Main
Range of product Altistart 48.
Product or component type Soft starter.
Product destination Asynchronous motors.
Product specific application Heavy duty industry and pumps.
device short name ATS48.
Utilisation category AC-53A.
Ue power supply voltage 208…690 V – 15…10 %.
power supply frequency 50…60 Hz – 5…5 %.
Motor power kW 11 kW at 400 V for standard applications.
11 kW at 440 V for standard applications.
11 kW at 500 V for standard applications.
11 kW at 525 V for standard applications
11 kW at 660 V for severe applications.
15 kW at 660 V for standard applications.
15 kW at 690 V for severe applications.
4 kW at 230 V for severe applications.
9 kW at 500 V for severe applications.
9 kW at 525 V for severe applications.
7.5 kW at 400 V for severe applications.
7.5 kW at 440 V for severe applications.
18.5 kW at 690 V for standard applications.
5.5 kW at 230 V for standard applications.
Motor power hp 10 hp at 460 V for severe applications.
15 hp at 460 V for standard applications.
15 hp at 575 V for severe applications.
20 hp at 575 V for standard applications.
3 hp at 208 V for severe applications.
5 hp at 208 V for standard applications.
5 hp at 230 V for severe applications.
7.5 hp at 230 V for standard applications
Complementary
device connection In the motor supply line.
Protection type Phase failure: line.
Thermal protection: motor.
Thermal protection: starter.
Standards EN/IEC 60947-4-2.
product certifications CSA
SEPRO.
UL
GOST
NOM 117
TCF
CCC
C-Tick
DNV
Marking CE
Discrete input number 5
Discrete input type PTC, 750 Ohm at 25 °C.
(Stop, Run, LI3, LI4) logic, <= 8 mA, 4300 Ohm.
Discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA.
Minimum switching current 10 mA at 6 V DC for relay outputs.
Discrete output number 2
Discrete output type (LO1) logic output 0 V is common configurable.
(LO2) logic output 0 V is common configurable.
(R1) relay outputs fault relay NO.
(R2) relay outputs the end of starting relay NO.
(R3) relay outputs motor-powered NO.
Analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm.
communication port protocol Modbus
connector type 1 RJ45
Communication data link Serial
Physical interface RS485 multidrop.
Transmission rate 4800, 9600, or 19200 bps.
function available External bypass (optional).
Operating position Vertical +/- 10 degree
Height 275 mm
Width 160 mm
Depth 190 mm
Net weight 4.9 kg
Environment
Electromagnetic compatibility Conducted and radiated emissions at level A, conforming to IEC 60947-4-2.
Conducted and radiated emissions at level B, conforming to IEC 60947-4-2.
Damped oscillating waves level 3 conforms to IEC 61000-4-12.
Electrostatic discharge level 3 conforms to IEC 61000-4-2.
Immunity to electrical transients, level 4, conforms to IEC 61000-4-4.
Immunity to radiated radio-electrical interference level 3 conforms to IEC 61000-4-3.
Voltage/current impulse level 3 conforms to IEC 61000-4-5.
Relative humidity 0…95 % without condensation or dripping water, conforming to EN/IEC 60068-2-3.
Ambient air temperature for operation 40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating).
Ambient air temperature for storage -25…70 °C.
Operating altitude <= 1000 m without derating.
> 1000–2000 m with current derating of 2.2 % per additional 100 m.
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 29 cm
Package 1 Width 26 cm
Package 1 Length 37 cm
Package 1 Weight 6.053 kg
Unit Type of Package 2 P06
Number of Units in Package 2 8
Package 2 Height 73.5 cm
Package 2 Width 80 cm
Package 2 Length 60 cm
Package 2 Weight 61.424 kg

The ATS48D22Y soft starter by Schneider Electric is a sophisticated motor control device designed to manage the starting and stopping of three-phase asynchronous motors in industrial applications. Here’s an in-depth look at its features, capabilities, applications, and benefits:

Overview of ATS48D22Y Soft Starter

The ATS48D22Y is part of Schneider Electric’s ATS48 series, known for its reliability and advanced motor control functionalities. It provides precise control over motor acceleration and deceleration, offering a smooth transition from start to full speed while reducing electrical and mechanical stress on the motor and connected equipment.

Key Features and Capabilities

1. Soft Start and Stop Functionality: The soft starter ensures gradual acceleration and deceleration of the motor, minimizing sudden voltage surges and mechanical shocks. This feature is crucial for extending the lifespan of equipment and improving operational efficiency.

2. Integrated Protection Mechanisms: It includes comprehensive protections such as thermal overload, short-circuit, and phase loss protections. These safeguards prevent damage to the motor and ensure reliable operation even in challenging industrial environments.

3. User-Friendly Interface: Equipped with an intuitive interface, typically featuring a keypad or digital display, the ATS48D22Y allows for easy programming, parameter adjustment, and real-time monitoring. This simplifies setup and maintenance tasks for operators and maintenance personnel.

4. Compact and Robust Design: Designed for space-saving installations, the ATS48D22Y combines a compact footprint with robust construction, suitable for diverse industrial settings. It integrates seamlessly into existing control systems, offering flexibility and reliability.

5. Communication Capabilities: Some models support communication protocols such as Modbus or Ethernet, enabling integration with broader automation systems. This facilitates remote monitoring, diagnostics, and data logging, enhancing operational transparency and efficiency.

6. Energy Efficiency Features: The soft starter optimizes energy consumption by controlling motor speed during startup and operation, reducing peak demand and overall power consumption. This feature aligns with sustainability goals and helps lower operational costs.

Applications

The ATS48D22Y soft starter is widely used across various industrial sectors, including:

  • Water and Wastewater Treatment: Controls pumps and compressors to manage flow rates and pressure, ensuring efficient operation and minimal downtime.
  • Manufacturing and Processing: Enhances the reliability of conveyor belts, mixers, and agitators by reducing mechanical stress and ensuring smooth operation during startup and shutdown.
  • HVAC Systems: Optimizes the performance of fans and blowers, maintaining temperature and air quality control in commercial and industrial buildings.
  • Mining and Quarrying: Facilitates controlled acceleration of crushers and conveyors, minimizing wear and tear while improving productivity in harsh mining environments.

Installation and Maintenance

Installation of the ATS48D22Y should be performed by qualified technicians following manufacturer guidelines and local electrical codes. Routine maintenance includes inspecting for dust accumulation, verifying connections, and ensuring adequate ventilation to maintain optimal performance and reliability.

Conclusion

In conclusion, the ATS48D22Y soft starter from Schneider Electric offers robust motor control capabilities suitable for a wide range of industrial applications. With its advanced features, including soft start and stop functionality, integrated protections, and user-friendly interface, it enhances operational efficiency, reduces maintenance costs, and extends the lifespan of three-phase asynchronous motors. Whether deployed in manufacturing plants, water treatment facilities, or mining operations, the ATS48D22Y continues to demonstrate its value in improving reliability, efficiency, and sustainability across diverse industrial sectors.