LC1D09U7 Motor control
Original price was: $19.00.$15.00Current price is: $15.00.
9 in stock
Free shipping on orders over $5000!
- Satisfaction Guaranteed
- No Hassle Refunds
- Secure Payments
Description
Description
RANGE OF PRODUCT | TeSys Deca |
---|---|
PRODUCT OR COMPONENT TYPE | Contactor |
DEVICE SHORT NAME | LC1D |
CONTACTOR APPLICATION | Motor control. Resistive load. |
UTILISATION CATEGORY | AC-3. AC-4. AC-1. AC-3e. |
POLES DESCRIPTION | 3P |
[UE] RATED OPERATIONAL VOLTAGE | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC. |
[IE] RATED OPERATIONAL CURRENT | 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit. 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit. 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit. |
[UC] CONTROL CIRCUIT VOLTAGE | 240 V AC, 50/60 Hz. |
MOTOR POWER KW | 2.2 kW at 220…230 V AC 50/60 Hz (AC-3). 4 kW at 380…400 V AC 50/60 Hz (AC-3). 4 kW at 415…440 V AC 50/60 Hz (AC-3). 5.5 kW at 500 V AC 50/60 Hz (AC-3). 5.5 kW at 660…690 V AC 50/60 Hz (AC-3). 2.2 kW at 400 V AC 50/60 Hz (AC-4). 2.2 kW at 220…230 V AC 50/60 Hz (AC-3e). 4 kW at 380…400 V AC 50/60 Hz (AC-3e). 4 kW at 415…440 V AC 50/60 Hz (AC-3e). 5.5 kW at 500 V AC 50/60 Hz (AC-3e). 5.5 kW at 660…690 V AC 50/60 Hz (AC-3e). |
---|---|
MOTOR POWER HP | 1 hp at 230/240 V AC 50/60 Hz for 1-phase motors. 2 hp at 200/208 V AC 50/60 Hz for 3-phase motors. 2 hp at 230/240 V AC 50/60 Hz for 3-phase motors. 5 hp at 460/480 V AC 50/60 Hz for 3-phase motors. 7.5 hp at 575/600 V AC 50/60 Hz for 3-phase motors. 0.33 hp at 115 V AC 50/60 Hz for 1-phase motors. |
COMPATIBILITY CODE | LC1D. |
POLE CONTACT COMPOSITION | 3 NO. |
CONTACT COMPATIBILITY | M2 |
PROTECTIVE COVER | With |
[ITH] CONVENTIONAL FREE AIR THERMAL CURRENT | 25 A (at 60 °C) for power circuit. 10 A (at 60 °C) for the signaling circuit. |
IRMS RATED MAKING CAPACITY | 250 A at 440 V for power circuit conforming to IEC 60947. 140 A AC for signalling circuit conforming to IEC 60947-5-1. 250 A DC for the signaling circuit conforming to IEC 60947-5-1. |
RATED BREAKING CAPACITY | 250 A at 440 V for power circuit conforming to IEC 60947. |
[ICW] RATED SHORT-TIME WITHSTAND CURRENT | 105 A 40 °C, 10 s for power circuit. 210 A 40 °C, 1 s for power circuit. 30 A 40 °C, 10 min for power circuit. 61 A 40 °C, 1 min for power circuit. 100 A – 1 s for signalling circuit. 120 A – 500 ms for the signaling circuit. 140 A to 100 ms for the signaling circuit. |
ASSOCIATED FUSE RATING | 10 A gG for the signaling circuit conforming to IEC 60947-5-1. 25 A gG at <= 690 V coordination type 1 for power circuit. 20 A gG at <= 690 V coordination type 2 for power circuit. |
AVERAGE IMPEDANCE | 2.5 mOhm (25 A, 50 Hz) for power circuit. |
POWER DISSIPATION PER POLE | 1.56 W AC-1. 0.2 W AC-3. 0.2 W AC-3e. |
[UI] RATED INSULATION VOLTAGE | Power circuit: 690 V, conforming to IEC 60947-4-1. Power circuit: 600 V, CSA-certified. Power circuit: 600 V, UL certified. Signaling circuit: 690 V, conforming to IEC 60947-1. Signaling circuit: 600 V CSA-certified. Signaling circuit: 600 V UL certified |
OVERVOLTAGE CATEGORY | III |
POLLUTION DEGREE | 3 |
[UIMP] RATED IMPULSE WITHSTAND VOLTAGE | 6 kV, conforming to IEC 60947 |
SAFETY RELIABILITY LEVEL | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1. B10d = 20000000 cycles contactor with, mechanical load conforming to EN/ISO 13849-1. |
MECHANICAL DURABILITY | 15 Mcycles. |
ELECTRICAL DURABILITY | 0.6 Mcycles 25 A AC-1 at Ue <= 440 V. 2 Mcycles 9 A AC-3 at Ue <= 440 V. 2 Mcycles 9 A AC-3e at Ue <= 440 V. |
CONTROL CIRCUIT TYPE | AC at 50/60 Hz. |
COIL TECHNOLOGY | Without built-in suppressor module. |
CONTROL CIRCUIT VOLTAGE LIMITS | 0.3…0.6 Uc (-40…70 °C): drop-out AC 50/60 Hz. 0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz. 0.85…1.1 Uc (-40…60 °C): operational AC 60 Hz. 1…1.1 Uc (60…70 °C): operational AC 50/60 Hz. |
INRUSH POWER IN VA | 70 VA 60 Hz, cos phi 0.75 (at 20 °C). 70 VA 50 Hz, cos phi 0.75 (at 20 °C). |
