Description

With displayNo
Voltage type for actuatingAC/DC
Rated operating voltage Ue200 V
Rated control supply voltage at AC 50 Hz100 V
Rated control supply voltage at AC 60 Hz100 V
Overload current8.3 A
Controller typeSMC-3
DV/DT protection1000V/µs for power circuit.
Repetitive peak voltage1400V per UL, CSA, or NEMA for power circuit.
Operating frequency50/60 Hz per UL/CSA/NEMA for power circuit.
Line-connected motor power, max7.5…15 Hp @ 460V AC, 60 Hz, 3-phase.
Delta-connected motor power, max7.5…20 Hp @ 460V AC, 60 Hz, 3-phase.
Overvoltage categoryIII per IEC for side-mount auxiliary contacts.
Rated impulse voltage6 kV for power circuit.
Dielectric withstand2500V AC per IEC for power circuit.
Line-connected motor current9.2…25 A @ 380/400/415/460V AC, 3-phase.
Delta-connected motor current14.3…43 A @ 380/400/415/460V AC, 3-phase.
Insulation voltageRated 600V AC per UL/CSA/NEMA for power circuit.
Rated operational voltage250V AC/30V DC per UL/CSA/NEMA for side-mount auxiliary contacts.
Rated control power during start of the fan215 mA @ 120V AC, 180 mA @ 240V AC, 800 mA @ 24V DC, and 660 mA @ 24V AC.
Input OFF-state current<10 mA, <12 mA at the input OFF-state voltage (IN1, IN2) for control circuit.
Short-circuit protection device listNon-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L.
Number of contactsTB-97, -98 (OVLD/Fault): 1 for auxiliary contacts.
High capacity available fault current, max70 kA at 600 volts, maximum current 90 A time delay. Class J or Class L fuse for inside delta-connected motors.
Type of currentTB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith)TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuitTB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts.
Types of contactsTB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts.
Utilization categoryTB-23, -24 (normal/up-to-speed), TB-33, -34. (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts.
Rated operational current, maxTB-97, -98 (OVLD/Fault): 0.6 A @ 120V AC and 0.3 A @ 240V AC for auxiliary contacts.
Standard controller featureSoft stop
Standard available fault current, max5 kA @ maximum standard fuse 150 A for delta device operational current rating.
Integrated motor overload protectionYes
Short-circuit protection device performance (SCPD) typeType 1.
Selectable overload trip classTrip Class 10, 15, or 20.
Selectable start times2, 5, 10, 15, 20, 25, or 30 s.
Input OFF-state voltage (IN1, IN2), max40V AC, 17V DC, and 12V AC for control circuit.
Selectable current limit150%, 250%, 350%, and 450% of full load current.
Input ON-state voltage during start (IN1, IN2)85V AC, 19.2V DC, and 19.2V AC minimum for control. circuit.
Rated control power during start without fan205 mA @ 120V AC, 145 mA @ 240V AC, 705 mA @ 24V DC, and 580 mA @ 24V AC.
Input ON-state current (IN1, IN2)9.8 mA @ 120V AC/19.6 mA @ 240V AC for the control circuit, and 7.3 mA @ 24V AC/DC for the control circuit.