Description

Main
range of product Modicon Premium Automation Platform.
product or component type Analog output module.
analogue output number 8
analogue output type Current: 0…20 mA.
Current: 4…20 mA.
Voltage: +/- 10 V.
analog/digital conversion 13 bits + sign +/- 10 V.
13 bits, 0.20 mA.
13 bits, 4…20 mA.
Complementary
conversion time 5 ms
measurement resolution 1.28 mV +/- 10 V.
2.56 µA 0…20 mA.
2.56 µA, 4…20 mA.
electrical connection 1 SUB-D 25 connector.
measurement error 0.14 % of full scale +/- 10 V, 25 °C.
0.21 % of full scale = 0.20 mA, 25 °C.
0.21 % of full scale 4…20 mA, 25 °C.
0.28 % of full scale +/- 10 V = 0.60 °C.
0.52% of full scale, 0…20 mA, 0…60 °C.
0.52% of full scale, 4.20 mA, 0.60 °C.
isolation between channels Common point.
isolation between channels and bus 1000 Vrms.
isolation between channels and ground 1000 Vrms.
protection type Short-circuit protection.
Overload protection.
output voltage limits <= 30 V
load impedance ohmic < 600 Ohm = 0.20 mA.
< 600 Ohm 4…20 mA.
> 1000 Ohm +/- 10 V.
maximum load inductance 300 µH.
maximum load capacitance 0.1 µF.
marking CE.
current consumption 200 mA at 5 V DC.
300 mA at 24 V DC.
module format Standard
terminals description: PLC n°1 (16)OUT_ANA_CUR#1.
(13)IN_ANA_STD#.
(24)OUT_ANA_VOLT#7.
(8)OUT_ANA_CUR#4.
(20)OUT_ANA_COM#4.
(1)OUT_ANA_VOLT#0.
(17)OUT_ANA_COM#2.
(4)OUT_ANA_VOLT#2.
(9)OUT_ANA_COM#5.
(11)OUT_ANA_CUR#6.
(19)OUT_ANA_CUR#3.
PW_NEG#.
(25)OUT_ANA_CUR#7.
(3)OUT_ANA_COM#1.
(12)OUT_ANA_COM#7.
(5)OUT_ANA_CUR#2.
(6)OUT_ANA_COM#3.
(15)OUT_ANA_VOLT#1.
(18)OUT_ANA_VOLT#3.
(22)OUT_ANA_CUR#5.
(10)OUT_ANA_VOLT#6.
PW_POS#.
(14)OUT_ANA_COM#0.
(23)OUT_ANA_COM#6.
(2)OUT_ANA_CUR#0.
(7)OUT_ANA_VOLT#4.
(21)OUT_ANA_VOLT#5.
Environment
standards 93/68/EEC.
CSA C22.2 No. 213 Class I Division 2 Group A.
CSA C22.2 No. 142.
73/23/EEC.
CSA C22.2 No. 213 Class I Division 2 Group B.
89/336/EEC.
CSA C22.2 No. 213, Class I, Division 2, Group D.
UL 508.
IEC 61131-2.
92/31/EEC.
CSA C22.2 No. 213 Class I Division 2 Group C.
product certifications BV
RINA
DNV
LR
ABS
RMRS
GL
ambient air temperature for operation 0…60 °C
ambient air temperature for storage -25…70 °C
relative humidity 10…95% without condensation for operation.
5… 95%% without condensation for storage.
operating altitude 0…2000 m
protective treatment TC
IP degree of protection IP20
pollution degree 2
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1: Weight 465 g
Package 1: Height 5.5 cm
Package: 1 width 18 cm
Package 1 Length 26 cm
Unit Type of Package 2 S04
Number of Units in Package 2 12
Package 2: Weight 6.527 kg
Package 2: Height 30 cm
Package 2 width 40 cm
Package 2 Length 60 cm

The TSXASY800 is an analog output module designed for the Modicon Premium range of programmable logic controllers (PLCs) by Schneider Electric. This module plays a crucial role in industrial automation systems, providing precise analog signal outputs to control various processes and equipment. This comprehensive guide covers the features, applications, installation, and benefits of the TSXASY800, offering a detailed understanding of its capabilities and functions.