HOLD-IN POWER CONSUMPTION IN VA | 7.5 VA 60 Hz, cos phi 0.3 (at 20 °C). 7 VA 50 Hz, cos phi 0.3 (at 20 °C). |
HEAT DISSIPATION | 2…3 W at 50/60 Hz. |
OPERATING TIME | 12…22 ms closing. 4…19 ms opening. |
MAXIMUM OPERATING RATE | 3600 cyc/h, 60 °C. |
CONNECTIONS AND TERMINALS | Power circuit: screw clamp terminals 1 1/4 mm²; cable stiffness: flexible without cable end. Power circuit: screw clamp terminals 2 1/4 mm²; cable stiffness: flexible without cable end. Power circuit: screw clamp terminals 1 1/4 mm²; cable stiffness: flexible with cable end. Power circuit: screw clamp terminals 2 1…2.5 mm²; cable stiffness: flexible with cable end. Power circuit: screw clamp terminals 1 1/4 mm²; cable stiffness: solid without cable end. Power circuit: screw clamp terminals 2 1/4 mm²; cable stiffness: solid without cable end. Control circuit: screw clamp terminals 1 1/4. mm²; cable stiffness: flexible without cable end. Control circuit: screw clamp terminals 2 1/4. mm²; cable stiffness: flexible without cable end. Control circuit: screw clamp terminals 1 1/4. mm²; cable stiffness: flexible with cable end. Control circuit: screw clamp terminals 2 1…2.5. mm²; cable stiffness: flexible with cable end. Control circuit: screw clamp terminals 1 1/4. mm²; cable stiffness: solid without cable end. Control circuit: screw clamp terminals 2 1/4. mm²; cable stiffness: solid without cable end. |
TIGHTENING TORQUE | Power circuit: 1.7 N.m. on screw clamp. terminals with screwdriver flat Ø 6 mm. Power circuit: 1.7 N.m. on screw clamp. terminals with screwdriver Philips No. 2. Control circuit: 1.7 N.m. on screw clamp. terminals with screwdriver flat Ø 6 mm. Control circuit: 1.7 N.m. on screw clamp. terminals with screwdriver Philips No. 2. Control circuit: 1.7 N.m. on screw clamp. terminals, with screwdriver pozidriv No. 2. Power circuit: 1.7 N.m. on screw clamp. terminals, with screwdriver pozidriv No. 2. |
AUXILIARY CONTACT COMPOSITION | 1 NO + 1 NC |
AUXILIARY CONTACTS TYPE | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1. type mirror contact 1 NC conforming to IEC 60947-4-1. |
SIGNALLING CIRCUIT FREQUENCY | 25…400 Hz. |
MINIMUM SWITCHING VOLTAGE | 17 V for the signaling circuit. |
MINIMUM SWITCHING CURRENT | 5 mA for the signaling circuit. |
INSULATION RESISTANCE | > 10 MOhm for signalling circuit. |
NON-OVERLAP TIME | 1.5 ms on de-energisation between NC and NO contact. 1.5 ms on energization between NC and NO contact. |
MOUNTING SUPPORT | Rail Plate |
STANDARDS | CSA C22.2 No. 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
---|---|
PRODUCT CERTIFICATIONS | BV UL GOST CSA. RINA GL LROS (Lloyds register of shipping). CCC. DNV UKCA |
IP DEGREE OF PROTECTION | IP20 front face conforming to IEC 60529. |
PROTECTIVE TREATMENT | TH conforming to IEC 60068-2-30. |
CLIMATIC WITHSTAND | Conforming to IACS E10 exposure to damp heat. conforming to IEC 60947-1 Annex Q. category D exposure to damp heat. |
PERMISSIBLE AMBIENT AIR TEMPERATURE AROUND THE DEVICE | -40…60 °C. 60…70 °C with derating. |
OPERATING ALTITUDE | 0…3000 m. |
FIRE RESISTANCE | 850 °C, conforming to IEC 60695-2-1. |
FLAME RETARDANCE | V1 conforming to UL 94. |
MECHANICAL ROBUSTNESS | Vibrations contactor open (2 Gn, 5… 300 Hz). Vibrations contactor closed (4 Gn, 5… 300 Hz). Shocks contactor open (10 Gn for 11 ms). Shocks contactor closed (15 Gn for 11 ms). |
HEIGHT | 77 mm |
WIDTH | 45 mm |
DEPTH | 86 mm |
NET WEIGHT | 0.32 kg |
UNIT TYPE OF PACKAGE 1 | PCE |
---|---|
NUMBER OF UNITS IN PACKAGE 1 | 1 |
PACKAGE 1 HEIGHT | 5.0 cm |
PACKAGE 1 WIDTH | 9.2 cm |
PACKAGE 1 LENGTH | 11.2 cm |
PACKAGE 1 WEIGHT | 352.0 g |
UNIT TYPE OF PACKAGE 2 | S02 |
NUMBER OF UNITS IN PACKAGE 2 | 20 |
PACKAGE 2 HEIGHT | 15.0 cm |
PACKAGE 2 WIDTH | 30.0 cm |
PACKAGE 2 LENGTH | 40.0 cm |
PACKAGE 2 WEIGHT | 7.426 kg |
UNIT TYPE OF PACKAGE 3 | P06 |
NUMBER OF UNITS IN PACKAGE 3 | 320 |
PACKAGE 3 HEIGHT | 77.0 cm |
PACKAGE 3 WIDTH | 80.0 cm |
PACKAGE 3 LENGTH | 60.0 cm |
PACKAGE 3 WEIGHT | 127.316 kg |
Contact