminal Unit) mode.
supported modbus function 01: 8-bit output data/32-bit input data.
02: 32-bit input data/8-bit output data.
03: information and errors.
local signalling 48 LEDs
mounting support Mounting plate.
depth 153 mm.
height 151.5 mm.
width 74 mm.
net weight 0.84 kg.
Environment
IP degree of protection IP20 conforming to EN/IEC 60529.
ambient air temperature for operation -10…55 °C.
ambient air temperature for storage -25…85 °C.
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.4 cm.
Package 1 Width 17.8 cm.
Package 1 Length 25.8 cm.
Package 1 Weight 1.28 kg.
Unit Type of Package 2 S04
Number of Units in Package 2 6
Package 2 Height 30.0 cm.
Package 2 Width 40.0 cm.
Package 2 Length 60.0 cm.