Features of the TSXASY800 Analog Output Module

  1. Analog Output Channels: The TSXASY800 features multiple analog output channels, typically providing up to 8 channels. This allows for the simultaneous control of multiple analog devices or processes, making it versatile for complex automation tasks.
  2. Output Range: The module supports a wide output range, including current (4–20 mA) and voltage (0–10 V) signals. This flexibility ensures compatibility with a variety of field devices and control systems.
  3. Resolution and Accuracy: The TSXASY800 offers high resolution and accuracy in its analog outputs. This precision is essential for applications requiring exact control and monitoring, such as in process industries or sophisticated control systems.
  4. Isolation: Each output channel on the TSXASY800 is electrically isolated, which helps to prevent interference and protect the module from voltage spikes or other electrical disturbances. This isolation contributes to the module’s reliability and durability.
  5. Diagnostics and Monitoring: The module includes diagnostic features that allow for real-time monitoring of output values and status. This capability helps in identifying and troubleshooting issues quickly, ensuring smooth operation of the automation system.
  6. Compatibility: The TSXASY800 is designed to integrate seamlessly with Modicon Premium PLCs. It connects directly to the PLC backplane, providing a straightforward and reliable interface for analog output control.
  7. Calibration and Configuration: The module supports calibration and configuration options to tailor its performance to specific application needs. This includes adjusting output ranges and linearity to match the requirements of connected devices.

Applications of the TSXASY800 Analog Output Module

  1. Industrial Process Control: In manufacturing and process industries, the TSXASY800 is used to control various processes such as temperature, pressure, flow, and level. It sends analog signals to actuators, valves, and other devices, enabling precise control and automation.
  2. Environmental Monitoring: The module is employed in environmental monitoring systems to control and adjust parameters like air quality, water quality, and other environmental factors. Its accurate analog outputs help maintain optimal conditions and compliance with regulations.
  3. Building Management Systems: In commercial and industrial buildings, the TSXASY800 is used in building management systems to control HVAC systems, lighting, and other infrastructure components. It allows for fine-tuned adjustments based on real-time data, enhancing energy efficiency and occupant comfort.
  4. Utilities and Infrastructure: The module is utilized in utilities and infrastructure applications, such as water treatment plants, power generation facilities, and transportation systems. It provides reliable analog outputs for controlling equipment and managing operational processes.
  5. Laboratory and Research Applications: In laboratory settings, the TSXASY800 provides precise analog signals for experimental setups and control systems. Its high resolution and accuracy are essential for conducting accurate and reliable research.

Installation and Configuration

  1. Preparation: Before installation, ensure you have the necessary tools and equipment, including wiring for analog signals, and verify that the TSXASY800 module is compatible with your Modicon Premium PLC and existing system.
  2. Physical Installation: Insert the TSXASY800 module into an available slot on the Modicon Premium PLC rack. Secure the module using the appropriate mounting hardware. Ensure that the PLC is powered off during installation to prevent damage.
  3. Wiring: Connect the analog output wiring to the terminals on the TSXASY800 module. Follow the wiring diagram provided in the module’s documentation to ensure correct connections for current or voltage outputs.
  4. Configuration: Access the module’s configuration settings through the PLC’s programming software. Configure output ranges, calibration parameters, and other settings as required for your application. Ensure that each channel is correctly mapped and configured to match the connected devices.
  5. Testing: After installation and configuration, perform tests to verify that the module is functioning correctly. Check the output signals for accuracy and ensure that the connected devices respond as expected. Address any issues or discrepancies identified during testing.

Benefits of Using the TSXASY800 Analog Output Module

  1. Precision Control: The TSXASY800 provides high-resolution analog outputs, enabling precise control of various industrial processes and equipment. This precision enhances system performance and reliability.
  2. Versatility: With support for both current and voltage outputs, the module can interface with a wide range of devices and control systems. This versatility makes it suitable for diverse applications.
  3. Reliability: The module’s electrical isolation and diagnostic features contribute to its reliability and durability, ensuring stable performance even in challenging environments.
  4. Ease of Integration: Designed for compatibility with Modicon Premium PLCs, the TSXASY800 integrates easily into existing automation systems, reducing installation complexity and setup time.
  5. Improved Diagnostics: Built-in diagnostic tools allow for real-time monitoring and troubleshooting, helping to maintain smooth operation and minimize downtime.
  6. Enhanced Calibration: The module’s calibration and configuration options allow for tailored performance, ensuring that it meets the specific needs of different applications.

Conclusion

The TSXASY800 Analog Output Module is a valuable component for Modicon Premium PLC systems, offering precise and versatile analog output capabilities. Its high resolution, support for multiple output ranges, and reliable performance make it suitable for a wide range of industrial, commercial, and research applications. By facilitating accurate control and monitoring, the TSXASY800 enhances system efficiency and operational effectiveness, making it an essential tool in modern automation systems.